FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed
where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions
in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices
and instructions may result in property damage, personal injury, or death. Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which may cause serious injury, property damage, or death.
ATTENTION INSTALLER – This manual contains important information about the installation, operation and safe use of this product. This information should be given
Page 1
Manuel d’installation et d’utilisation Manual de instalación y operación DiveAway Jump System WARNING FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist.
ENGLISH S.R.Smith DiveAway Jump System | Installation & Operation Manual ® Table of Contents Section 1. Important Safety Instructions ..3 Section 4. Article 5 - Pool Dimensions and Tolerances Extracted from the ANSI/APSP/ICC-5 2011 Section 2. Placement ......... 4...
S.R.Smith DiveAway Jump System | Installation & Operation Manual ENGLISH ® Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS WARNING PROFESSIONAL INSTALLATION RECOMMENDED Improper installation voids S.R. Smith’s Limited Product Warranty. POOL WATER ENVELOPE DIMENSIONS MUST MEET OR EXCEED ANSI/APSP/ICC-5 2011 STANDARDS FOR THIS STAND. USE ONLY WITH A COMPATIBLE S.R.
ENGLISH S.R.Smith DiveAway Jump System | Installation & Operation Manual ® Section 2. Placement Concrete Slab Water Surface Figure A. IMPORTANT NOTICE S.R. SMITH cannot guarantee customer’s concrete strength or thickness. L (ft.) W (ft.) T (in.) Reinforcing 8.00 4.00 #4'S @ 18"...
17.0" 24" 26" Table B. DiveAway Installation Chart - Refer to Figure A. NOTE: *WA dimension is valid only in conjunction with Follow these guidelines to make sure that the min. depth at Point A (See Section 4, ANSI Pool anchor jig is installed properly: Dimensions and Tolerances, page B) for pool type.
ENGLISH S.R.Smith DiveAway Jump System | Installation & Operation Manual ® 2.50 Figure C. Item No. Part Number Description Included In Kit # 4-554 NEW CONSTRUCTION ANCHOR JIG 69-209-013 800-0132 HEX NUT, 1"-8 GALVANIZED STEEL 69-209-013 300-6700 FLUSH DECK ANCHOR...
Page 7
S.R.Smith DiveAway Jump System | Installation & Operation Manual ENGLISH ® Existing slab shall exhibit no signs of cracking through the tubes in the Anchor Jig and or deterioration. thread the bolts into the anchors until the top surface of the anchors contact the bottom of S.R.
Anchor screws are flush with the top of the anchors. The wheels on the back of the DiveAway can be used to roll the DiveAway to the storage location by lifting the front edge of the board upward until the wheels contact the deck.
Page 9
S.R.Smith DiveAway Jump System | Installation & Operation Manual ENGLISH ® Minimum Cross Sections (Refer to Section 4, ANSI Pool Dimensions and Tolerances, Figure 3 on Page B) Water Level Water Level Water Level Water Level C L Symbol C L Symbol...
ENGLISH S.R.Smith DiveAway Jump System | Installation & Operation Manual ® Section 4. Article 5 - Pool Dimensions and Tolerances Extracted from ARTICLE 5 – POOL DIMENSIONS AND TOLERANCES the ANSI/APSP/ICC-5 2011 American National Standard for EXTRACTED FROM THE ANSI/APSP/ICC-5 2011...
Page 11
S.R.Smith DiveAway Jump System | Installation & Operation Manual ENGLISH ® Page 11...
Page 12
ENGLISH S.R.Smith DiveAway Jump System | Installation & Operation Manual ® 5.4 Offset Ledges 5.4.1 Offset ledges shall be a maximum of 8 in. (203 mm) wide. 5.4.1.1 Offset ledges located less than 42 in. (1.07 m) below waterline shall be proportionately less than 8 in. (203 mm) wide and fall within 11°...
Page 13
S.R.Smith DiveAway Jump System | Installation & Operation Manual ENGLISH ® wall. The center of the tip of the diving board, platforms, manufactured or field fabricated shall be located directly above Point A. 5.8.1.3 Point A as shown in Figure 3 and Table...
Page 14
ENGLISH S.R.Smith DiveAway Jump System | Installation & Operation Manual ® Appendix F Recommendations to Warn Against Shallow Water Diving This appendix is not part of the American National Standard ANSI/APSP/ICC-5 2011. It is included for information only. Recommended methods to warn against shallow water diving may include, but not be limited to: A.
• Do not allow roughhousing and horseplay. • Keep deck clean and clear of objects that may create a hazard. S.R.Smith DiveAway Jump System | Installation & Operation Manual ENGLISH ® • Keep all breakable objects out of the pool area.
Need help?
Do you have a question about the DiveAway and is the answer not in the manual?
Questions and answers