Service Checklist - A.O. Smith FPS 75 Technical Information

A.o. smith power vent water heaters specification sheet
Table of Contents

Advertisement

FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK
SERVICE CHECKLIST
VI
PROPER SEQUENCE OF OPERATION
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
no
no
A. FPS40 - 50
During standby is blower off?
On a call for heat does gas valve open?
Does gas pressure switch close?
Does the blower come on?
If so, does the air pressure make?
Does the solenoid open?
Does main burner ignite?
Does the thermostat satisfy?
Comments:
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
no
no
A.FPSE40-50
During standby is blower off?
On a call for heat does gas valve open?
Does gas pressure switch close?
Does the blower come on?
If so, does the air pressure make?
Does the solenoid open?
Does main burner ignite?
Does the thermostat satisfy?
Comments:
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
no
no
A. FPD40 - 50
During standby is blower off?
On a call for heat does gas valve open?
Does gas pressure switch close?
Does the blower come on?
If so, does the air pressure make?
Does the solenoid open?
Does main burner ignite?
Does the thermostat satisfy?
Comments:
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
no
no
A. FPS75
During standby is blower off?
On a call for heat does gas valve open?
Does gas pressure switch close?
Does the blower come on?
If so, does the air pressure make?
Does the solenoid open?
Does main burner ignite?
Does the thermostat satisfy?
Comments
@1995
A.D.
Smith
Water Products Co
Technical Information
Irving, Texas
97

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fps40Fps50Fpse50

Table of Contents