Tumble Dryers 30 Pound (13 Kilogram) Capacity 35 Pound (16 Kilogram) Capacity Stacked 30 Pound (13/13 Kilogram) Capacity Stacked 45 Pound (20/20 Kilogram) Capacity 55 Pound (24 Kilogram) Capacity 18 Digit Model Numbers with 6 in 13th Position Refer to Page 12 for Model Identification TMB1292C_SVG Original Instructions Keep These Instructions for Future Reference.
Page 3
This specific regulatory information for tumble dryer installa- WARNING tion and operation must be followed. Installation must conform with local codes or, in the absence • Do not store or use gasoline or other flammable of local codes, with: vapors and liquids in the vicinity of this or any In the U.S.A., installation must conform to the latest edition of other appliance.
Page 4
CAUTION WARNING To reduce the risk of electric shock, fire, explosion, Electrical shock hazard can cause death or serious Electrical shock hazard can cause death or serious serious injury or death: injury. injury. To reduce the risk of electric shock, •...
• A “T-Handle” type gas shut-off valve must be installed in WARNING the gas supply line to this appliance. • This appliance must not be installed in a bedroom or bath- In Australia and New Zealand: room. • DO NOT modify this appliance. Regulatory Statements •...
Page 6
No Alliance Laundry Systems products comply with the require- changes are authorized to the radio or the antenna of the ap- ment of Article 12 as it can be operated in at least one Member proved device.
vices is subject to the conditions that no harmful interference is The information in this section applies to products approved caused. The user must stop operating the device immediately by the Thailand National Communications Commission: should harmful interference is caused and shall not resume un- These telecommunication and device are compliance with the til the condition causing the harmful interference has been cor- requirements of National Broadcasting and Telecommunica-...
China Restriction of hazardous substances (RoHS) China Restriction of hazardous substances (RoHS) The Table of Hazardous Substances/Elements and their Content As required by China’s Management Methods for Restricted Use of Hazardous Substances in Electrical and Electronic Products Hazardous substances Part Name Lead Mercury Cadmium...
Safety Information Safety Information Important Safety Instructions • Do not tumble fiberglass curtains and draperies unless the la- bel says it can be done. If they are dried, wipe out the cylin- der with a damp cloth to remove particles of fiberglass. WARNING •...
Safety Information • Tumble dryer will not operate with lint panel open. DO NOT manufacturer about any problems or conditions you do not un- bypass lint panel door safety switch to permit the tumble derstand. dryer to operate with the lint panel door open. NOTE: All appliances are produced according to the •...
Cabinet Dimensions – 030, S30, 035 and 055 Series ................26 Cabinet Dimensions – T30 and T45 Series...................27 Exhaust Outlet Locations – 030, S30, 035 and 055 Series ..............28 Exhaust Outlet Locations – T30 and T45 Series...................29 Gas Connection Locations – 030, S30, 035 and 055 Series..............30 Gas Connection Locations –...
Page 12
Venting ..............................44 Individual Venting..........................45 Manifold Venting ..........................46 Gas Requirements Gas Requirements ................................................49 49 Gas Requirements ..........................49 How to Change Burner Orifice Size ....................54 How to Adjust Gas Valve Governor/Regulator .................55 Installing CE Gas Tumble Dryer......................57 Adjusting Manifold Pressure for Natural Gas G20 or G25..............57 Adjusting Supply Pressure for L.P.G.
Introduction Introduction Machine Identification Information in this manual is applicable to these machines. Refer to the serial plate. 030 Series (30 lb / 13 Kg) BA030E BU030E HA030E HT030N NH030E PJ030N SJ030D UG030L BA030L BU030F HA030L HU030E NH030N PK030E SJ030E UG030N BA030N BU030N...
Page 19
Introduction source from which you purchased your unit. WARNING When calling or writing about your unit, PLEASE GIVE THE MODEL AND SERIAL NUMBERS. The model and serial To reduce the risk of serious injury or death, DO numbers are located on the serial plate. The serial plate will be NOT repair or replace any part of the unit or attempt in the location shown in Figure 1 .
Specifications and Dimensions Specifications and Dimensions Refer to machine serial plate for additional specifications. Specifications 030 Series S30 Series 035 Series 055 Series Weights and Shipping Information Net Weight (approxi- Gas 335 [150] Standard Gas 340 Gas 365 [165] Gas 440 [200]...
