1 Product overview ························································································ 1
2 Chassis views ····························································································· 1
IE4500-14S-G ···················································································································································· 1
IE4500-14S-UPWR-G ········································································································································ 3
3 Chassis dimensions ···················································································· 4
4 Installing the switch ····················································································· 5
Safety recommendations ··································································································································· 5
Checking power distribution or power supply environment ················································································ 6
Mounting the switch on a DIN rail ······················································································································ 6
DIN bracket and DIN rail ···························································································································· 6
Mounting the switch on a DIN rail ·············································································································· 7
Connecting the grounding cable ························································································································ 8
Connecting the grounding cable ················································································································ 8
Verifying the connection after grounding the switch··················································································· 9
Connecting power cords ···································································································································· 9
Connecting cables to the alarm input and alarm output connections and RS485 port ···································· 10
Verifying the installation ··································································································································· 11
Connecting a serial console cable ··················································································································· 11
Connecting a DB9-to-RJ45 console cable ······························································································· 12
Connecting a USB-to-RJ45 console cable ······························································································· 13
5 LEDs ········································································································· 15
6 Accessing the switch ················································································ 16
7 Technical specifications ············································································ 16
8 Available transceiver modules and cables ················································ 18
100/1000Base-X SFP port ······························································································································· 18
SFP+ port ························································································································································· 20
Contents
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IE4500-14S-G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for H3C IE4500-14S-G

  • Page 1: Table Of Contents

    Contents 1 Product overview ························································································ 1 2 Chassis views ····························································································· 1 IE4500-14S-G ···················································································································································· 1 IE4500-14S-UPWR-G ········································································································································ 3 3 Chassis dimensions ···················································································· 4 4 Installing the switch ····················································································· 5 Safety recommendations ··································································································································· 5 Checking power distribution or power supply environment ················································································ 6 Mounting the switch on a DIN rail ······················································································································...
  • Page 2: Product Overview

    Product overview H3C IE4500-G DIN-rail mount switch series includes the following models: • IE4500-14S-G—Provides eight 10/100/1000BASE-T copper ports, six 100M/1G/10GBASE-X SFP+ ports, and one 1-channel RS485 port. • IE4500-14S-UPWR-G—Provides eight 10/100/1000BASE-T PoE++ copper ports, six 100M/1G/10GBASE-X SFP+ ports, and one 1-channel RS485 port.
  • Page 3 (9) RS485 port (10) Alarm output connection (DO) (11) Alarm input connection (DI) Figure2-2 Top panel (1) Grounding screw (2) Power supply 1 (3) Power supply 2 (4) Reset button (RESET) (5) USB port (6) Console port (7) Management Ethernet port NOTE: To reboot the switch, press and hold the reset button for more than 5 seconds.
  • Page 4: Ie4500-14S-Upwr-G

    IE4500-14S-UPWR-G Figure2-3 Front panel (1) Diag LED (Diag) (2) Power supply 1 status LED (3) Power supply 1 status LED (4) Alarm LED (Alarm) (5) 10/100/1000BASE-T PoE++ copper port (6) 10/100/1000BASE-T PoE++ copper port LEDs (7) SFP+ port LED (8) SFP+ port (9) RS485 port (10) Alarm output connection (DO) (11) Alarm input connection (DI)
  • Page 5: Chassis Dimensions

    To reboot the switch, press and hold the reset button for more than 5 seconds. Chassis dimensions The IE4500-G DIN-rail mount switches have the same dimensions. The following uses the IE4500-14S-G switch as an example. Select an appropriate installation position for the switch based on its dimensions.
  • Page 6: Installing The Switch

    Figure3-1 Chassis dimensions Installing the switch WARNING! When you operate the switch, always wear an ESD wrist strap or ESD gloves and make sure they make good skin contact and are reliably grounded. Do not touch the components on the switch. Safety recommendations To avoid bodily injury or damage to the switch, read the following safety recommendations carefully before working with the switch.
  • Page 7: Checking Power Distribution Or Power Supply Environment

    • When installing the switch, always wear an ESD wrist strap. Make sure the wrist strap makes good skin contact and is reliably grounded. • Do not hot swap the terminal blocks. Checking power distribution or power supply environment Table4-1 Requirements for power distribution or power supply environment Item Requirements Preparation...
  • Page 8: Mounting The Switch On A Din Rail

    As shown by callout 1 in Figure4-3, position the switch so that the spring of the DIN bracket compresses against the upper edge of the DIN rail. As shown by callout 2 in Figure4-3, rotate the switch down toward the DIN rail until the DIN bracket clicks. Figure4-3 Mounting the switch on a DIN rail (IE4500-14S-G)
  • Page 9: Connecting The Grounding Cable

    Use a screwdriver to fasten the grounding screw into the grounding screw hole. Connect the other end of the grounding cable to the grounding point or grounding strip. Figure4-4 Connecting the grounding cable to the chassis (IE4500-14S-G) (1) Grounding screw...
  • Page 10: Verifying The Connection After Grounding The Switch

    12 AWG • IE4500-14S-UPWR-G Both the IE4500-14S-G and IE4500-14S-UPWR-G switches support DC power cord connection. The following uses the IE4500-14S-G switch as an example. To connect a DC power cord: Use a wire stripper to strip the heat-shrink tubes off the two-wire power cord on one end, and then strip the electrical insulation off to make sure about 7 mm (0.28 in) of the wire reaches out.
  • Page 11: Connecting Cables To The Alarm Input And Alarm Output Connections And Rs485 Port

