Download Print this page

Important Safety Instructions - Kenmore 4123 - Elite 30 in. Electric Cooktop Installation Instructions Manual

Installation instructions
Hide thumbs Also See for 4123 - Elite 30 in. Electric Cooktop:

Advertisement

Available languages

Available languages

important
Notes
to the
Installer
1.
Read all instructions contained in these installation
instructions before installing the cooktop.
2.
Remove all packing material before connecting the
electrical supply to the cooktop.
3.
Observe all governing codes and ordinances.
4.
Be sure to leave these instructions with the consumer.
Important
Note
to the
Consumer
Keep these instructions with your Use and Care Guide for
future reference.
IMPORTANT
SAFETY
INSTRUCTIONS
• Be sure your cooktop
is installed
and grounded
properly
by a qualified
installer
or service
technician.
• These cooktops
must be electrically
grounded
in
accordance
with
local codes or, in their absence,
with the National
Electrical
Code ANSI/NFPA No.
70--latest
edition
in the United States, or with
CSA Standard
C22.1, Canadian
Electrical
Code,
Part 1, in Canada.
_The
electrical
power
to the cooktop
must be shut off while
line connections
are being
made. Failure to do so could result in serious injury
or death.
Provide
Electrical
Connection
Install the junction box under the cabinet and run 120/
240 or 120/208 Volt, AC wire from the main circuit
panel. DO NOT connect the wire to the circuit panel at
this time.
Electrical
Requirements
Observe all governing
codes and local ordinances.
1.
A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line
(time-delay fuse or circuit breaker is recommended).
DO NOT fuse neutral.
2.
A circuit breaker of 40 Amp is recommended.
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70-
latest edition,
and local codes and ordinances.
An extension
cord must not be used
with this appliance.
Such use may result in a fire,
electrical
shock, or other
personal
injury.
3.
The appliance should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible
armored cable extending from this appliance should
be connected directly to the grounded junction box.
The junction box should be located as shown in
Figure 2 with as much slack as possible remaining in
the cable between the box and the appliance, so it
can be moved if servicing is ever necessary.
4.
A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
Unpacking
Instructions
,
2.
//
,,
//
and Serial Plate
rlgr"-ure3 (UnderCooktop)
Leave corner supports on cooktop until completion
of Electrical Connection.
Be sure the bottle of cleaner conditioner packed in
the literature bag is left where the user can find it
easily. It is important
that the ceramic-glass
smoothtop
be pretreated before use. See Cooktop
Cleaning
and Maintenance
section in the Use
and Care Guide.
3

Advertisement

loading

This manual is also suitable for:

4123 30