Page 21
Specifications and Dimensions Specifications 030 Series S30 Series 035 Series 055 Series Cylinder Size Cylinder Size: 26.5 x 30.0 [673 x 762] 26.0 x 30.0 [660 x 30.0 x 30.0 [762 x 762] 33.0 x 35.0 [838 x 889] 762]...
Page 22
Specifications and Dimensions Specifications 030 Series S30 Series 035 Series 055 Series Noise level measured 59 dBA Standard Model 63 61 dBA 61 dBA during operation at op- erator position of 3.3 ProCapture Model feet [1 meter] in front of 64 dBA machine and 5.2 feet...
Page 23
Specifications and Dimensions NOTE: All IEC machines are shipped with an adapter to convert the gas connection threads to BSPT (from NPT). Specifications T30 Series T45 Series Weights and Shipping Information Net Weight (approximate): Standard Gas 580 [265] 690 [315] Pounds [kg] ProCapture Gas 620 [280] Electric 605 [275]...
Page 24
Specifications and Dimensions Specifications T30 Series T45 Series Drive Motor (per pocket): Horsepower 0.5 [0.4] 0.5 [0.4] [kW] Fan Motor (per pocket): Horsepower 0.5 [0.4] 0.5 [0.4] [kW] Air Outlet Diameter: Inch [mm] Standard Model (elliptical) Standard Model 8.0 [200] 10.0 [250] Eco Model (round) Eco Model...
Page 25
Specifications and Dimensions Specifications T30 Series T45 Series Gas Burner Rating (per pocket): Standard Model Standard Model BTU/hr. [kW, Mj/hr.] 73,000 [21.4, 77.0] 95,000 [27.8, 100.2] ProCapture Model Eco Model 68,000 [19.9, 71.7] 80,000 [23.4, 84.4] Eco Model 55,000 [16.1, 58.0] Gas Burner Rating (total machine): Standard Model Standard Model...
Specifications and Dimensions Exhaust Outlet Locations – 030, S30, 035 and 055 Series TMB2724N_SVG Models Rear Exhaust Dimensions, in. [mm] Diameter 030 Series Standard Model Eco Model 3.9 [100] 4.6 [115] 6.0 [150] 6.0 [150] S30 Series Standard Model ProCapture Model 3.9 [100]...
Specifications and Dimensions Gas Connection Locations – 030, S30, 035 and 055 Series TMB2726N_SVG 1. T and G Markets 1/2 NPT; All Other Markets 1/2 BSPT Models Gas Connection, in. [mm] 030 Series 54.2 [1,375] 1.5 [40] S30 Series 54.2 [1,375] 1.5 [40]...
Specifications and Dimensions Gas Connection Locations – T30 and T45 Series TMB2727N_SVG 1. A Market 1/2 BSPT; All Other Markets 1/2 NPT NOTE: Markets H, J, K, L, R and U have an NPT to BSPT adapter included with machine. Models Gas Connection, in.
Specifications and Dimensions Electrical Connection Locations – 030, S30, 035 and 055 Series TMB2728N_SVG 1. Gas and Steam Models: Electrical Connection 1.375 in. [22 mm] Diameter; Electric Models: Electrical Connection Diameter Models Electrical Service Dimensions, in. [mm] 030 Series 33.2 [845] 18.5 [470]...
Specifications and Dimensions Electrical Connection Locations – T30 and T45 Series TMB2729N_SVG 1. Gas Models: Electrical Connection 0.875 in. [22 mm] Diameter; Electric Models: Electrical Connection 1.375 in. [35 mm] Diame- 2. Electrical Connection 1.375 in. [35 mm] Diameter Models Electric Service Dimensions, in.
Installation Installation Pre-Installation Inspection Materials Required (Obtain Locally) Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is Steam Models One steam shut-off valve for steam ser- damaged or signs of possible damage are evident, have the vice line to be connected upstream of so- carrier note the condition on the shipping papers before the lenoid steam valve.
Installation If rear of machine or water supply is located in an area where it WARNING will be exposed to cold/freezing temperatures, provisions must be made to protect these water lines from freezing. To reduce the risk of severe injury, clearance of tumble dryer cabinet from combustible construction must conform to the minimum clearances, and/or local codes and ordinances.
Installation Fire Suppression System (Optional Equipment) WARNING ELECTRICAL SHOCK HAZARD. Electrical shock can result in death or serious injury. If the water T483I_SVG dispensing system is activated, do not attempt to Figure 3 operate the tumble dryer. If the water dispensing system is activated, have the tumble dryer inspected by a qualified agency before operating Fifth Leveling Leg...
