Advertisement

Quick Links

Operating Instructions
F
Version 3.0
HYDROMETTE
BL COMPACT
RH-T flex 350
EN
[Geben Sie Text ein]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYDROMETTE BL COMPACT RH-T flex 350 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GANN HYDROMETTE BL COMPACT RH-T flex 350

  • Page 1 Operating Instructions Version 3.0 HYDROMETTE BL COMPACT RH-T flex 350 [Geben Sie Text ein]...
  • Page 2 Disclaimer GANN Mess- u. Regeltechnik GmbH does not make any assurances or warranties with respect to this document and, to the extent permitted by law, limits its liability for breach of any implied warranty to the replacement of this document with another. Furthermore, GANN Mess- u. Regeltechnik GmbH reserves the right to revise this publication at any time without having to notify anyone about such revisions.
  • Page 3: Table Of Contents

    Table of Contents Foreword ............................5 User Description ........................5 Intended Use ........................... 5 Non-Intended Use ........................5 Explanation of the General Warnings ..................6 General Safety Instructions ..................... 7 1.5.1 Persons at Risk ........................7 1.5.2 Preparation and Start-up ......................8 1.5.3 Use / Operation ........................
  • Page 4 Battery Monitoring ........................ 25 Querying the Device Firmware ....................25 Installation of the PC-Software GANN Dialog Pro ................. 26 USB-Communication with a PC ..................... 28 Application Notes .......................... 29 General Notes on Humidity / Air Temperature Measurement ..........29 Using the Hydromette BL Compact RH-T ................30 9.2.1...
  • Page 5: Foreword

    1 Foreword 1.1 User Description These instructions are intended for the end user of the product. The end user of the product is a person who has read and understood these operating instructions, is an experienced user of similar devices and is aware of all possible dangers and can act accordingly. The device may only be used by persons aged 14 and over who have read and understood these operating instructions, are familiar with the operation of similar products and are aware of all possible dangers and act accordingly.
  • Page 6: Explanation Of The General Warnings

    1.4 Explanation of the General Warnings The following danger levels are used in this operating manual to indicate potentially dangerous situations and important safety instructions: Danger Level Description Danger / Indicates a hazardous situation which, if not avoided, will result in death or serious irreversible injuries. DANGER Warning / Indicates a hazardous situation which, if not avoided, could result in death or serious irreversible injuries.
  • Page 7: General Safety Instructions

    1.5 General Safety Instructions It must be ensured that the complete instructions and all safety instructions have been read and understood before using this device. All instructions must be followed. This prevents accidents that can result in property damage or minor or moderate injuries.
  • Page 8: Preparation And Start-Up

    1.5.2 Preparation and Start-up Never store or place the device in a location where it can fall or be drawn into water or other liquids. To avoid the risk of electric shock, never immerse the device in water or other liquids. Always remove all packaging before operating the device.
  • Page 9: Care, Maintenance And Inspection

    Caution, there is a risk of explosion if the wrong type of battery is inserted. Handle used batteries according to the manufacturer's instructions. Gann Mess- u. Regeltechnik GmbH accepts no liability for damage caused by non-compliance with the operating instructions or by violation of a duty to care during transport, storage or operation of the instrument, even if this duty to care is not specifically discussed in the operating instructions.
  • Page 10: Specifications

    2 Specifications 2.1 Technical Data Hydromette Display: LCD segment display with three lines Display resolution: 0.1 % for humidity 0.1 °C for temperature Response time: < 2 s Storage conditions: + 5 to + 40 °C - 10 to + 60 °C (for a short time) Operating conditions: 0 to + 50 °C - 10 to + 60 °C (for a short time)
  • Page 11: Transport- & Storage Conditions

    2.3 Transport- & Storage Conditions The Hydromette BL Compact RH-T may only be stored in the packaging provided by the manufacturer or available from the manufacturer as an accessory. The manufacturer shall not accept any liability or warranty for damage that may occur to the device or to the sensor system as a result of non-compliance.
  • Page 12: General Information

    Operational reliability and functionality are no longer ensured if the device is modified or adapted. Gann Mess- u. Regeltechnik GmbH shall not be liable for any damage arising from such modifications or adaptations. The risk is borne solely by the user.
  • Page 13: Description Of The Product

    (EMC) or absolute humidity (in g/m³) can be displayed. The silicone buttons give haptic feedback for important functions. The measuring instrument has a mini-USB port that can be used to download any firmware updates using the free GANN Dialog Pro PC software. ® Version 3.0...
  • Page 14: Device Layout And Button Assignment

    5 Device Layout and Button Assignment Sensor LCD-segment display Up button On / Off button Down button Measure button ("M" button) Mini-USB port Figure 5-1: View of the Hydromette BL Compact RH-T ® Hydromette BL Compact RH-T flex 350 Version 3.0...
  • Page 15: Display Symbols

