  • Page 1 GR120S AIR CONDITIONER CLIMATISEUR AIRCONDITIONER CONDIZIONATORE D'ARIA AIRE ACONDICIONADO KLIMATIZAČNÍ ZAŘÍZENÍ KLIMATIZAČNÉ ZARIADENIE KLİMA CİHAZI...
  • Page 3 MODEL GR120S MOBILE AIR CONDITIONER INSTRUCTION MANUAL...
  • Page 4: Electrical Connection (Uk Only)

    ELECTRICAL CONNECTION (UK ONLY) For your safety please read the following information. Warning: This appliance must be earthed. The appliance must be connected to a 220-240 volts 50 cycle AC supply by means of a three pin socket, suitably earthed. The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse.
  • Page 5 WARNINGS: • Only use in the upright position on a flat level surface and at least 50cm from the wall or any objects. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety.
  • Page 6: Identification Of Parts

    IDENTIFICATION OF PARTS Front View Rear View...
  • Page 7: Control Panel

    Accessories Exhaust adapter Exhaust hose Bushings Drain hose Bracket Hose clamp (2) Screw Rubber plug for drain hose CONTROL PANEL...
  • Page 8: Remote Control

    REMOTE CONTROL The functions can be performed by pressing the buttons either on the control panel of the unit or on the remote. ON/OFF button MODE: Press the button repeatedly to select the desired operating mode. AUTO (only shown in the remote display) COOL DEHUMIFICATION HEAT...
  • Page 9 : AIR DIRECTION button Press the button to initiate the upward or downward swing of the louver. : X-FAN button After the unit has been turned off, the X-Fan function allows the fan to operate to eliminate excess moisture from indoor unit to avoid build of mould.
  • Page 10: Lock Function

    The sleep function is not available in AUTO and FAN modes. Press the button to activate the sleep function and “ ” will be shown on the remote display. In COOL and DEHUMIDIFICATION modes, the setting temperature will increase by 1 degree after 1 hour and increase a further 1 degree after 2 hours.
  • Page 11: Maintenance

    Air conditioning installation To install through the window, put the exhaust hose assembly outside the window when the unit is in use. To install through the wall, cut a hole in the wall then connect the exhaust hose and bushings. Feed the exhaust hose through the wall.
  • Page 12 When the tank is full, the unit will beep 8 times and “H8” will be shown on the display. 1. Turn off the unit. 2. Position a container under the drain hole. 3. Remove the rubber plug from the drain hole or hose. The condensed water will drain out. 4.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Symptom Possible Cause and Solution Unit does not run. • The protector trip or fuse is blown. Please wait for 3 minutes and try again, protector device may be preventing unit to work. • Batteries in the remote control exhausted. •...
  • Page 14 SPECIFICATIOINS 220-240~ 50Hz Power supply 3500W Cooling capacity 2000W Heating capacity 1340W Cooling power input 1550W Cooling rated input 2200W Heating rated input 1200x2W Heater power 3.8/1.2MPa Pressure (Discharge/Suction) 5.8MPa Maximum allowable pressure 58dB(A) Sound pressure level R410A Refrigerant 0.8 kg Refrigerant charge Electronic switch 0.5~24 hours Timer...
  • Page 15 MODÈLE GR120S CLIMATISEUR MOBILE MODE D’EMPLOI...
  • Page 16 MISE EN GARDE: • Cet appareil doit toujours être posé debout, sur une surface plane et régulière ; aucun mur ou objet ne doit être situé à moins de 50 cm. Ne jetez pas les batteries dans un feu, le danger d'explosion. •...
  • Page 17 DESCRIPTION Vue avant Air outlet = Sortie d’air Control panel = Panneau de contrôle Handle = Poignée Remote box = Boîte de la télécommande Vue arrière...
  • Page 18: Panneau De Contrôle

    Exhaust air outlet = Sortie d’air Lower air inlet = Arrivée d’air (basse) Upper air inlet = Arrivée d’air (haute) Accessoires Adaptateur d'évacuation Tuyau d'évacuation Bagues de raccordement Tuyau de vidange Support Collier de serrage du tuyau (2) Bouchon du tuyau de vidange PANNEAU DE CONTRÔLE COOL mode = mode CLIMATISEUR HEAT mode = mode RADIATEUR...
  • Page 19 TÉLÉCOMMANDE Chacune des fonctions de l'appareil peut être activée aussi bien avec la télécommande qu'avec le panneau de contrôle situé sur l'appareil. Bouton Marche/Arrêt MODE : Appuyez de manière répétée sur ce bouton pour sélectionner le mode de fonctionnement souhaité. AUTO (n'apparaît que sur l'écran de la télécommande) CLIMATISEUR DÉSHUMIDIFICATION...
  • Page 20 Remarque : Le ventilateur n'est pas disponible en mode DÉSHUMIDIFICATION. : Bouton DIRECTION D'AIR Appuyez sur ce bouton pour lancer le mouvement d'oscillation vers le haut ou vers le bas. : Bouton X-FAN Une fois l'appareil éteint, la fonction X-FAN permet de faire fonctionner le ventilateur de manière à éliminer l'excès d'humidité...
  • Page 21: Fonction Verrouillage

    : Bouton SOMMEIL Ce bouton active une fonction permettant de stabiliser la température de la pièce de manière à ce qu'elle ne devienne ni trop basse ni trop élevée pendant que vous dormez. La fonction sommeil n'est pas disponible dans les modes AUTO et VENTILATEUR. Appuyez sur le bouton pour activer la fonction sommeil.
  • Page 22: Entretien

    Installation du climatiseur Pour une utilisation à travers une fenêtre : Mettez le bout du tuyau d'évacuation à la fenêtre avant d'allumer l'appareil. Pour une utilisation à travers un mur : Percez un trou dans le mur puis connectez le tuyau d'évacuation et les bagues de raccordement.
  • Page 23 Rubber plug = Bouchon en caoutchouc Drain hole = Trou de vidange Hose clamp = Bague de serrage Bracket fixed with a screw = Support fixé avec une vis Quand le réservoir est plein, l'appareil sonne 8 fois et l'écran affiche "H8". 1.
  • Page 24: Dépannage

    DÉPANNAGE Symptôme Cause possible et solution L’appareil ne fonctionne pas. • Le fusible a sauté. Le dispositif de protection empêche peut-être l'appareil de fonctionner. Attendez 3 minutes, puis réessayez. • Les piles de la télécommande sont épuisées. • L'appareil est mal branché. L'appareil s'arrête.
  • Page 25: Spécifications

    SPÉCIFICATIONS 220-240~ 50Hz Alimentation 3500 W Capacité de refroidissement 2000W Capacité de chauffage 1340W Puissance frigorifique absorbée 1550W Puissance nominale de refroidissement 2200W Puissance nominale de chauffage 1200x2W Puissance du radiateur 3,8/1,2MPa Pression (refoulement/aspiration) 5,8 MPa Pression maximale autorisée 58 dB(A) Niveau de pression acoustique R410A...