Downstream Centrifugal Fan Heater Assembly, Operations, and Parts Manual INSTALLATION AND WIRING MUST BE IN ACCORDANCE WITH CEC, NEC, AND LOCAL ELECTRICAL Original Instructions CODES Read this manual before using product. Failure to Part Number: 040729 R01 follow instructions and safety precautions can Revised: 2017-12-27 restult in serious injury, death, or property 018979 R01...
Since 1959, NECO equipment has been proudly designed, manufactured, and supported for customers here in the USA and around the world. With proper operation and maintenance, the equipment will provide years of safe and dependable service. NECO is continually testing and improving our products in order to provide you with the safest, most effi cient, and most economical grain handling &...
• Buyer further agrees that in no event shall NECO have liability for loss of use, loss of profi ts, or for any indirect, incidental, or consequential damages on any claim of any kind.
SAFETY OPERATOR QUALIFICATIONS • Anyone who has not read or does not completely understand all operating and safety instructions contained within this manual is not qualified to operate the equipment. READ • Only competent and experienced persons should operate farm equipment. Anyone operating or UNDERSTAND working around power equipment must under- stand and meet all legal and contractual require-...
BIN SAFETY EQUIPMENT INSPECTION • Never enter a bin without being monitored • SHUT OFF, LOCK OUT, & TAG OUT all by another person. power sources to the equipment prior to any inspection, adjustment, service, or maintenance. • Do not enter the grain bin unless all pow- •...
PRODUCED BY THE IGNITION UNIT. AVOID FIRE, EXPLOSION, AND ASPHYXIATION HAZARDS NECO Heaters are designed for drying crop output in grain bins. They provide heated air via grain bin plenums (found underneath full-floor bins) or via in-floor ductwork. Consult the NECO factory before attempting to use heaters for EZEE-DRY applications.
3’ from the side of the transition (below the drying floor). Attach the probe bracket over the hole with screws (see Figure 2). Though not strictly necessary, NECO highly recommends using a burner control device with a modulat- ing valve heater. When a burner control device is not used, jump the two terminals on the terminal strip in the heater control box normally used for the control device.
Page 9
Heater Unloading System BURNER CONTROL SINGLE HEATING UNIT (THERMOSTAT/ HUMIDISTAT) Heater 1 1/2 SHEETS MIN. FOR SECOND HEATER Unload System TWO HEATING UNITS Figure 1. Fan Placement Figure. 2 Modulating Valve Installation...
Page 10
Figure 3 are representative of transition sizes The unit must be securely mounted. If you available from NECO. Where non-NECO transi- choose to mount your fan and heater on a tions are used, make sure that the area of the...
NECO premium in the fan and heater. axial fans and axial heaters 24” and greater NECO does not supply or sell ground rods and are equipped with cable attachment brackets wires. Please contact your local electrical parts (located at the handles).
See Tables 1 and 2. NOTE: To reduce the likelihood of vaporizer frosting, NECO highly recommends placing a The inside of the supply tank must be free of regulator (minimum 60 PSIG) at the tank. Make dirt and other contaminants.
5 to 15 psi [34 to 103 kPa] under flow. NOTE: NECO does not sup- ply regulators. The regulator should be located at or near the dryer to reduce the length of the supply line.
The tank should be equipped with a vapor and ing more heaters or if the ambient temperature liquid tap. NECO recommends that each day’s is low. The vaporization rate of propane con- initial heater startup should be performed using stantly changes according to ambient tempera- the vapor tap.
COMPONENT tween the regulator and the burner. It is opened during the ignition sequence. IDENTIFICATION and FUNCTION On natural gas models this valve controls the flow of gas between the regulator (supplied by for Heaters Equipped the customer) and the burner. It is also opened with Fenwal Boards during the ignition sequence.
Page 18
Air Switch (if equipped, PN F148003) Relief Valve (LP models only) (PN F048424) The Air Switch is a safety device that proves Relief valves prevent excessive pressure build- up in the fuel line. whether or not there’s airflow from the fan. Honeywell Spark Generator (PN 040365) Push Button Start/Stop Switch (PN F048401) Regulator (LP models only) The Spark Generator is used to provide the ac- (BY REGO - PN F048404)
The regulator setting determines the amount of button. heat generated by the burner. NECO provides a regulator for liquid propane heaters. Natural gas suppliers should provide a regulator for natural gas heaters. The burner control, whether ther- mostat, humidistat, or modulating valve, deter- mines the temperature under the bin.