Installation provisions must be made to protect these water lines from freezing. IMPORTANT: Temperature of the water supply must be kept between 4.5°C and 49°C [40°F and 120°F] . If water in the supply line or water solenoid valve freezes, the fire suppression system will not operate. IMPORTANT: If temperature sensors inside the tum- ble dryer register a temperature below 4.5°C [40F°] , the fire suppression system control will lock out.
To Reverse the Loading Door (030, Electrical power must be provided to tumble dryer at all times. The fire suppression system will be S30, 035 and 055 Series) inoperative if the main electrical power supply is disconnected. The tumble dryer is delivered with a right hinged door, but the door can be changed to a left hinged position.
Page 40
Installation TMB2101N_SVG 1. Plug 2. Switch TMB2607N_SVG 3. Door Hinge Lug 4. Door Assembly 1. Front Panel Screw 5. Side Screw 2. Front Panel 3. Control/Access Panel Figure 9 4. Control Assembly Screw 5. Control Assembly 7. Cut wire ties to remove door switch harness bundle. Be care- 6.
Installation TMB2609N_SVG 1. Switch (New location) 2. Plug (New location) 3. Door Assembly 4. Side Screw Figure 11 TMB2608N_SVG 1. Beginning Location of Door Switch NOTE: If machine is converted back to right hand 2. Wire Ties hinge operation, the door switch harness must be 3.
Installation IMPORTANT: The electronic ignition system will 9. Check the airflow switch operation by opening the lint panel; attempt to light the gas by sparking for the “trial if applicable, be sure to remove shipping wire tie from air- for ignition” period. If gas does not ignite within flow switch prior to operation.
Standard 030 Series; Stan- 110 [710] W773R1 dard and ProCapture S30 Se- ries WARNING Standard 035/055 Series 144 [930] To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumble dryer Eco 035 Series 120 [775]...
Exhaust Requirements Venting NOTE: Exhaust ducts must be constructed of sheet metal or other noncombustible material. Such ducts must be equivalent in strength and corrosion resis- WARNING tance to ducts made of galvanized sheet steel not less than 0.02 inches [0.50 mm] thick. To reduce the risk of fire due to increased static Where the exhaust duct pierces a combustible wall or ceiling, pressure, we do not recommend installation of third...
Exhaust Requirements TMB2361N_SVG TMB2362N_SVG TMB2426N_SVG 1. Removable strip of panel in framing wall to permit removal of tumble dryer from framing wall 2. Partition or bulkhead 3. Minimum distance between exhaust opening and roof, ground or other obstruction, 36 in. [910 mm] 4.
Exhaust Requirements cates minimum diameters, and should be increased if the col- Duct Diameter Equivalent Length of lector length exceeds 14 feet and two 90° elbows. The diame- Rigid Straight Duct ter of a round duct must be increased by 10% for each addi- tional 20 feet .
Page 47
Exhaust Requirements Duct Station Eco T30, 030 and Stan- ProCapture S30, 035, 055, T45 Series dard S30 Series Standard T30 and Pro- Capture T30 Series 6 in. [152 mm] 8 in. [203 mm] 10 in. [254 mm] 10 in. [254 mm] 12 in.
Gas Requirements Gas Requirements Gas Requirements IMPORTANT: The installation must comply with local codes or, in the absence of local codes: • with the latest edition of the “National Fuel Gas CAUTION Code,” ANSI Z223.1/NFPA 54 in the U.S.A. • with CAN/CSA-B149.1 Natural Gas and Propane In- •...
Page 50
Gas Requirements PROPANE/LIQUID PETROLEUM GAS (L.P.G.) supply pres- sures with all gas appliances running (tumble dryers, water heaters, space heaters, furnace, etc.): Maximum 10.5 in. w.c. Not Applica- Refer to Table 15 Nominal 6.5 in. w.c 1.13 kPa Maximum 13 in. w.c. Not Applica- Refer to (Recom-...
Page 51
Gas Requirements Burner Orifice Sizing Model Market Altitude Burner Orifice feet [meters] inches [mm] Part No. 030 Series A, G, H, J, K, T, Natural 0-2,000 [0-609] 0.1610 [4.09] 70684142 Eco Natur- 0-2,000 [0-609] 0.1405 [3.57] 70684134 al Gas A, G, K, L, T L.P.
