CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE CONTENTS A - SAFETY INSTRUCTIONS 11.4 - Emergency stop parts 11.5 - Solar power kit 1 - OPERATING PRECAUTIONS D - BEGINNING OPERATION 2 - INSTALLATION PRECAUTIONS 3 - MAINTENANCE AND CLEANING 1 - SETTINGS INTERFACE 4 - RECYCLING 2 - QUICK SETTINGS B - PRODUCT DESCRIPTION...
Page 3
creating an account 1 - MAINTENANCE WORK 4.2 - Connecting the contactor 2 - OPERATING INDICATORS 4.3 - Usage via the application 3 - BATTERY VOLTAGE (FOR OPTIONAL SOLAR POWER KIT) 4.4 - Using the product with Google Home 36 4 - ANOMALY GUIDE 4.4.1 - If you have an Android smartphone with Google Assistant...
Avidsen cannot be held liable for any use that does This automatic gate opening mechanism, and not comply with the instructions in this manual and its manual, were designed to enable a gate to be causes damage.
Keep the remote controls out of the reach of children. This symbol means that devices no longer The Avidsen company shall not be responsible in use should not be disposed of with in case of damage if installation is not household waste.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE B - PRODUCT DESCRIPTION 1 - KIT CONTENTS x 24 x 24 24 V geared motor Ø8 spring washer 50 cm rack and screws Photocells and their screws Flashing light and screws Disengagement label Remote control Installation template Release key...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION HAZARD ANALYSIS SAFETY CHECKS ON THE GATE REGULATION • The guide rail must be perfectly straight, horizontal and fastened correctly to the ground. Installation of a motorised gate or a motor drive on •...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION Grille, net or safety edge Upper runner Clearance zone Rail Open end stop Close end stop SAFETY RULES The actual opening of a gate may create dangerous situations for people, goods and vehicles in the vicinity that by nature, cannot always be avoided by design.
Page 9
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION To avoid any risk of confinement in the gate clearance zone, the safety distances given in the diagram below must be observed. post gate stop 8 mm view from above P = 500 mm minimum if T is greater than 100 mm P = 200 mm minimum if T is less than 100 mm On the upper runners...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION opening. There are two solutions to remove this hazard: - Install a screen or net on the gate. The mesh must be no larger than 20 x 20 mm. - Install one or two safety edges on the post. grille or net safety edge 1 safety edge...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION Flashing light Attachment : page 15 Reception photocell Attachment: page 16 Transmission photocell Attachment: page 16 opening direction Rack Geared motor Attachment : page 13 Attachment : page 11 inner side of the property •...
Page 12
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION Post Post 15 mm Gate Gate 15 mm 5.5 cm 5.5 cm Post Template Template Foundation Foundation view from above The cable run between must comply with applicable standards (NFC 15-100). Either the cable is 80 cm deep with red warning mesh, or the cable is run through a sheath.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION When the motor is horizontal (adjust horizontality using the nuts under the motor), tighten the locknuts to block the clamp nut, then tighten the clamp nuts to keep the motor in position. Leave an air gap under the motor to prevent water from stagnating under the motor.
Page 14
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION ruler level 10mm 3 - INSTALLING THE FLASHING LIGHT The flashing light must be attached to the top of the pillar on which the motor unit is mounted, and it must be visible from both the inside and the outside.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION 4 - ATTACHING THE SET OF PHOTOCELLS Important notes: • The photocells must be perfectly aligned and parallel to each other. • The reception photocells (RX is indicated at the back) must be installed at the same side of the gate as the geared motor.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION 30 cm min 60 cm max outer side of the property perfect alignment 10 cm min/15 cm view from above outer side of the property Mounting: • Mount the photocells on the posts. •...
Page 17
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION Typical connection flashing light wired control part (contactor, motor intercom, etc.) 2 x 0.5 mm RX photocell 3 x 1.5 mm TX photocell Telephone cable 2 x 0.5 mm emergency stop part (punch button, safety edge, 2 set of photocells, etc.)
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION 6 - ELECTRONIC CONTROL CARD For ease of connection, all terminal blocks are removable. HALL 7 - MOTOR POLARITY The motor is already connected to the electronic card, but its connection direction depends on the direction in which the gate opens (“LR opening”, “RL opening”).