    5.1 Display Symbols 5.1.1 Main Menu Symbols Relative humidity in r.H.% "Hold" symbol Temperature in °C Display measuring mode nzeige Mess-Modus Figure 5-2: Main menu symbols 5.1.2 Other Symbols Symbols for minimum / maximum value display Battery level indicator Physical units depending on measuring mode Symbol water activity Material index and...
  • Page 16: Switching The Device On And Off

    Switching the Device On and Off The device is switched on and off by pressing the "On / Off" button . The device starts in the measuring menu or main menu. The measuring process can be carried out here [see Chapter 5.3.1 "Measuring Menu (Main Menu)"].
  • Page 17: Measuring Menu (Main Menu)

    5.3.1 Measuring Menu (Main Menu) After switching on, the device is in the measuring menu (main menu). The other menus can be accessed from here by pressing the "Up" or "Down" buttons. In the measuring menu, the last measured values are displayed according to the measuring mode selection made with the associated units and the note "Hold".
  • Page 18 The device must be switched on and in the main measuring mode to be able to make the measuring mode settings. Press the "Down" button once to access the measuring mode selection. If the setting for the measuring mode should be changed now, the "M" button must be pressed briefly (<...
  • Page 19 Measuring mode "air temperature, t" (rh / t / t): relative humidity (in r.H.%), temperature (in °C) and the measuring mode symbol "t" are displayed. Figure 5-9: Measuring mode Figure 5-10: Measuring selection "air temperature, t" menu "air temperature, t" Measuring mode "Dew point, Dp"...
  • Page 20 Measuring mode "absolute humidity, Ah" (rh / Ah): The relative humidity (in r.H.%), the absolute humidity (in g/m³, i.e. grams of water in 1m³ of air) and the measuring mode symbol "Ah" are displayed. Figure 5-15: Measuring Figure 5-16: Measuring menu mode selection "absolute "absolute humidity, Ah"...
  • Page 21 Measuring mode "water activity, Aw" (t / Aw / Aw): The temperature (in °C), the water activity (Aw) and the measuring mode symbol "Aw" are displayed. Figure 5-22: Measuring Figure 5-21: Measurement mode selection "water menu "water activity, Aw" activity, Aw" Measuring mode "building materials"...
  • Page 22: Maximum Value Display

    5.3.3 Maximum Value Display Measuring menu Press Down button twice The highest measured value of a measurement series is displayed together with the "Max" display symbol. A dash at the position of the measured value indicates that there is no maximum value (yet). If an existing maximum value should be deleted, the displayed value must be selected by briefly (<...
  • Page 23: Minimum Value Display

    5.3.4 Minimum Value Display Press Down button 3 times Measuring menu The lowest measured value of a measurement series is displayed together with the “Min" display symbol. A dash at the position of the measured value indicates that there is no minimum value (yet). If an existing minimum value should be deleted, the displayed value must be selected by briefly (<...
  • Page 24: Memory Menu

    5.3.5 Memory Menu Press Down button 4 times Measuring menu The ring memory symbol "o" and the corresponding memory location number are displayed. As soon as you select the memory menu, the memory location number "o1" is displayed for approx. 1 second, and then the last measured saved value contained there is displayed.
  • Page 25: Other Functions

    6 Other Functions 6.1 Automatic Switch-Off If no button is pressed within approx. 90 seconds, the device switches off automatically. The current values are retained and are displayed again after the device is switched on again. 6.2 Battery Monitoring If the battery symbol is shown in the display, the battery is dead and must be replaced.
  • Page 26: Installation Of The Pc-Software Gann Dialog Pro

    Minimum screen resolution 1280 x 800 (1920 x 1080 is recommended) Internet connection for software downloads, updates and upgrades The PC software GANN Dialog Pro is available for download free of charge at the following link: http://download-ota.gann.de/dlg Detail information about the PC software GANN Dialog Pro can be found in the associated user manual.
  • Page 27 BL Compact RH-T Hydromette-Settings Check for a BL Compact RH-T firmware update! Install the Hydromette BL Compact RH-T Drivers BL Compact RH-T Drivers Figure_7_2: Download device drivers of the Hydromette BL Compact RH-T To download the device drivers, the working range of the desired Hydromette must first be selected in the menu item "Select working range".
  • Page 28: Usb-Communication With A Pc

    8 USB-Communication with a PC The software "GANN Dialog Pro" must be installed before the Hydromette BL Compact RH-T is connected to a PC (see chapter 7, Figure 7-1). GANN Dialog Pro includes the associated device drivers, which must also be installed (see chapter 7,...
  • Page 29: Application Notes

    9 Application Notes 9.1 General Notes on Humidity / Air Temperature Measurement Humidity, also known as air humidity, is the water vapour content of the air. Like any other substance, air only has a limited capacity to absorb water. This limit is known as the saturation limit. Above the saturation point, the excess water content accumulates in the form of very fine water droplets (condensate).
  • Page 30: Using The Hydromette Bl Compact Rh-T