Page 52
A, G, H, K, L, T L.P. Gas 0-2,000 [0-609] 0.1110 [2.82] 70684123 L.P. Gas 0-2,000 [0-609] 0.0995 [2.53] 70684117 055 Series A, G, H, J, K, T, Natural 0-2,000 [0-609] 0.1960 [4.98] 70684154 Eco Natur- 0-2,000 [0-609] 0.1910 [4.85]...
Gas Requirements Country Category Supply Pressure (mbar) 3+ (28-30/37) 30 (28-30) Butane 3+ (28-30/37) Propane * Appliance regulator out of action continues... Table 15 Check manifold pressure. It is important that gas be supplied to the tumble dryer in accordance with the requirements on the serial plate.
Gas Requirements WARNING When converting the tumble dryer to a different gas or pressure, first verify that the supply inlet pressure is equipped with a pressure regulator (located ahead of the tumble dryer) that will maintain the gas supply at the inlet pressure specified.
1. If country/gas category designation required is not listed on 70550204 70550213 70551904 the serial plate, affix the appropriate country/gas category la- 055 Series bel supplied over the main serial plate designations. continues... 2. Verify gas supply pressure and adjust as necessary. Refer to Figure 1 .
WARNING T45 Series Check all pipe connections, internal and external, 70747403 055 Series for gas leaks using a non-corrosive leak detection fluid. To reduce the risk of explosion or fire, DO continues... NOT USE AN OPEN FLAME TO CHECK FOR GAS CE GASES refer to Installing CE Gas Tumble Dryer section.
Gas Requirements Low Pressure Gas Pipe Sizes NOTE: Sizing calculations based on National Fuel Gas Code. Gas Pipe Size Required for 1000 BTU Natural Gas (Standard Conditions) at Upstream Pressure— 7.0 ± 1.5 inch- es water column pressure [17.4 ± 4.0 mbar, 1.74 ± 0.37 kPa] Gas Appli- Equivalent Length ances Total...
Page 61
Gas Requirements Gas Pipe Size Required for 1000 BTU Natural Gas (Standard Conditions) at Upstream Pressure— 7.0 ± 1.5 inch- es water column pressure [17.4 ± 4.0 mbar, 1.74 ± 0.37 kPa] Gas Appli- Equivalent Length ances Total BTU/hr. 25 feet [7.6 50 feet [15.2 75 feet [22.9 100 feet [30...
Gas Requirements High Pressure Gas Pipe Sizes NOTE: Sizing calculations based on National Fuel IMPORTANT: A high pressure regulator is required at Gas Code. each machine. Gas Pipe Size Required for 1000 BTU Natural Gas (Standard Conditions) at Upstream Pressure — 2.0 ± 0.4 PSI [138 ±...
Page 63
Gas Requirements Gas Pipe Size Required for 1000 BTU Natural Gas (Standard Conditions) at Upstream Pressure — 2.0 ± 0.4 PSI [138 ± 28 mbar, 13.7 ± 2.7 kPa] Gas Appli- Equivalent Length ances Total BTU/hr. 25 feet [7.6 50 feet [15.2 75 feet [22.9 100 feet [30 125 feet [38...
Gas Requirements High Altitude Burner Orifice Sizing For proper operation at altitudes above 2,000 feet [610 m] , the gas burner orifice size must be reduced to ensure complete combus- tion. Heat input derate of 4% per 1,000 feet [305 meters] of altitude above sea level. Refer to Table 18 or Table 19 . For IEC models, consult local gas supplier.
Page 65
Gas Requirements Model Market Altitude Burner Orifice feet [meters] inches Quantity Part No. [mm] L.P. Gas 2,001-4,000 0.0820 70684109 [610-1,220] [2.08] 4,001-6,000 0.0810 70694108 [1,221-1,830] [2.06] 6,001-8,000 0.0760 70684106 [1,831-2,440] [1.93] 8,001-10,000 0.0730 70684105 [2,441-3,050] [1.85] Standard T, A, J, K, Natural Gas 2,001-4,000 0.1520...
Page 66
Gas Requirements Model Market Altitude Burner Orifice feet [meters] inches Quantity Part No. [mm] 6,001-8,000 0.0760 70684106 [1,831-2,440] [1.93] 8,001-10,000 0.0730 70684105 [2,441-3,050] [1.85] ProCapture Natural Gas 2,001-4,000 0.1440 70684135 S30 Series [610-1,220] [3.66] 4,001-6,000 3.50 mm 0.1378 70684133 [1,221-1,830] [3.50] 6,001-8,000 3.40 mm...
