Parameters setting :
Parameters would be set according to the following circular mode for the first time. All the parameters
are set and saved instantly. First of all, make sure the power is on.
-
Choose HEAT/COOL mode:
RT: real-time temperature;
Press SET key for 3sec to enter HEAT/COOL mode menu and M flashing:
HEAT: Heating output, COOL: Refrigeration. Press the UP or DOWN key to choose mode, and the
corresponding mode icon will light.
-
Daytime temperature setting:
Press SET key for 3 seconds to display the default temperature value while icon SET and icon Day time is
flashing,then press the UP or DOWN key to select the ideal temperature you want.
-
Nighttime temperature setting:
Press SET key once to display the default temperature value while icon SET and iconNight time flashing, then
press the UP or DOWN key to select the ideal temperature you want.
-
Temperature difference
Press SET key until DL icon flashing and display current value, press UP or DOWN key to select the ideal
temperature difference you want.
-
Over temperature alarm setting:
Press SET key once until the lower part of icon Alarm status flashing and displaying the current over
temperature alarm value, press UP or DOWN key to select the idea over temperature you want.
-
Timing setting:
Notice that while start time and end time is same, this timing control become invalid
First timing control L1:
Start time setting: Press SET key until display L1 and FROM icon flashing, at the same time display the default
time, press UP or DOWN key to set the hour;
After hour set, press SET key to set the minute, press UP or DOWN key to set the value;
End time setting: When start time is already finished, press SET key and then TO icon flashing, you can set end
time in the same method.Second timing control L2: The same operation with first timing control L1.
-
Real-time setting:
Press SET key, icon clock flashing and display current hour set value, press UP or DOWN key to adjust the
system time; Press the SET key and then set the minute value in the same method.
-
Daytime time setting:
Start time setting: Press SET key, Daytime and clock icon flashing, at the same time FROM flashing and display
default hour value, press UP or DOWN key to modify the value. After the hour set, press SET key to set the
minute, press UP or DOWN key to set the value; End time setting: When start time is already finished, press
SET key and then TO icon flashing, you can set end time with the same method of start time setting.
-
Night time time setting:
Start time setting: Press SET key, Nighttime and clock icon flashing, at the same time FROM flashing and
display default hour value, press UP or DOWN key to modify the value.
After hour set, press SET key to set the minute, press UP or DOWN key to set the value;
End time setting: When start time is already finished, press SET key and then TO icon flashing, you can set end
time with the same method of start time setting.
Tips:
If the current menu doesn't need adjustment, press SET key directly to switch to the next menu, press SET key
for 3 seconds to exit and save settings.
Parameters of temperature and timer can be recycled by pressing the UP or DOWN key in normal status.
The product returns to normal working condition automatically without any key operating in 15 seconds.
Parameter adjustment : Press UP or DOWN key and hold, enter into quickly adjusting state.
Set high and low limits of the set temperature:
In normal working status:
High limit: Press UP key for 5 seconds to display current high temperature limit setting(50℃), and then press
UP or DOWN key to modify the set value.
Low limit: Press DOWN key for 5 seconds to display original low temperature limit setting(0℃), and then press