V33
Multimeter
Thank you for purchasing our equipment. Please read this manual carefully and heed the safety warnings and instructions before
installing, using or repairing the equipment. This will ensure not only the protection of persons, but also the long life of the equipment.
Introduction
This multimeter has been designed as a highly stable, reliable and comprehensive digital multimeter in a compact size with drop
protection. It features a built-in 40mm LCD display with large characters for clearer readings and a precision A/D converter that forms
the core of a large integrated circuit. As a result, this model allows measurement of AC/DC voltage, AC/DC current, resistance, diodes,
continuity, temperature, frequency, capacitance, NCV detection, live wire recognition, and provides analog column display and low
impedance measurement functions. The built-in EBTN display provides clear and readable readings from any angle. To make full use
of this multimeter, retain this instruction manual.
1. Induction position of NCV
2. EBTN display: 51.5*40 mm
3. Function buttons
- SEL: press lightly to activate scroll function, below ACV range and press and hold to enter VFC mode
- MAX/MIN: press lightly to scroll MAX/MIN, hold down MAX/MIN to exit.;
- REL: under capacity range and press slightly to activate relativity mode
4. Rotary switch for function selection
5. Input connectors
6. Rubber protective sleeve
Safety information
This multimeter has been designed in accordance with IEC1010 standard for electronic measuring instruments with 600 V CAT III
voltage and 2 contamination.
This symbol indicates that the operator must follow the explanation in the operating instructions to avoid personal injury or damage
to the measuring instrument.
Grounding
High Voltage
Warning:
-
Improper use of this equipment may cause damage and electric shock. Read this manual before using the equipment.
-
Always disconnect the cables before changing the battery or fuses.
-
Before using the device, check the condition of the measuring cables and the meter itself for damage.
-
Use extra caution when making measurements if the voltage is higher than 30 VAC RMS or 60 V DC, these voltages are considered
an electrical shock hazard.
-
Always discharge the capacitors and disconnect the device under test from the power supply before performing diode, resistance
or continuity tests.
-
To avoid damage to the measuring instrument, do not exceed the maximum input limits specified in the specification.
-
If the device will not be used for a long period of time, remove the batteries to prevent them from draining.
Maintenance
-
To prevent electric shock, disconnect the test leads from the power source before removing the back cover or battery cover or
fuses.
-
To prevent electric shock, do not use the meter until the battery and fuse covers are in place and securely fastened.
-
To protect the circuit, replace the fuse, it must be in the same specification.
-
Do not clean the measuring instrument housing with chemical solvent.
Double Insulation

Advertisement

loading
Need help?

Need help?

Do you have a question about the V33 and is the answer not in the manual?

Questions and answers

Summary of Contents for Solight V33

  • Page 1 Multimeter Thank you for purchasing our equipment. Please read this manual carefully and heed the safety warnings and instructions before installing, using or repairing the equipment. This will ensure not only the protection of persons, but also the long life of the equipment. Introduction This multimeter has been designed as a highly stable, reliable and comprehensive digital multimeter in a compact size with drop protection.
  • Page 2: Technical Parameters

    Technical parameters Accuracy: ± (% of reading + digits), warranty period: 12 months Ambient temperature: 18℃ ~ 28℃ ; humidity:≤ 80%. Maximum distance between input voltage and earth: CATIII 600V Fuse: CAT 600: F500mA/250V, F10A/250V Battery: 2 x 1.5V AAA Automatic shutdown: approx.
  • Page 3: Voltage Measurement

    Capacity Scope Resolution Accuracy 40nF 0.01nF ±4.0%±25 400nF 0.1nF 4µF 0.001uF ±4.0%±15 40µF 0.01µF 400µF 0.1µF 0.001mF ±5%±25 Overload protection:250V DC or 250V AC RMS Diode test & circuit continuity Scope Resolution Buzzer Built-in buzzer sounds when resistance is less than 50Ω±30Ω Diode Display of approximate forward diode voltage...
  • Page 4 Frequency measurement 1. Insert the black measuring cable into the "COM" connector and the red measuring cable into the "VΩHz" connector. 2. Touch the probe tips of the test leads to both sides of the signal source under test and read the value on the LCD display. Diode, resistance and continuity measurements 1.
  • Page 5 The product has been issued with a CE declaration of conformity in accordance with the applicable regulations. On request from the manufacturer: info@solight.cz, or downloadable from www.solight.cz/en. Solight Holding, s.r.o., Na Brně 1972, Hradec Králové 500 06, Czech Republic.