Page 67
Gas Requirements Model Market Altitude Burner Orifice feet [meters] inches Quantity Part No. [mm] L.P. Gas 2,001-4,000 0.0820 70684109 [610-1,220] [2.08] 4,001-6,000 0.0785 70684107 [1,221-1,830] [1.99] 6,001-8,000 0.0760 70684106 [1,831-2,440] [1.93] 8,001-10,000 0.0730 70684105 [2,441-3,050] [1.85] L.P. Gas 2,001-4,000 0.0820 70684109 [610-1,220] [2.08]...
Page 68
Gas Requirements Model Market Altitude Burner Orifice feet [meters] inches Quantity Part No. [mm] 6,001-8,000 0.1610 70684142 [1,831-2,440] [4.09] 8,001-10,000 0.1510 70684139 [2,441-3,050] [3.91] T, G, A, H, L.P. Gas 2,001-4,000 0.1065 70684120 L, K [610-1,220] [2.71] 4,001-6,000 0.1015 70684118 [1,221-1,830] [2.58] 6,001-8,000...
Page 69
Gas Requirements Model Market Altitude Burner Orifice feet [meters] inches Quantity Part No. [mm] T45 Series T, G, A, H, Natural Gas 2,001-4,000 0.1730 70684146 J, K, U [610-1,220] [4.39] 4,001-6,000 0.1695 70684144 [1,221-1,830] [4.31] 6,001-8,000 0.1610 70684142 [1,831-2,440] [4.09] 8,001-10,000 0.1510 70684139...
Page 70
4,001-6,000 2.3 mm 0.0906 70684113 [1,221-1,830] [2.30] 6,001-8,000 0.0890 70684112 [1,831-2,440] [2.26] 8,001-10,000 0.0860 70684110 [2,441-3,050] [2.18] 055 Series T, G, A, H, Natural Gas 2,001-4,000 0.1850 70684150 J, K, U [610-1,220] [4.70] 4,001-6,000 0.1800 70684148 [1,221-1,830] [4.57] 6,001-8,000 0.1730...
Page 71
Gas Requirements Model Market Altitude Burner Orifice feet [meters] inches Quantity Part No. [mm] L.P. Gas 2,001-4,000 0.0860 70684110 [610-1,220] [2.18] 4,001-6,000 0.0820 70684109 [1,221-1,830] [2.08] 6,001-8,000 0.0810 70684108 [1,831-2,440] [2.06] 8,001-10,000 0.0760 70684106 [2,441-3,050] [1.93] L.P. Gas 2,001-4,000 0.1015 70684118 [610-1,220] [2.58]...
Electrical Requirements Electrical Requirements Electrical Requirements IMPORTANT: Electrical connections must be made by a qualified electrician using data on serial plate, in- stallation manuals and wiring diagram provided with WARNING tumble dryer and according to local codes. Install a circuit breaker as close to the tumble dryer as possi- ble.
Electrical Requirements • Connecting the Neutral from the electrical service box to the Wire Colors Description tumble dryer ground screw does not constitute a ground. Start Pulse Signal Input • A dedicated ground conduit (wire) must be connected be- tween the electrical service box ground bar and machine Black Start Pulse Signal Input ground screw.
Electrical Requirements Model Heat Source Ground and Terminal Block Locations Electric, low voltage Electric, high voltage TMB2736N_SVG 1. Ground 2. Power Distribution Block Gas/Steam/Electric, low voltage T45 (gas only) Gas/Steam/Electric, high voltage L1 L2 L3 TMB2738N_SVG NOTE: Connection only required in upper junction box.
Electrical Requirements Electrical Connections for T30 and T45 CAUTION Only Use copper conductors only with the following All gas tumble dryers require a single service connection to rating when wiring appliance to electric supply: TB1 of the upper unit junction box only. The serial plate re- Dryer gas and steam heat models require 187°F flects current draw, breaker rating and conductor size recom- (75°C) minimum.
Page 77
50-60 L1, Neutral, 14 [2.5] and ground 200-240 50-60 Refer to Fig- 14 [2.5] ure 22 continues... Table 22 055 Series Gas and Steam Models Voltage Code Voltage Cycle Phase Wire Full Load Recommend- Wire Size Amps ed Circuit AWG [mm...
Page 78
Electrical Requirements 380-415 50-60 L1, L2, L3 14 [2.5] and ground continues... Table 23 T30 Series Gas Models (Total Machine) Voltage Code Voltage Cycle Phase Wire Full Load Recommend- Wire Size Amps ed Circuit AWG [mm Breaker Rat- ing Amps 100-120 50-60 L1, Neutral,...
