Daikin DC96VC User's Information Manual
Daikin DC96VC User's Information Manual

Daikin DC96VC User's Information Manual

Gas-fired warm air furnace

Advertisement

Quick Links

GAS-FIRED WARM AIR FURNACE
Installer - Affix this manual, Installation Guide, and Warranty adjacent to the appliance.
Owner - Read and keep all product literature in a safe place for future reference.
S
HOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL
,
TO SHUT OFF
TURN OFF THE MANUAL GAS SHUTOFF VALVE
EXTERNAL TO THE FURNACE BEFORE TURNING OFF THE
.
ELECTRICAL SUPPLY
HID-2004
7/2014
USER'S INFORMATION MANUAL
U
'
SER
S
I
F THE INFORMATION IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY
CAUSING PROPERTY
D
O NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE
D
O NOT TRY TO LIGHT ANY APPLIANCE
D
O NOT TOUCH ANY ELECTRICAL SWITCH
ANY PHONE IN YOUR BUILDING
I
MMEDIATELY CALL YOUR GAS SUPPLIER FROM A
'
NEIGHBOR
S PHONE
INSTRUCTIONS
I
F YOU CANNOT REACH YOUR GAS SUPPLIER
FIRE DEPARTMENT
I
NSTALLATION AND SERVICE MUST BE PERFORMED BY A
QUALIFIED INSTALLER
WARNING
P
RODUCT CONTAINS FIBERGLASS WOOL
INSULATION IN THIS PRODUCT DURING INSTALLATION
MAINTENANCE OR REPAIR WILL EXPOSE YOU TO
FIBERGLASS WOOL
. (F
CANCER
IBERGLASS WOOL IS KNOWN TO THE
C
ALIFORNIA TO CAUSE CANCER
OR FOR FURTHER INFORMATION
SAFETY DATA SHEETS AVAILABLE FROM THE ADDRESS
.
SHOWN BELOW
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
Our continuing commitment to quality products may mean a change in specifications without notice.
© 2014
5151 San Felipe St., Suite 500, Houston, TX 77056
I
M
NFORMATION
WARNING
,
A FIRE OR EXPLOSION MAY RESULT
.
.
.
. F
OLLOW THE GAS SUPPLIER
.
.
,
SERVICE AGENCY OR THE GAS
T
O PREVENT POSSIBLE PROPERTY DAMAGE
INJURY OR DEATH DUE TO ELECTRICAL SHOCK
FURNACE MUST BE LOCATED TO PROTECT THE ELECTRICAL
COMPONENTS FROM WATER
WARNING
. D
. B
REATHING THIS MAY CAUSE LUNG
.) T
O REDUCE EXPOSURE
,
CONSULT MATERIAL
www.daikincomfort.com
ANUAL
;
DO NOT USE
'
S
,
CALL THE
WARNING
.
ISTURBING THE
,
S
TATE OF
,
PERSONAL
,
THE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DC96VC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin DC96VC

  • Page 1 USER’S INFORMATION MANUAL GAS-FIRED WARM AIR FURNACE ’ NFORMATION ANUAL WARNING F THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY O NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE •...
  • Page 2: Table Of Contents

    Contents ................3 MPORTANT OTE TO THE WNER REGARDING RODUCT ARRANTY ..............................3 OCATION ............................. 4 NSTALLATION Air Requirements ............................... 4 Combustion Air ..............................4 Indoor Humidity ..............................5 Propane (LP) Gas Installations Only ........................ 5 ............................. 5 HERMOSTAT UNCTIONS Furnace Operation .............................
  • Page 3: Mportant Ote To The Wner Regarding Roduct Arranty

    Dear Homeowner, please recognize the following safety in- 2. Do not store or use chlorine or fluorine products (bleaches, formation. This information will alert you to the potential for cements, strippers, aerosols) near the unit. They can cor- personal injury. rode the heat exchanger.
  • Page 4: Air Requirements

    1. Headaches, Nausea, Dizziness, Flu-like symptoms. EQUIREMENTS 2. Excessive humidity, heavily frosted windows or a moist “clammy” feeling in the home. WARNING 3. Smoke from a fireplace will not draw up the chimney. O AVOID PROPERTY DAMAGE PERSONAL INJURY OR DEATH SUFFICIENT FRESH AIR FOR PROPER COMBUSTION 4.
  • Page 5: Thermostat Functions

    RECOMMENDED TO CONTACT A PROPANE SUPPLIER TO fan runs all the time. INSTALL A GAS DETECTING WARNING DEVICE IN CASE OF A GAS LEAK If this furnace is a part of the Daikin ComfortNet™ family of • INCE PROPANE GAS IS HEAVIER THAN AIR ANY LEAKING...
  • Page 6: Furnace Shut Down

    5. This furnace is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 6. Move the furnace’s gas valve ON/OFF switch to the OFF position. 7. Wait five minutes to clear out any gas. Then smell for gas, including near the floor as some types of gas are heavier than air.
  • Page 7: Routine Maintenance

    • Drainage system. Check for blockage and/or leakage. OUTINE AINTENANCE Check hose connections at and internal to furnace. Maintenance is to be performed by a qualified service tech- • Filters. Check that filters are clean and in the proper nician only. User maintenance is to be restricted to frequent placement in the furnace or duct system.
  • Page 8: Troubleshooting / Before You Request A Service Call

    To remove all other filter configurations, consult with the in- • Check to see that the manual gas shut-off valve exter- stalling contractor. nal to the furnace is in the ON position. If the valve is in the OFF position, turn the gas ON following the start up procedures outlined in the “Furnace Start-up”...
  • Page 9: Safety Labels

    AFETY ABELS NOTE: If safety labels are missing or illegible, contact the installing dealer or our Customer Service Department for ordering information.
  • Page 10 AFETY ABELS WARNING RISK OF ELECTRIC SHOCK. CAN CAUSE INJURY OR DEATH: DISCONNECT ALL REMOTE ELECTRIC POWER SUPPLIES BEFORE SERVICING. THIS COMPARTMENT MUST BE CLOSED EXCEPT WHEN SERVICING. AVERTISSEMENT DANGER DE CHOC ELETRIQUE OU DE MORT. COUPEZ TOUT LE COURANT AVANT TOUT ENTRETIEN OU REPARATION. LE COMPARTEMENT DOIT RESTER FERMER SAUF PENDANT LENTRETIEN.
  • Page 11 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 12 Most questions can be answered by your local dealer. For additional information, please call: CONSUMER INFORMATION LINE TOLL FREE 1-855-770-5678 (U.S. only) email us at: customerservice@daikincomfort.com fax us at: (731) 856-1821 (Not a technical assistance line for dealers.) Outside the U.S., call 1-713-861-2500. (Not a technical assistance line for dealers.) Your telephone company will bill you for the call.

This manual is also suitable for:

Dm96vcDm80vcDc97mcDm97mcDc80vc

Table of Contents