    The switch provides an alarm input connection, an alarm output connection, and an RS485 port on the front panel. The following uses the IE4500-14S-G switch as an example. To connect cables to the alarm input and alarm output connections and RS485 port:...
  • Page 12: Verifying The Installation

    As shown by callout 3 in Figure4-6, connect the terminal block to the switch. Connect the other ends of the wires to external devices. Figure4-6 Connecting cables to the alarm input and alarm output connections and RS485 port (IE4500-14S-G) Verifying the installation After you complete the installation, verify the following information: •...
  • Page 13: Connecting A Db9-To-Rj45 Console Cable

    To avoid abnormal configuration terminal display, use the recommended H3C DB9-to-RJ45 console cable (part number: 04042967) or H3C USB-to-RJ45 console cable (part number: 0404A1EE). To prepare a serial console cable yourself, make sure the signal pinout for the RJ-45 connector is the same as that shown in Table4-6.
  • Page 14: Connecting A Usb-To-Rj45 Console Cable

    A DB9-to-RJ45 serial console cable is an 8-core shielded cable, with a crimped RJ-45 connector at one end for connecting to the serial console port of the switch, and a DB-9 female connector at the other end for connecting to the serial port on a configuration terminal. Figure4-8 DB9-to-RJ45 console cable Table4-6 DB9-to-RJ45 console cable signal pinout RJ-45...
  • Page 15 Click the following link, or copy it to the address bar on your browser and download the USB-to-RJ45 console driver. http://www.h3c.com/en/home/USB_to_RJ45_Console/ View the Read me.txt file in the Windows folder to identify whether the Windows system of the configuration terminal supports the driver.
  • Page 16: Leds

    Figure4-11 Finishing the driver installation Connect the standard USB connector of the cable to the USB port of the configuration terminal. Connect the RJ-45 connector of the cable to the console port on the switch. LEDs Table5-1 LED description Mark Status Description A power cord has been connected to the power...
  • Page 17: Accessing The Switch

    • Parity—None. • Flow control—None. Technical specifications Table7-1 Technical specifications Item IE4500-14S-G IE4500-14S-UPWR-G Dimensions (H × W × D) 155 × 103 × 135 mm (6.10 × 4.06 × 5.32 in) ≤ 2.2 kg (4.85 lb) Weight Console port 10/100/1000BASE-T...
  • Page 18 Item IE4500-14S-G IE4500-14S-UPWR-G USB port RS485 port Management Ethernet port The system detects exceptions of the connected device based on the input voltage changes on the alarm input connection. • State: Alarm input connection 1: 13 V to 30 V ...
  • Page 19: Available Transceiver Modules And Cables

    Available transceiver modules and cables 100/1000Base-X SFP port Table8-1 Non-industrial transceiver modules available for the 100/1000Base-X SFP ports Mode Cable Central bandwi Transmis Transceiver Connector type and Transmis wavelength sion module model type diameter sion rate (nm) (MHz*k distance (µm) Category 100 m SFP-GE-T-D...
  • Page 20 Mode Cable Central Transmis bandwi Transceiver Connector type and Transmis wavelength sion module model type diameter sion rate (nm) (MHz*k distance (µm) 490-BIDI-I (6.21 Rx: 1310 miles) SFP-GE-LX-SM1 490-BIDI-S SFP-GE-LX-SM1 310-BIDI 10 km Tx: 1310 SFP-GE-LX-SM1 9/125 µm, (6.21 1250 Mbps 310-BIDI-S Rx: 1490 miles)
  • Page 21: Sfp+ Port

    Table8-2 Industrial transceiver modules available for the 100/1000Base-X SFP ports Mode Cable Central bandwi Transmis Transmi Transceiver Connector type and wavelength sion ssion module model type diameter (nm) (MHz*k distance rate (µm) Category 100 m SFP-GE-T-I RJ-45 1250 Mbps 5e twisted (328.08 ft) pair cable 40 km...
  • Page 22 Mode Interface Central bandwi Transmis Transceiver Connector cable Transmis wavelength sion module model type specifica sion rate (nm) (MHz*k distance tions 50-D (1312.34 ft) SFP-XG-SX-MM8 300 m 2000 50-E (984.25 ft) SFP-XG-SX-MM8 82 m 50-S (269.03 ft) SFP-XG-SX-MM8 50-A 66 m (216.54 ft) 33 m (108.27 ft)
  • Page 23 Mode Interface Central bandwi Transmis Transceiver Connector cable Transmis wavelength sion module model type specifica sion rate (nm) (MHz*k distance tions SFP-XG-LX-SM1 10 km 270-BIDI Tx: 1270 9/125 µm, (6.21 10.31 Gbps SFP-XG-LX-SM1 Rx: 1330 miles) 270-BIDI-S SFP-XG-LX-SM1 10 km 330-BIDI Tx: 1330 9/125 µm,...
  • Page 24 Mode Interface Central Transmis bandwi Transceiver Connector cable Transmis wavelength sion module model type specifica sion rate (nm) (MHz*k distance tions miles) Table8-6 Non-industrial cables available for the SFP+ ports Cable model Cable length Transmission rate LSWM1STK 0.65 m (2.13 ft) LSWM2STK 1.2 m (3.94 ft) 10.31 Gbps...

This manual is also suitable for:

Ie4500-14s-upwr-g

Table of Contents