Page 79
Electrical Requirements 440-480 50-60 L1, L2, L3 14 [2.5] and ground 380-415 50-60 L1, L2, L3 14 [2.5] and ground continues... Table 26 21 kW Standard Line 030 Series Electric Models Voltage Code Voltage Cycle Phase Wire Full Load Recommend- Wire Size Amps ed Circuit...
Page 80
Electrical Requirements 12 kW Eco Line 030 Series Electric Models Voltage Code Voltage Cycle Phase Wire Full Load Recommend- Wire Size Amps ed Circuit AWG [mm Breaker Rat- ing Amps 200-208 50-60 Refer to Fig- 4 [25] ure 1 Refer to Fig- 230-240 50-60 4 [25]...
Page 81
Electrical Requirements 400-415 50-60 L1, L2, L3 8 [10] and ground 50-60 L1, L2, L3 8 [10] and ground 460-480 50-60 L1, L2, L3 8 [10] and ground continues... Table 30 12 kW Eco Line T30 Series Electric Models (Per Pocket) Voltage Code Voltage Cycle...
Page 82
Electrical Requirements 200-208 50-60 L1, L2, L3 3 [26.7] and ground 230-240 50-60 L1, L2, L3 4 [25] and ground 50-60 L1, L2, L3 8 [10] and ground 400-415 50-60 L1, L2, L3 8 [10] and ground 50-60 L1, L2, L3 8 [10] and ground 460-480...
Page 83
Electrical Requirements 460-480 50-60 L1, L2, L3 12 [4] and ground continues... Table 33 18 kW Medium 035 Series Electric Models Voltage Code Voltage Cycle Phase Wire Full Load Recommend- Wire Size Amps ed Circuit AWG [mm Breaker Rat- ing Amps Refer to Fig- 200-208 50-60...
Page 84
Electrical Requirements 27 kW Standard Line 055 Series Electric Models Voltage Code Voltage Cycle Phase Wire Full Load Recommend- Wire Size Amps ed Circuit AWG [mm Breaker Rat- ing Amps 200-208 50-60 Refer to Fig- 2/0 [70] ure 22 Refer to Fig-...
Page 85
Electrical Requirements 230-240 50-60 L1, L2, L3 6 [16] and ground 50-60 L1, L2, L3 8 [10] and ground 400-415 50-60 L1, L2, L3 8 [10] and ground 50-60 L1, L2, L3 8 [10] and ground 460-480 50-60 L1, L2, L3 10 [6] and ground continues...
Steam Requirements Steam Requirements Steam Requirements pass trap to drain condensate from the low point in the steam header to the return. • In both steam supply and steam return line, it is recommend- WARNING ed that each have a pipe union and shut-off valve. This will enable you to disconnect the steam connections and service This appliance does not contain inherent pressure the tumble dryer while your laundry facility is in operation.
Page 87
Steam Requirements TMB2646N_SVG NOTE: Refer to Table 38 for sizing of steam lines. Piping must also be sized accordingly for length of runs and number of elbows. 1. Steam Coil 2. 12 in. [300 mm] Riser 3. Condensate Return Line from Supply Line 4.
Adjustments Adjustments Adjustments CAUTION To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumble dryer before servicing. • Close gas shut-off valve to gas tumble dryer be- fore servicing. • Close steam valve to steam tumble dryer before servicing.
Adjustments WARNING The tumble dryer must not be operated if the airflow switch does not operate properly. Faulty airflow switch operation may cause an explosive gas mixture to collect in the tumble dryer. W072R1 IMPORTANT: Airflow switch vane must remain closed during operation.
Adjustments 2. Retighten acorn nut. TMB2105N_SVG1 TMB997N_SVG 1. Switch Actuator 1. Door Strike Screw 2. Acorn Nut Figure 26 Figure 27 Door Strike The door strike must be adjusted to have sufficient tension to Manual Resettable Thermostat hold loading door closed against force of the load tumbling against it.
Before You Call for Service Before You Call for Service Won’t Start Won’t Heat Clothes Not Dry Possible Reason – Corrective Actions • Insert correct coin(s) or valid card if applicable. • Close the loading door tightly. • Close lint panel tightly. •...
Removing Tumble Dryer from Service Removing Tumble Dryer from Service If the tumble dryer is to be removed from service, perform the 1. Turn off electrical supply external to machine. following steps where applicable: 2. Turn off gas supply external to machine. 3.
Disposal of Unit Disposal of Unit This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Refer to Figure 28 .