How to connect dop-300 to diacloud via wired ethernet and wi-fi dongle

Advertisement

Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle
Doc. Code:152A-P-D2412-APN002-EN
Topic: How to connect DOP-300 to DIACloud via wired Ethernet and
Wi-Fi Dongle
Applicable
DOP-300S
model
DX-MWB-01N Wi-Fi dongle
Keyword
Rev.01
Page 1/23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DOP-300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta DOP-300

  • Page 1 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN Topic: How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Applicable DOP-300S model DX-MWB-01N Wi-Fi dongle Keyword Page 1/23...
  • Page 2: Table Of Contents

    Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN Table of Contents INTRODUCTION ............................3 SCENARIO ..............................3 HARDWARE/SOFTWARE CONFIGURATION ..................3 OPERATIONAL STEPS ..........................5 FUNCTION TESTING ..........................20 FUNCTION DESCRIPTION ........................22 CONCLUSION ............................
  • Page 3: Introduction

    Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 1. Introduction DIACloud is an IoT cloud platform specially designed for machine manufacturers and end customers. DIACloud allows you to easily create customized dashboards and use them to collect, analyse and utilize data to improve efficiency, help administrators obtain machine status, and monitor device status from anywhere in the world through a web browser on a PC.
  • Page 4 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN  Plan 1: DOP-300 + Ethernet Device Type Quantity DOP-3S07S3E2 Cable RJ45 Architecture: Plan 2: DOP-300 + Wi-Fi Dongle  Device Type Quantity DOP-3S07S3E2...
  • Page 5: Operational Steps

    Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 4. Operational Steps This chapter demonstrates how the HMI connects to DIACloud through wired Ethernet and wireless Ethernet Wi-Fi Dongle respectively:  Plan 1: DOP-300 with wired Ethernet 1.
  • Page 6 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 2. Check Enable cloud template: Click DIAScreen > IIoT > DIACloud > Cloud Template. Create a new template > Enter relevant information > Click OK.
  • Page 7 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 3. Click Start Transfer to upload the project and tags to the cloud. 4. Enter your account and password and click Login > The template is uploaded successfully.
  • Page 8 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 6. After completing the above steps, please connect the HMI and the network through the RJ45 network cable 7. Next, please use barcode or Bluetooth to bind the HMI to DIACloud.
  • Page 9 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN c. Install eDIACloud App on iPhone/ Android phone. IOS Download link: https://testflight.apple.com/join/2pkeme9g d. Open eDIAcloud and log in. If you have not registered an account yet, please click Register Now to register.
  • Page 10 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN f. Enter the following relevant information and click OK.  Bind HMI to DIACloud via Bluetooth Page 10/23...
  • Page 11 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN a. Open eDIACloud and log in If you have not registered an account yet, please click Register Now to register. IOS Download link: https://testflight.apple.com/join/2pkeme9g...
  • Page 12 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN b. Click Nearby to search for nearby Bluetooth devices, and the scanning results will be displayed on the interface. c. Click the device and enter the HMI PIN code.
  • Page 13 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN d. Click Yes to bind HMI to DIACloud. So far, all settings have been completed.  Plan 2: DOP-300 with wireless Ethernet (Wi-Fi Dongle) 1.
  • Page 14 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 3. After scanning, the following screen will appear. Please enter the PIN code (please refer to the blue box in the picture above) and click Next.
  • Page 15 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 4. Follow the instructions to scan the HMI serial number. 5. After filling in the information, click OK. Completing this step means that the HMI binding process has been completed.
  • Page 16 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 6. Download the HMI project: DIAScreen > IIoT page > Cloud template > Check Enable cloud template. 7. Click New Template and fill in the relevant information and click OK.
  • Page 17 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 8. Click Start Transfer to upload the project and label settings to the cloud. 9. Enter your account number and password and click Log In.
  • Page 18 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 11. Press and hold on a blank area of the HMI screen for three seconds. The system toolbar on the left will appear and click 12.
  • Page 19 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN After clicking on the network name, you can view the network name related content and connection status. Page 19/23...
  • Page 20: Function Testing

    Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 5. Function Testing After completing the steps above, you can see the device status through the following three paths.  From the website 1. Log in to https://hms.diacloudsolutions.com/...
  • Page 21 Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN  From the mobile phone 1. Click icon to log in and click device. Note: Green light means successful connection, gray light means offline.
  • Page 22: Function Description

    Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN Status: Name Description The HMI has not yet bound an account, but can access the external Account unbound network. The HMI has not yet bound an account and cannot access the external Offline network.
  • Page 23: Conclusion

    Rev.01 Doc. Name:How to connect DOP-300 to DIACloud via wired Ethernet and Wi-Fi Dongle Doc. Code:152A-P-D2412-APN002-EN 7. Conclusion This chapter demonstrates how the HMI connects to DIACloud via wired Ethernet and wireless Ethernet (Wi- Fi Dongle). Page 23/23...