INITIAL STARTUP USING PROPANE HEATER OPERATIONS NECO liquid propane heaters require pro- pane vapor for start-up. NECO recommends that the supply tank be fitted with both a va- 04DSH1LPH 04DSH1NGH por tap and a liquid tap. Short lines coming 04DSH2LPH 04DSH2NGH out of each tap can meet at a “T” joint that feeds into the heater through a third line.
quently enough then the gas pressure is too HEATER OPERATIONS FOR high and should be reduced gradually. HI-LO MODELS 11. After adjustments are made to the regula- tor, the ball valve may need to be reposi- 04DSH1LPHL 04DSH1NGHL tioned so that a frequency of 50% high and 04DSH2LPHL 04DSH2NGHL 50% low fire is achieved.
HEATER OPERATIONS FOR MODULAR VALVE MODELS 04DSH1LPM 04DSH1NGM ______________________________________ 04DSH2LPM 04DSH2NGM 04DSH3LPM 04DSH3NGM * If the burner fails to ignite after 4 seconds, the unit will wait another 15 seconds before making Before starting the heater make sure the tem- a second attempt to ignite.
Page 23
RECOMMENDED DRYING TEMPERATURES Determine the following: Do not automatically set the plenum tempera- •the type of crop you'll be drying, ture to the maximum recommended tempera- •the target drying temperature ture. Grain quality is enhanced when drying is •the type of drying system to be used accomplished at lower temperatures.
7. Make sure fuel tanks are cool. Cool them if different companies. NECO heaters are necessary. designed to be used with NECO fans only. Safety features built into one company's REMOVE ALL GRAIN units may not be properly triggered when...
INSTALLATION AND OPERATION INSTRUCTIONS SERIES V50 FORM 996-61-4 JOHNSON CONTROLS SERIES V50 JOHNSON CONTROLS, INC. CONTROL PRODUCTS DIVISION SELF-OPERATED MODULATING VALVES 1302 EAST MONROE STREET GOSHEN, IN 46526 For Outdoor Crop Dryer Service APPLICATION As in many instances the outside tem- perature will not be high enough to provide a regulating valve with pres- These valves control the flow of...
Page 27
ORIFICE SIZES IN KIT NO. PLG14A-600R Replace this plug with Orifice Plug when ORIFICE SIZE COLOR bypass is required CODE .040 1.02 .062 1.57 Yellow .078 1.98 Green .093 2.36 Blue .125 3.18 Aluminum SOLID PLUG Brass Orifice plug - See Table for orifice sizes in PLG14A-600R Kit Figure 13 - Internal bypass within Figure 14 - Typical piping for the...
TROUBLESHOOTING OF THE FENWAL IGNITION MODULE Input Polarity 7. Check the connections on the Honeywell Spark Generator. If the system shuts down after the ignition trial period even though a spark is present and the Valve Malfunction gas valves are open, check that the input volt- age at terminals (L1) and (L2) is neutral.
GENERAL MAINTENANCE isconnect all power before doing maintenance. Perform the following tasks at the beginning of each drying season. _________1. Clean any debris out of the fan and heater housing. _________2. Check wiring for loose connections, bare wires, and damage caused by rodents. _________3. Check the flame probe for cracked insulation.
Replacement Parts Liquid Propane Fuel Line Replacement Parts ................45 Liquid Propane Inlet Control Loop, USA & CE Models ............45 Liquid Propane Inlet Control Loop, CSA Models ..............46 On-Off Fuel Control Loop for Liquid Propane, DSH1 & 2, USA and CE Models ....47 On-Off Fuel Control Loop for Liquid Propane, DSH3, USA and CE Models ......
Page 34
REPLACEMENT PARTS Figure 15 shows the main replacement parts for these styles and are separated with a slash the Downstream Heater. The abbreviations for mark. Electrical Components are not shown. liquid propane (LP) and natural gas (NG) carry different part numbers. The abbreviation for a All fuel loops styles are shown on the following downstream heater 3, liquid propane (DSH3LP) pages.
Hi-Lo Fuel Control Loop for Liquid Propane, DSH1 & 2, USA and CE Models On-Off Control Fuel Loop (081085) Hi-Lo Add-on Fuel Loop (040911) Replacement Parts Figure 22.
Hi-Lo Fuel Control Loop for Liquid Propane, DSH3, USA and CE Models On-Off Control Fuel Loop (N.A.) Hi-Lo Add-on Fuel Loop (040911) Replacement Parts Figure 23.
Hi-Lo Fuel Control Loop for Liquid Propane, DSH3, CSA Models On-Off Fuel Control Loop (N.A.) Hi-Lo Add-on Fuel Control Loop (081034) Replacement Parts Figure 25.
Hi-Lo Fuel Control Loop for Natural Gas, DSH1 & 2, USA and CE Models (083221) On-Off Fuel Control Loop (083184) Hi-Lo Add-on Fuel Control Loop (040911) Replacement Parts Figure 34.