Kanomax 6822 User Manual

Volume flow anemometer

Advertisement

Quick Links

219 Route 206
PO Box 372
Andover, NJ 07821 USA
6822
User Manual, PN 10282
Rev 1.0, 30-July-2021
Copyright © 2021, Kanomax USA, Inc.
TM
Model 6822
VOLUME FLOW
ANEMOMETER
User Manual
Phone: 1-800-247-8887
Fax:
(973) 786-7586
info@kanomax-usa.com
Kanomax USA, Inc
www.kanomax-usa.com
Page 1 of 32
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6822 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kanomax 6822

  • Page 1 PO Box 372 Fax: (973) 786-7586 Andover, NJ 07821 USA info@kanomax-usa.com Model 6822 ™ VOLUME FLOW ANEMOMETER User Manual 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 1 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 2 Andover, NJ 07821 USA info@kanomax-usa.com INTRODUCTION Congratulations on your purchase of a 6822 Digital Anemometer with Volume Calculation! You now own one of the most accurate, dependable, and highly regarded airflow measurement instruments available today. Kanomax’ s model 6822 digital anemometer is a versatile instrument for measuring air velocity in various applications such as HVAC, aerospace development, industrial process airflow, and fluids research.
  • Page 3: Warranty

    Andover, New Jersey 07821 Please include a note with name, address, telephone number and description of the problem. Although we provide assistance on Kanomax products both personally and through our literature, it is still the total responsibility of the customer to determine the suitability of the product for use in their application.
  • Page 4: Important Safety Information

    However, there is no guarantee that interference will not occur in a particular situation. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 4 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 5 WEEE – Waste Electrical and Electronic Equipment 2002/96/EC Kanomax asks that all our products to be recycled at the end of their current use, to comply with local waste requirements. Kanomax supports local Waste Electrical and Electronic Equipment (WEEE) directives where they are in operation.
  • Page 6 Dropping the instrument or the probe may cause damage or malfunction to the instrument and may change the calibration data. We recommend sending it in immediately to be checked. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 6 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 7 When storing or shipping the instrument, the manufacturer recommends disconnecting the cable(s) and returning it to the original carrying case. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 7 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 8: Section 1 - Specifications

    Approx. 150 hours, without backlight Battery check: Automatic low battery display Display: 0.5” LCD, 4 digits, with LED backlight 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 8 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 9 (installed in instrument) (1) Hard-shell carrying case with foam liner • (1) 6822 operation manual • Dimensions INSTRUMENT 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 9 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 10 Phone: 1-800-247-8887 PO Box 372 Fax: (973) 786-7586 Andover, NJ 07821 USA info@kanomax-usa.com AP275 PROBE AP100 PROBE 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 10 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 11: Section 2 - Switch Functions

    3 seconds. The LCD will flash. The backlight is now switched on permanently. To switch the backlight off, press the backlight key again. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 11 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 12 MAX/MIN key was pressed, and the sample rate is set to 16 seconds. To exit MAX/MIN mode, press the SAMPLE RATE key. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 12 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 13 Χεντ . Pressing “SET” will accept the currently displayed value and advance you to the next menu. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 13 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 14 Entry menu. Press the “ADJ” key to enter the Height Entry menu. The Height can now be edited one digit at a time. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 14 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 15 This will give a more accurate value for the volume flow rate out of the duct.) The following page shows a graphical representation of the steps required to enter the duct dimensions into the 6822. 6822 ™...
  • Page 16 219 Route 206 Phone: 1-800-247-8887 PO Box 372 Fax: (973) 786-7586 Andover, NJ 07821 USA info@kanomax-usa.com 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 16 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 17 Note: When CUBIC and MPS are displayed on the LCD display, the reading displayed is in units of CUBIC METERS PER HOUR. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 17 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 18: Section 3 - Operational Notes

    9999 cubic feet per minute (CFM) or 9999 cubic meters per hour (CMH) the result cannot be displayed by the instrument. The out- of-range error is displayed. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 18 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 19: Appendix A - Lcd Display Symbols

    (973) 786-7586 Andover, NJ 07821 USA info@kanomax-usa.com APPENDIX A – LCD DISPLAY SYMBOLS APPENDIX B – BATTERY REPLACEMENT 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 19 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 20: Appendix C - Airflow Volume Calculations

    Step 3: Volume flow = Air Velocity x Area, therefore, Volume flow rate = 450 FPM x 2 sq ft. = 900 CFM. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 20 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 21: Appendix D - Analog Voltage Outputs

    ► With the additional error associated with the analog output voltage, the effective accuracy of the analog output for this air velocity measurement will be ±2% of reading ±1 digit (±11 FPM). Custom Analog Voltage Outputs are also available – contact Kanomax for details. 6822 ™...
  • Page 22 Analog Output circuit block diagram and connector pin assignment Mating Cable Connector: Binder Part No. 99-0413-00-05 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 22 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 23: Appendix E - Usb Data Output (If Equipped)

    For Windows users, open the Windows Device Manager (found in Control Panel) and verify that a USB serial port exists as shown below. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 23 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 24 NOTE: Units with USB or RS232 communications, output only Air data at this time. Temperature data is not available on the output. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 24 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 25: Appendix F - Rs232 Communications (If Equipped)

    You are now ready to capture the data being measured by your instrument. Please refer to Appendix G – Viewing and Capturing Data for further instructions. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 25 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 26: Appendix G - Viewing And Capturing Data

    There are many terminal emulator programs available on the market. It is up to the end-user to determine which program is compatible with his/her system, what settings it may require and the Kanomax product being used. Kanomax does not endorse or recommend any of these programs and assumes no liability for their use.
  • Page 27 You will now receive data from your instrument. The graphic below shows the serial port output data from Parallax Serial Terminal when connected to a Kanomax 6822 Instrument. CFM was selected part way through. Graphics may vary. Serial Port Settings 6822 ™...
  • Page 28 Measurement Units Same as Units shown on LCD Display Below are examples of the formatted output data for Kanomax 681x Instruments (units may be different depending on the units selected on the LCD display): Model 6822 displaying in Air Velocity Mode:...
  • Page 29 Andover, NJ 07821 USA info@kanomax-usa.com Exporting and Graphing Data Exporting serial port instrument data from the Kanomax instrument to a spreadsheet application such as Microsoft Excel or OpenOffice Calc allows the data to graphed or recorded. The simplest way to export the instrument data is to use a terminal emulator...
  • Page 30 Duct 2 Duct 3 Duct 4 Duct 5 Duct 6 Duct 7 Duct 8 Duct 9 Notes: 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 30 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 31 Please contact us or visit our website for the latest information on calibrating your instrument. 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 31 of 32 Copyright © 2021, Kanomax USA, Inc.
  • Page 32 219 Route 206 PO Box 372 Andover, New Jersey 07821 (800) 247-8887 Fax: (973) 786-7586 info@kanomax-usa.com www.kanomax-usa.com Copyright © 2021, Kanomax USA, Inc 6822 ™ User Manual, PN 10282 Kanomax USA, Inc Rev 1.0, 30-July-2021 www.kanomax-usa.com Page 32 of 32...

This manual is also suitable for:

6822-s6824-s6825-s

Table of Contents