IMPORTANT SAFETY INFORMATION WARNING 4) The outlet point of this heater, hose and 1) Check the RCD in this heater (refer A) & the handshower act as a vent. They must not RCD at the main switch board (refer B) of the premise at least once a month.
Page 4
CENTON and its technicians will also not be liable to reimburse back any damages or replacement cost for such removal works. SAF EGUAR DI NG THE ENVI RONMENT This product may not be treated as household waste.
HEATER CONTENTS CHECKLIST 3 x Wall Plugs & Screw Set 1 x Heater Unit 1 x Instruction Manual & Accessory Set Content Checklist * Please refer to the Accessory Set Content Checklist (separate printed attachment).
PART DESCRIPTION MODEL: VINTAGE VT555 / VINTAGE VT555E / VINTAGE VT555EP Heater Cover 11. Mounting Holes (3 Nos) Power Indicator 12. Flow Switch Assembly RCD Indicator 13. Water Inlet Temperature Control Knob 14. Double Function Manual RCD Test Button Reset Thermostat RCD Reset Lever 15.
Page 7
PART DESCRIPTION MODEL: VINTAGE VT555ESP Heater Cover 11. Electronic Control Unit Power Indicator 12. Mounting Holes (3 Nos) RCD Indicator 13. Flow Switch Assembly Temperature Control Knob 14. Water Inlet RCD Test Button 15. Double Function Manual RCD Reset Lever Reset Thermostat Cable Clamp 16.
ELECTRICAL REQUIREMENT WARNING THIS APPLIANCE MUST BE EARTHED Note: An approved type of Residual Current Device (RCD) of 10mA sensitivity should be installed in conjunction with the heater. Installation must be carried out by a qualified electrician. The shower heater unit must be connected to its own independent electrical circuit. Lead the power cable from the indoor fuse distributor board or Miniature Circuit Breaker (MCB) to an ‘ON/OFF’...
WATER REQUIREMENT PLUMBING SCHEMATIC DIAGRAM Diagram on right shows a typical system layout. Cold water system Do not use joining compounds on any pipe fittings for the installation. Stop valve The unit works at minimum water flow rate of 2 litre/min. An incoming water flow rate of 5 litre/min and above would excel its Minimum performance.
INSTALLATION PROCEDURES FIXING THE SHOWER TO THE WALL CAUTION: It is important to mount the shower unit to a flat surface otherwise difficulty may be encounter when fitting the cover and subsequent. Unscrew the screw at bottom of heater and remove the cover by lifting the bottom of cover upward.
Page 11
INSTALLATION PROCEDURES PLUMBING CONNECTIONS CAUTION: Complete the process before wiring connection Connect the water supply to the inlet of stop valve via 15mm plastic pipe using a 15mm x 15mm elbow compression fitting. Note: i) DO NOT apply excessive force when making these connections.
OPERATING THE SHOWER Warning Improper earthing may results in mulfunctioning to the RCD & harmful to user. Never use the heater if there is doubt on the Earthing installation. 1. RCD 2. Press once on the stopvalve round button to Switch on the heater switch outside the bathroom.
USER MAINTENANCE THINNER CLEAN FILTER REGULARLY The spray head & filter must be descaled regularly in order to maintain the performance of the shower. Filter Mesh a) - Disconnect the sprayhead from the hose. Washer - Remove filter and clean it using a soft brush. - Wash it under running water.
QUALITY ASSURED Centon heaters are tested before leaving the factory. With proper care and usage, the heaters are durable, safe and reliable. Use only accessories recommended by the manufacturer. WARNING The appliance must be earthed. Do not use plumbing cement on connection. If necessary, use only thread or sealant tape.
TEMPERATURE RISE GUIDELINE Outlet Water Temperature Inlet Water Temperature Water Temperature Rise Water temperature rise depends on 3 factors: Inlet Water Temperature Heating Element Power Water Flow Rate Inlet Water Temperature Water Temperature Rise Heating Element Power Water Temperature Rise Water Flow Rate Water Temperature Rise High...
SPECIFICATION Model Electrical Rating – Available in 3.0kW - 6.0kW, 220-240Vac, 50/60Hz Minimum Water Flow Rate – 2 liters/ min Minimum Water Inlet Pressure (Open Outlet) – 20kPa (0.2bar / 2.9psi) Maximum Water Inlet Pressure (Open Outlet) – 0.38MPa (3.8bar / 55psi) Shower Temperature Control –...
Page 17
SPECIFICATION Model Electrical Rating – Available in 3.0kW - 6.0kW, 220-240Vac, 50/60Hz Minimum Water Flow Rate – 2 liters/ min Minimum Water Inlet Pressure (Open Outlet) – 20kPa (0.2bar / 2.9psi) Maximum Water Inlet Pressure (Open Outlet) – 0.38MPa (3.8bar / 55psi) Shower Temperature Control –...
ACCESSORY INSTALLATION Full Shower Accessory Fix the rotatable Soap Dish and Shower Holder onto the Sliding rail as illustrated. Determine the suitable height for shower accessories and mark for the mounting holes. Mounting holes are available after Rail Support Caps are removed. Drill the mounting holes and insert Wall Plugs provided.
Page 19
ACCESSORY SET CONTENT CHECKLIST 1 x Sliding Rail 1 x Shower Holder 1 x Soap Tray 1 x Handshower 2 x Rail Support 2 x Screw & Wall Plug Set 1 x Filter Mesh Washer 1 x Right Angle Stop Valve 1 x Flexible Hose 1 x Pop Start Stop Valve...
Page 20
ACCESSORY SET CONTENT CHECKLIST 1 x RS Head Shower 1 x RS Separable Rail (A) 1 x Fix Plate A 1 x RS Rail Support 2 x Screw & Wall Plug 1 x Handshower 1 x RS Shower Holder 1 x RS Separable 1 x Filter Mesh Washer Rail (B) 1 x Right Angle Stop Valve...
Page 21
ACCESSORY INSTALLATION Rain Shower Accessory Drill holes & insert wall plugs provided according to the recommended dimension as shown (cater for Fix Plates). Note: Height of the dimension is at the discretion of the user 2. Secure the Fix Plate (A) & (B) with screws provided. Secure the RS Shower Head to RS Separable Rail A.