THE POWER CORD ON THIS APPLIANCE IS EQUIPPED
WITH A THREE PRONGED (GROUNDING) PLUG WHICH
MATES WITH STANDARD THREE PRONGED (GROUNDING)
WALL RECEPTACLES
PLUG
LINE
1/4 WIDE BLADE
GROUND
ROUND BLADE
BLK
CONNECT
.250 TERMINALS
BLK
(NOT USED)
(NOT USED)
VALVE
SWITCHES
SWITCHES ON VALVES
ELECTRIC CIRCUIT
CLOSED WHEN KNOB IS
ROTATED 55° TO 95°
COUNTER CLOCKWISE
FROM OFF
Caution: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
THE POWER CORD ON THIS APPLIANCE IS EQUIPPED
WITH A THREE PRONGED (GROUNDING) PLUG WHICH
MATES WITH STANDARD THREE PRONGED (GROUNDING)
WALL RECEPTACLES
PLUG
LINE
1/4 WIDE BLADE
GROUND
ROUND BLADE
GRN OR GRN/Y
BLK
CONNECT
WHT
.250 TERMINALS
BLK
VALVE
SWITCHES
SWITCHES ON VALVES
ELECTRIC CIRCUIT
CLOSED WHEN KNOB IS
ROTATED 55° TO 95°
COUNTER CLOCKWISE
FROM OFF
Caution: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Part No. 3191827 Rev. B
©2000 Whirlpool Corporation
120 VAC 60 Hz
1 PHASE
NEUTRAL 5/16
15 OR 20 AMP
WIDE BLADE
GRN OR GRN/Y
GROUND
WHT
WHT
MODULE
IGNITOR
ELECTRODES
120 VAC 60 Hz
1 PHASE
NEUTRAL 5/16
15 OR 20 AMP
WIDE BLADE
GROUND
WHT
WHT
BLK
SPARK
MODULE
IGNITOR
ELECTRODES
Benton Harbor, Michigan 49022
LINE
1/4 WIDE BLADE
GROUND
ROUND BLADE
CONNECT
SPARK
.250 TERMINALS
BLK
YEL OR
BRN
LINE
1/4 WIDE BLADE
GROUND
ROUND BLADE
CONNECT
.250 TERMINALS
BLK
YEL OR
BRN
(6) PLACES
THE POWER CORD ON THIS APPLIANCE IS EQUIPPED
WITH A THREE PRONGED (GROUNDING) PLUG WHICH
MATES WITH STANDARD THREE PRONGED (GROUNDING)
WALL RECEPTACLES
PLUG
NEUTRAL 5/16
WIDE BLADE
GRN OR GRN/Y
BLK
WHT
WHT
VALVE
SWITCHES
SWITCHES ON VALVES
ELECTRIC CIRCUIT
CLOSED WHEN KNOB IS
ROTATED 55° TO 95°
IGNITOR
COUNTER CLOCKWISE
FROM OFF
ELECTRODES
Caution: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
THE POWER CORD ON THIS APPLIANCE IS EQUIPPED
WITH A THREE PRONGED (GROUNDING) PLUG WHICH
MATES WITH STANDARD THREE PRONGED (GROUNDING)
WALL RECEPTACLES
PLUG
NEUTRAL 5/16
WIDE BLADE
GRN OR GRN/Y
BLK
GRN OR GRN/Y
BLK
WHT
VALVE
SWITCHES
YEL OR
BRN
SWITCHES ON VALVES
(5) PLACES
ELECTRIC CIRCUIT
CLOSED WHEN KNOB IS
ROTATED 55° TO 95°
COUNTER CLOCKWISE
IGNITOR
FROM OFF
ELECTRODES
Caution: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
120 VAC 60 Hz
1 PHASE
15 OR 20 AMP
GROUND
SPARK
MODULE
YEL OR
BRN
(4) PLACES
120 VAC 60 Hz
1 PHASE
15 OR 20 AMP
GROUND
SPARK
GROUND
MODULE
1
N
2
L1
3
GND
5
4
Printed in U.S.A.