CLEANING MODE ----------------------------------------------------------------------------------------16 6.1.1 MANUAL NOZZLE CLEAN -------------------------------------------------------------------------------16 REMOTE CONTROL CLEANING -------------------------------------------------------------------------16 REMOTE CONTROL BATTERY ---------------------------------------------------------------------------16 CLEANING BETWEEN THE PORCELAIN AND THE CLEANET SIT SURFACE -------------------------16 FILTER CLEANING ----------------------------------------------------------------------------------------17 DESCALING PROCESS ----------------------------------------------------------------------------------17 TROUBLESHOOTING ------------------------------------------------------------------------------------ 18 TECHNICAL DATA CLEANET SIT ---------------------------------------------------------------------- 20...
Do not bend or squeeze the connecting tube or the power cable; and keep the cable away from humid, hot or sharp surfaces. Do not install the product in wheeled vehicles or boats. Ignoring these precautions may cause fire, electric shock, short-circuit or damages to the device. Visit www.laufen-cleanet.com to view the Declaration of Conformity...
Its use is restricted to enclosed spaces. Any other use will not be deemed in accordance with its purpose and Laufen will not accept any responsibility for the consequences that might arise from an improper use.
30 seconds from the moment the CLEANET SIT detects the user until any water function is activated. When a function is activated, the CLEANET SIT carries out a cleaning of the nozzle before its use.
2 INTRODUCTION REMOTE CONTROL LINKING If needed, a remote control link process can be carried out. Please power on the product, wait 15 seconds until the power on is complete, and then both press rear shower and rotary button for consecutive 3 seconds at less than 10cm of the product. Please complete the setup within 60 seconds, when the self-test process ends, 2 “beeps”...
SHOWER TOILET Remote control Controller with rotary button CONTROLLER WITH ROTARY BUTTON You can operate the Laufen shower toilet easily by turning and pressing the controller located on the right. The following functions can be activated using the controller: •...
Shower jet position adjustment Air speed adjustment Default settings LAUFEN APP, Smart Control Your shower toilet can be operated easily with LAUFEN Smart LAUFEN APP Control for iPhone and Android, including useful special functions. For further descriptions, see section 4.
4 OPERATING THE SHOWER TOILET Your Laufen shower toilet can be operated using either the controller with remote or the Laufen APP. Laufen Gegenüberstellung Icons Menu Rear shower 25 sec POWER Lady shower alternativer Iconvors chlag, da S ymbol bei iOS bereits für den...
4 OPERATING THE SHOWER TOILET Water / dryer temperature User profile Seat temperature Stop REAR SHOWER Press rear shower button to activate function, If you need to stop the shower prematurely, press the rotary button to stop. This time can be configured through the Smart Control APP. LADY SHOWER Press lady shower button to activate function, If you need to stop the shower prematurely, press the rotary button to stop.
4 OPERATING THE SHOWER TOILET SHOWER JET INTENSITY 4.1.1 The jet intensity can be adjusted to one of 5 settings. You can adjust the jet intensity while showering by turning the controller. Turn the controller rightwards to increase the jet intensity. Turn the controller leftwards to decrease the jet intensity.
4 OPERATING THE SHOWER TOILET WATER TEMPERATURE ADJUSTMENT 4.1.5 While showering, after this temperature button press, turn the rotary control button to increase or decrease the water temperature. The temperature of the temperature can be adjusted to one of 5 settings. Turn the controller rightwards to increase water temperature.
4 OPERATING THE SHOWER TOILET HEATED SEAT The temperature of the seat can be adjusted to one of 5 settings. Press seat heater button to activate, turn rotary button to right (to increase) or leftwards (to decrease) to adjustment temperature. It will take a few minutes to heat the seat.
4 OPERATING THE SHOWER TOILET SILENT MODE Press seat heater button for consecutive 3 sec to silent mode ON or OFF. Silent mode ON: LED display green light and double acoustic signal. Silent mode OFF: LED display blue light and long acoustic signal. DEFAULT SETTINGS Reset function will recover the default factory settings to the product.
Laufen Connect APP. ×2 The drying function can be configured to activate automatically after the washing time through the Laufen Connect APP DRY AIR SPEED 5.2.1 While dryer function is used, turn the rotary control button forwards to increase the air speed, turn the rotary control button back to decrease the air speed.
Please use AAA Alkaline battery. Do not mix the new and used batteries nor different brands. CLEANING BETWEEN THE PORCELAIN AND THE CLEANET SIT SURFACE The product is fixed by a clip and some magnets. It can be disassembly from the magnet fixation if you pull up the device, but keeping the clip bracket fixation.
1 long beep signal to indicate the process is end. 15 min ×1 3 sec 3 sec ORDER DESCALING AGENT H8946970000001 During this process, no function should work For descaling only use the Laufen descaling agent (H8946970000001). It may caused damage if it is used another descaling agent.
Risk of death! Contact Laufen customer services. MESSAGES AND FAULTS Laufen customer services If faults occur and cannot be rectified using the information in the operating manual, Please contact Laufen customer services. www.laufen-cleanet.com PROBLEM POSSIBLE CAUSE SOLUTION Adjust water pressure using the remote (rear Water pressure is low shower and lady shower see 4.1.1 ) or with...
Page 19
TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The lights blink 7 times every 5 seconds. Error (E7) on APP. Water temperature sensor is damage. * The water temperature sensor error. The air temperature setting is off. Or Check dryer temperature adjustment (see 4.2) The lights blink 8 times every 5 badly adjusted or reset heated dryer temperature.
9 DISPOSAL AND ENVIRONMENT The Laufen shower toilet complies with the requirements of EU Directive “Restriction of Hazardous Substances” (2002 / 95 / EC). It is largely free of hazardous substances such as lead, cadmium, mercury, and chromium VI. Correct disposal of old appliances Waste electrical equipment often contains materials that are still usable.
Need help?
Do you have a question about the CLEANET SIT and is the answer not in the manual?
Questions and answers