Wireless refillable ph tester for lab with built-in specialized electrode

Advertisement

Quick Links

INSTRUCTION MANUAL
HI9810462
Wireless Refillable pH Tester for Lab
with built-in specialized electrode
Hanna Instruments Inc., 584 Park East Drive, Woonsocket, RI 02895 USA
www.hannainst.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HALO2 HI9810462 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hanna Instruments HALO2 HI9810462

  • Page 1 INSTRUCTION MANUAL HI9810462 Wireless Refillable pH Tester for Lab with built-in specialized electrode Hanna Instruments Inc., 584 Park East Drive, Woonsocket, RI 02895 USA www.hannainst.com...
  • Page 2: Table Of Contents

    All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA. Hanna Instruments reserves the right to modify the design, construction, or appearance of its products without advance notice.
  • Page 3: Preliminary Examination

    Preliminary Examination 1. PRELIMINARY EXAMINATION Remove the tester and accessories from packaging and examine them carefully. For further assistance, ® please contact your local Hanna Instruments office or email us at tech@hannainst.com. Each HI9810462 is supplied with a starter kit consisting of: •...
  • Page 4: General Description & Intended Use

    3. GENERAL DESCRIPTION & INTENDED USE ® HI9810462 is a professional wireless pH tester, part of Hanna Instruments HALO2 family. • The integrated Bluetooth module allows the tester to be connected to a compatible smart device with the Hanna Lab App.
  • Page 5: Functional Description & Lcd Display

    Functional Description & LCD Display 4. FUNCTIONAL DESCRIPTION & LCD DISPLAY Front & Back view Setup Maximum immersion level ON/OFF pH sensitive button button bulb Recommended immersion HI9810462 Made in Romania Triple ceramic junction SN:XXXXXXXXX Battery cover Refill cap pH probe LCD display 1 Calibration indicator 6 Temperature compensation...
  • Page 6: Setup

    Setup 6. SETUP The Setup button is located inside the battery compartment. After Setup configuration, replace the cover. Setup Menu Navigation • Press the Setup button to enter Setup mode and navigate menu items. • To exit Setup mode, press the Setup button after “ SEt TIME ” option is displayed. •...
  • Page 7: Bluetooth

    Bluetooth 7. BLUETOOTH With “ PAIr BLU ” or “ On BLU ” selected in Setup, the Bluetooth icon ( & ) will blink for up to 45 seconds, indicating the tester is in discoverable mode. Once connected, the icon will stop blinking. If not connected, the icon is not displayed.
  • Page 8: Procedure

    Calibration Procedure For most applications it is recommended to start with pH 7.01 buffer (or pH 6.86). To restore factory defaults, press and hold the ON/OFF button. “ CAL CLR ” is displayed. Note: It is recommended to calibrate the electrode with buffers at the temperature it will be used at. Stand-Alone Tester (Up to Three-Point Calibration) 1.
  • Page 9: Care & Maintenance

    Care & Maintenance 10. CARE & MAINTENANCE • Never immerse the tester over the maximum immersion level. • Fresh buffers should be used for each calibration. Once the sachets are opened the buffer value can change over time. • If the electrode is slow or sluggish, soak it in cleaning solution for 20 minutes. Rinse with water and hydrate the electrode in storage solution for a minimum of 30 minutes before calibrating.
  • Page 10: Accessories

    Accessories 13. ACCESSORIES Ordering Information Product Description pH Buffer Solution HI50016-02 pH 1.68 buffer solution, 20 mL sachet (25 pcs.) HI70004P pH 4.01 buffer solution, 20 mL sachet (25 pcs.) HI70006P pH 6.86 buffer solution, 20 mL sachet (25 pcs.) HI70007P pH 7.01 buffer solution, 20 mL sachet (25 pcs.) HI70009P...
  • Page 11: Recommendations For Users

    If the repair is not covered by the warranty, you will be notified of the charges incurred. If the tester is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization (RGA) number from the Technical Service department and then send it with shipping costs prepaid.
  • Page 12: Certification

    Certification  CERTIFICATION ® All Hanna instruments conform to the CE European Directives and UK Standards. Disposal of Electrical and Electronic Equipment. The product should not be treated as household waste. Instead, hand it over to the appropriate collection point for the recycling of electrical and electronic equipment, which will conserve natural resources. Disposal of waste batteries.