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION 9 - PHOTOCELLS Warning: Make the photocell connections when the actuator power is switched off. • Disconnect the removable terminal block, connect the photocell wires to the terminal block as shown in the diagram below and then reconnect the terminal block.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION 11 - OPTIONAL ACCESSORIES Set of photocells Backup Videophone battery additional 0.5 m rack Code keypad Additional remote control...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION 11.1 - ADDITIONAL PHOTOCELLS For use when the gate is not visible. You must install a second set of photocells to prevent the gate from opening when an item (car, person, etc.) is behind the gate. Installation The photocells must be perfectly aligned and parallel to each other.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION If using the STOP input, you must remove the connector between STOP and HALL Photocell Photocell NO COM NC Photocell Photocell NO COM NC 11.2 - ADDITIONAL CONTROL PARTS Gate control Pedestrian control HALL push-button,...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION 11.3 - EMERGENCY STOP PARTS The input for emergency stop parts is normally closed dry contact type. If no emergency stop part is installed, you must leave the connector closing the contact between STOP and GND. Examples of emergency stop parts: •...
Page 24
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE C - INSTALLATION the solar kit manual SET THE SWITCH TO 24V MOTORISATION BATTERY VOLTAGE SOLAR IN HALL batteries...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION 1 - SETTINGS INTERFACE All LEDs are turned off except the green LED • If the green LED is not lit, press PROG. Indicators - Lit up green LEDs are an error code (see paragraph “Event history and error code”).
Page 26
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION...
To find out more, please check out our tuto- • Press SET for 3 seconds and then, rials on our website • Press and hold “+” › the gate should open › www.avidsen.com/fr/assistance/tutoriel-sav release the button. • Press and hold “–” › the gate should close › Meaning release the button.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION 2.4 - PROGRAMMING REMOTE CONTROLS From a remote control that has already been memorised, you can memorise other remote You can control the complete or partial (pedestrian) controls (“copy” function). This is done by standing opening of the gate.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION it may be necessary to change the force of the • If you press a command during opening, it will not motors. be acknowledged. • If you press a command during the time delay, To adjust the force, follow the procedure below instead of cancelling the automatic closure, the •...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION If mode 1 (which is set by default) is the one desired • Press PROG again for 3 seconds. L0 will flash by the user, the user does not need to go to this twice, L1 will turn on and you will be in menu setting menu to re-enable mode 1, because the (advanced settings).
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION 3.2.1 - SPEED • Press SET to confirm this value › All the LEDs will turn on and off to confirm the operation. You can adjust the speed by a value of 0 to 5. To adjust this value, follow this procedure Time 78 cm 63 cm 47 cm 31 cm 23 cm 16 cm...
Full opening command remove all hazardous situations. Avidsen cannot be held liable for any installation or use that does not comply with the instructions and causes damage. It is essential to read the instructions carefully Partial opening command (opening 1.20 m)
CREATING AN ACCOUNT Once the contactor is connected, follow the instructions below to pair it. Download the Avidsen Home app from the Android Play Store or Apple App Store. Launch the app and log in if you already have an account.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION button for 5s so that the blue indicator light starts fl ashing. Select your 2.4GHz WiFi network (note: your smartphone must be connected to the WiFi network to which the plug will be connected), enter your network password and press suivant (next).
Page 35
(closed or not closed). Your contactor is now operational and will appear in your app. You can now control your Avidsen contactor from your smartphone. You can rename it by clicking on the small pencil to...
D - BEGINNING OPERATION 4.4 - USING THE PRODUCT WITH GOOGLE HOME Gate position status (display when in Note: the name you give your Avidsen Home operation) in relation to the magnets devices is the one that will be recognised by Google Assistant.
- In the Amazon Alexa app, press the menu at the top left and select Skills et Jeux (Skills and Games). - Search for Avidsen Home in the list of skills or use Recherche (Search) at the top right. - Select the Avidsen Home Skill and activate for use.
Amazon Alexa, contact Amazon support. 4.6 - SCENARIO AND AUTOMATION 4.6.1 - SCENARIO The scenario system in the Avidsen Home app allows you to group actions that will be triggered Name your scenario...
