Tanda TX7223 Installation And Operation Manual

Addressable 12in/2out module

Advertisement

Quick Links

TX7223
Addressable 12in/2out module
Installation and Operation Manual
TANDA UK Technology Copyright ©2015, All right reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TX7223 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tanda TX7223

  • Page 1 TX7223 Addressable 12in/2out module Installation and Operation Manual TANDA UK Technology Copyright ©2015, All right reserved.
  • Page 2 TX7223 Addressable 12in/2out module Installation & Operation Manual Product Safety To prevent severe injury and loss of life or propert y, read the instruction carefully before installing the module to ensure proper and safe operation of the system. European Union directive...
  • Page 3: Table Of Contents

    TX7223 Addressable Multi I/O Module Installation & Operation Manual Table of Content 1 Introduction ............................4 1.1 Ov erview ............................. 4 1.2 Feature and Benefits ......................... 4 1.3 Technical Specification......................4 2 Installation............................4 2.1 I nstallation Preparation ......................4 2.2 I nstallation and wiring........................
  • Page 4: Introduction

    1 Introduction 1.1 Overview TX7223 Addressable 12in/2out module (hereinafter referred to as module) is a dedicated bus module device for fire protection, which can be connected with intelligent fire alarm controller. This module is easy to install, and has passive output port and input port. Input port has a strong analytical ability to judge the input port for open circuit and supervisory, and through the lights indicate the status.
  • Page 5 TX7223 Addressable Multi I/O Module Installation & Operation Manual Figure 1 module outline diagram 2. Bus line use RVS-2×1.0mm² or 1.5mm² Power line use RVVP-2×1.5 mm² or 2.0mm². Feedback Res 1/4W 5. 1K± 5% for every input port +IN12- +IN11-...
  • Page 6: Interface Module Configuration

    TX7223 Addressable Multi I/O Module Installation & Operation Manual Z1、Z2:Bus port D1、D2:DC power supply port NC、COM、NO:Passive output port IN+、IN-:Input port 3 Interface Module Configuration 3.1 Preparation The TX7930 handheld programmer is used to configure interface module soft address and parameter. This tool is not included, must be purchased separatel y. The programmer is packed with twin 1.5V AA battery and cable, ready for usage once received.
  • Page 7: Feedback Mode

    TX7223 Addressable Multi I/O Module Installation & Operation Manual Address: 001 Address: 001 1. Read Next Address: 003 2. Write 3. R/W Config 4. Set Success Fail Figure 4 Figure 5 Figure 6 3.3 Feedback Mode Input port default self feedback, non configurable.
  • Page 8: Troubleshooting Guide

    TX7223 Addressable Multi I/O Module Installation & Operation Manual respond to a fire condition and will void the manufacturer’s warranty. 4. Notify again proper personnel after conducting the maintenance and make sure to enable the interface module and confirm if up and running.