    9.2 Using the Hydromette BL Compact RH-T Measure: Press and hold the "M" button for longer than 2 seconds. A measurement process is carried out as long as the Measure button is kept pressed. After releasing the "M" button, the measurement process is interrupted and the "Hold"...
  • Page 31: Precautions

    9.2.1 Precautions The sensor can be irreparably damaged by various mechanical or environmental influences. These include in particular: direct contact of the sensor with the fingers direct contact with solid or sticky materials or objects measurement in environments containing solvents, oil vapours or other high levels of contaminants storing the sensor in foam materials NOT provided by us removal from the drill hole too hastily.
  • Page 32: Equilibrium Wood Moisture Content (Emc)

    9.4 Equilibrium Wood Moisture Content (EMC) Equilibrium wood moisture content is the moisture content adopted by the wood when it is exposed to constant climate (constant humidity and constant temperature) for sufficiently long time. The device can simultaneously display relative humidity, temperature, and equilibrium wood moisture content.
  • Page 33: Dew Point Temperature

    9.7 Dew Point Temperature The dew point temperature is the temperature at which the air is saturated with water vapour. The relative humidity is then 100%. If this dew point temperature is undershot, the moisture contained in the air condenses on a component / surface. The dew point temperature is generally lower than the air temperature, except at 100% R.H.
  • Page 34: Wet-Bulb Thermometer

    9.9 Wet-Bulb Thermometer The wet-bulb temperature is the lowest temperature that can be achieved with evaporative cooling. The release of water from the damp surface is in balance with the ability of the surrounding atmosphere to absorb water and thus saturates the surrounding air with water vapour. Because of the evaporative chill, the wet-bulb temperature is dependent on the relative air humidity and lies under the air temperature.
  • Page 35: Measuring The Relative Air Humidity In Building Materials

    9.10 Measuring the relative Air Humidity in Building Materials The method for measuring the relative air humidity/equilibrium moisture content in screeds has been used for a long time in Great Britain and the Scandinavian countries. Compared to the non- destructive measurement or the resistance measurement, it is, however, more time-consuming and requires suitable drilled holes.
  • Page 36: Drill Hole" Method

    9.10.1 "Drill hole" Method For the measurement, a hole with a diameter of min. 7 mm or 8 mm (flex) and a depth of at least 40 mm is drilled. A sharp drill bit, a high impact rate and a low speed are important. If the drill hole is very hot, wait for the temperature to equalise before measuring.
  • Page 37: Accessories

    10 Accessories Connection cable MK 26 – Length: 1.80 m (order no. 31016920) For device connection to a USB port. Sintered filter Inner Ø 6.5 mm / outer Ø 10 mm (order-no. 31014602) for models RH-T flex 250/350 Filter cap for protection in dusty air and for measurement at high air velocities. ®...
  • Page 38: Appendix

    11 Appendix 11.1 Material-Table Material index Material Cement screed in weight % Anhydrite screed in weight % Concrete in weight % Cement mortar in weight % Gypsum plaster in weight % Lime sand brick in weight % Lime cement mortar in weight % wood fibre insulation panels in weight % Mineral wool insulation in weight % Brick in weight %...
  • Page 39: Dew Point Table

    11.3 Dew Point Table Air- Dew point temperature in °C at a relative humidity Saturation temperature moisture = amount of water 30 % 40 % 50 % 60 % 70 % 80 % 90 % °C in g/m³ °C °C °C °C °C...
  • Page 40: Equilibrium Moisture Values In Percent By Weight

    11.4 Equilibrium Moisture Values in Percent by Weight at 20°C at 20°C at 20°C Building materials approx. 50% RH approx. 65% RH approx. 90% RH Cement screed (sealed, 1.7 - 1.8 applied rel. dry) Cement screed (unsealed, 2.4 - 2.6 applied rel.
  • Page 41: Comparison Graph Of Humidity - Material Moisture Content

    11.5 Comparison Graph of Humidity – Material Moisture Content Relative humidity in % hputz % Moist Moist Normal Normal Wood moisture content Wood moisture content (Softwood) % (Softwood) % Mixed plaster % Mixed plaster % Gypsum plaster % Fungus attack Outside moisture range Normal room moisture Central heated room...
  • Page 42: References

    11.6 References We would like to specifically draw your attention to the fact that the literature mentioned is only an extract and is not complete. The individual titles must also be viewed with regard to the respective usage case. Trocknungstechnik, Erster Band, Springer-Verlag, Berlin, ISBN: 3-540-08280-8 Wassertransport durch Diffusion in Feststoffen, H.
  • Page 43: Eu Declaration Of Conformity

    EU Declaration of Conformity Document no. / order no.: 30012046 HYDROMETTE BL Compact RH-T flex 350 Product identifier: We declare that the hand-held meter and related accessory correspond with the protection requirements and if used according to their intended purpose, comply with the requirements of the directives: ☒...