Table 1-6. LCD Status Messages (continued)
Code
Text
E1211 ROMB Batt
E1214 ## PwrGd
E1215 ## PwrGd
E1226 PCI Rsr 1.5V
PwrGd
E1229 CPU # VCORE
E122A CPU VTT PwrGd Processor # VTT voltage has
E1310 RPM Fan ##
E1311 FAN MOD ##
RPM
E1313 Fan
Redundancy
24
About Your System
Causes
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Specified voltage regulator
has failed.
Specified voltage regulator
has failed.
1.5V Riser Card Power Good
failure.
Processor # VCORE voltage
regulator has failed.
exceeded the allowable
voltage range
RPM of specified cooling
fan is out of acceptable
operating range.
RPM of specified cooling
fan module is out of
acceptable operating range.
The system is no longer fan-
redundant. Another fan
failure will put the system at
risk of over-heating.
Corrective Actions
Reseat the RAID battery
connector. See
"Troubleshooting a SAS or
SAS RAID Controller" on
page 147, and
"Troubleshooting System
Cooling Problems" on
page 136.
See "Getting Help" on
page 167.
See "Getting Help" on
page 167.
See "Getting Help" on
page 167.
See "Getting Help" on
page 167.
See "Getting Help" on
page 167.
See "Troubleshooting
System Cooling
Problems" on page 136.
See "Troubleshooting
System Cooling
Problems" on page 136.
Check control panel LCD
for additional scrolling
messages. See
"Troubleshooting System
Cooling Problems" on
page 136.