Page 39
The automation system in the Avidsen Home app allows you to group devices and actions which will be triggered automatically by the action of another device or a condition (temperature, time, etc.).
Page 40
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION • Quand toutes les conditions sont réunies (When all the conditions are met) corresponds to an “ET” (“AND”) function: - If Temperature = x ET (AND) time = y ET (AND) device = n then…...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION Once all these settings have been confirmed, you can save your automation at the top right Allows you to use a previously defined scenario (set of actions) Allows you to use a previously defined automation (automatic action) 4.6.3 - PROGRAMMING THE “GATE OPENING”...
Page 42
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION The first setting is stored. Now you must program the time. Click on +. Select the opening time. Slide your finger up or down the time column in the minute column. The time configured will appear between the two parallel lines.
Page 43
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE D - BEGINNING OPERATION Rename your scenario at your convenience (in Next you need to determine the action to be example: “OUVERTURE PORTAIL [GATE performed. OPENING”]) Once all parameters have been set, click on Save. If you wish to access the details or delete it, click on the “...”...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE E - USE Description of operation from the closed gate 2.2.3 - “COLLECTIVE” MODE position: Operation is identical to “automatic closure” mode, To open the gate except: • Activate the complete (or partial) opening •...
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE E - USE • Photocells can also be active at the beginning of the opening process (this is useful if a second set of photocells is installed – see “Advanced settings”). • If this is not the case and the beam is cut when the portal should start to open, the flashing light will emit double flashes for 30 seconds unless you activate a command.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE E - USE months: motor operation, photocells, control devices, etc. 2 - OPERATING INDICATORS This system has two operating indicators: the battery charge level (optional) and the event log. history of events delete log Battery charge 3 - BATTERY VOLTAGE (FOR OPTIONAL SOLAR POWER KIT)
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE F - MAINTENANCE AND UPKEEP 4 - ANOMALY GUIDE To find out more, please check out our tutorials on our website www.avidsen.com/fr/assistance/tutoriel-sav TYPE OF FAULT PROBABLE CAUSE WHAT YOU SHOULD DO When activating the opening...
Page 48
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE F - MAINTENANCE AND UPKEEP Meaning Type The emergency stop input has been activated A card power supply fault has been detected. It may be a short-circuit on the +12V output. Check the connections. An obstacle has been detected in the gate when opening.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE F - MAINTENANCE AND UPKEEP 4.1 - MANUAL CONTROL You can manoeuvre the gate with no programming, for example during installation, to check the opening direction is correct. • To enter manual mode, press “SET” for 3 seconds and LED L3 will fl ash.
The technical characteristics are provided as an indication only and for a temperature of +20°C. The company Avidsen reserves the right to modify these characteristics at any time, while under all circumstances guaranteeing these products’ smooth operation and the type of use intended, in an aim to improve these products.
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE G - TECHNICAL AND LEGAL INFORMATION REMOTE CONTROL Type: AM On/Off Keying (OOK) modulation. 16-bit Type Rolling code encoder (i.e. 65,536 possible combinations) Frequency 433.92 MHz Power supply 3V, CR2032 battery Keys 4 keys Radiated power <...
Page 52
CONNECTED MOTOR DRIVE KIT FOR SLIDING GATE G - TECHNICAL AND LEGAL INFORMATION HOMEGATE MODULE Max. power 200 W Features Opens gates and garage doors Wired Connection 1 output Cable cross-section Up to 1.5 mm Indoors and outdoors Operating temperature -10°C / +50°C Storage temperature -20°C / +70°C Power supply...
4 - PRODUCT RETURNS - AFTER SALES • The warranty will be void if the device is tampered SERVICE with. Avidsen undertakes to keep a stock of spare parts 3 - HELP AND ADVICE for this product throughout the contractual warranty period.
EN 301 489-1 V2.2.3 EN 301 489-3 V2.1.1 Avidsen declares, under its sole responsibility, that the remote control included in the 114461 kit complies with the applicable Union harmonisation legislation. Its conformity has been assessed pursuant to the applicable standards in force: - Directive RED 2014/53/EU EN 300 220-1 V3.1.1...