Beurer MG 40 Manual

Items included in the package

Check that the exterior of the delivery cardboard packaging is intact and make sure that all components are present. Before use, ensure that there is no visible damage to the device or accessories and that all packaging material has been removed. If you have any doubts, do not use the device and contact your retailer or the specified Customer Service address.
1 x Infrared Massager
4 x Interchangeable massage attachments
1 x These operating instructions

Explanation of symbols

The following symbols are used in the operating instructions and on the type plate:

Warning of risks of injury or health hazards.
Safety information about possible damage to appliance/accessories.
information Note
Important information
The unit is double-protected and thus corresponds to protection class 2.
Read the instructions for use
Manufacturer
Dispose of packaging in an environmentally friendly manner
Please dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment).
This product satisfies the requirements of the applicable European and national directives.
The products demonstrably meet the requirements of the Technical Regulations of the EAEU.
Only use indoors.
United Kingdom Conformity Assessed Mark

Description of device

Overview

  1. Pivot for massaging head
  2. Rotary knob for adjusting the angle of the handle (4 settings)
  3. Slide switch
  4. Infrared surface
  5. Massaging surface
  6. Massage fittings

Initial use

Use the sliding switch to select the desired function:

Position
0 Off
M Vibrational massage
W IR heat for deep results
W + M IR heat massage

Use

IR heat/IR heat massage

Push the switch to 'W' to heat up the infrared area. This now starts to light up. After a few minutes, it is heated up and ready for use.

If the infrared area is heated up for a relatively long period without any skin contact, you may find the temperature uncomfortably high. Before application, please therefore always check the temperature of the infrared area with your fingertips. Switching off the infrared heat briefly can reduce the temperature.
When the temperature of the infrared area is correct, set the switch to 'W + M'. You can now start the infrared heat massage.
All parts of the body can be reached easily thanks to the pivoted joint of the massaging head and the possibility of adjusting the angle of the handle. The handle can be adjusted to 4 different settings by pressing the knob (Fig., no. 2).

Massage

Without exerting pressure, massage using slow, circular movements. Keep the skin taut to achieve optimum results.
Pictures are showing ideal massage directions:
Ideal massage directions

To intensify the massage, we recommend the following massage heads:

  1. Brush fitting: for intensive skin massages - very pleasant, circulation - stimulating effect
  2. Knobbed fitting 2: for intensive and localised deep massages - particularly soothing after physical exertion
  3. Knobbed fitting 1: for intensive massages to relieve muscle pain and tension
  4. Tapered fitting: for intensive and localised deep massages - particularly soothing after physical exertion

Without the head, the massager is mainly used to massage sensitive parts of the body and to generate IR heat.

Cleaning and maintenance

Cleaning

  • Switch off the device each time before cleaning.
  • Clean the device with a slightly damp cloth only.
  • Clean the device using only the methods specified. Under no circumstances may liquid enter the device or accessories.
  • Do not use the device again until it is completely dry.
  • Do not clean the device in a dishwasher.
  • Do not use any abrasive cleaning products or hard brushes.

Pull out the plug before cleaning.
Wipe the massager with a damp cloth and then dry it. Do not use any scouring agents or solvents to clean the massager. The massage heads may be cleaned in warm, soapy water.
Only re-use the IR massager when it is completely dry.

Care
If you do not plan to use the device for a long period of time, we recommend that you store it in the original packaging in a dry environment, ensuring it is not weighed down by additional items.

Technical data

Disposal 220-240 V~, 50-60 Hz, 12 W
Dimensions ca. 39.0 x 8.8 x 8.5 cm
Weight ca. 650 g

  • The unit is only intended for domestic/private use, not for commercial use.
  • This device may be used by children over the age of 8 and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.
  • Children must not play with the device.
  • Cleaning and user maintenance must not be performed by children unless supervised.
  • If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed, the device must be disposed of.
  • The surface of the device becomes warm during use. Persons insensitive to heat should be particularly careful.
  • Under no circumstances should you open or repair the device yourself, as faultless functionality can no longer be guaranteed thereafter. Failure to adhere to this instruction will void the warranty.

Worth knowing

Massage can be recommended as a suitable treatment as part of many forms of healthcare, fitness and training. Besides increasing general well-being, it is helpful for muscle aches, muscle tension, circulatory disorders and feelings of fatigue.
The additional warmth of the infrared lamp reinforces the massage effect not only by warming the surface of the skin but also by promoting the circulation. That way the deeper layers of the tissues and muscles are also reached.

Intended use

This device is intended only for the massaging of individual parts of the human body. It cannot replace medical treatment. Do not use the massage device if any of the following warnings apply to you. Please consult your doctor if you are unsure whether or not the massage device is suitable for you.

Use of the massage device is prohibited in the following cases:

  • On animals.
  • Not with changes caused by disease or injury in the back region (e.g. disc problems, open wounds),
  • Under any circumstances for massages in the area around the heart if you wear a pacemaker. If this is the case, consult your doctor regarding other parts of the body first.
  • Never use the massage device on swollen, burned, inflamed or damaged skin or body parts.
  • The massage device must not be used during pregnancy.
  • Do not use the massage device on the face (eyes), on the larynx or on other particularly sensitive parts of the body.
  • Never use the device while you are asleep.
  • Never use the device after taking medication or consuming alcohol (reduced levels of awareness).
  • On bones (e.g. joints, spine).
  • In a vehicle.
  • In the pubic area.

You should consult your doctor before using the massage device if:

  • you suffer from a serious illness or are recovering from an operation on the upper body,
  • you are fitted with a cardiac pacemaker, implant or other aid,
  • Thromboses,
  • Diabetes,
  • in case of pains of unclarified origin.

The device is only intended for the purpose described in these operating instructions. The manufacturer cannot be held liable for damage occurring as a result of inappropriate or careless use.

Warnings and safety notes

Please read these operating instructions carefully. Failure to observe the information provided below can lead to personal injury or material damage.

Keep children away from the packaging materials. Risk of suffocation.

Electric shock

Just like any other electrical appliance, this massage device must be handled with due care and attention in order to prevent the risk of electric shock.
For this reason, the device must only be operated as follows:

  • with the mains voltage specified on the device only,
  • never use the device if any damage to the appliance itself or to any of its accessories is evident,
  • never during a thunderstorm.

In the event of defects or operational faults, switch the device off immediately and, if applicable, disconnect it from the mains socket. Never pull on the power cable or on the appliance in order to disconnect the plug from the mains outlet. Never hold or carry the device by the power cable. Keep the cables away from hot surfaces. Never open the device for any reason.
Make sure that the massage device, the plug and the cable do not come into contact with water or other fluids.
For this reason, the device must be operated as follows:

  • only in dry inside rooms,
  • only with dry hands,
  • never in the bath, in the shower or near a filled basin,
  • never in swimming pools, whirlpools or in the sauna,
  • never out in the open.

Never try to retrieve the device if it falls into water. Disconnect the plug immediately from the mains outlet.
Do not use the device if damage to the device itself or any of its accessories is evident.
Do not subject the device to any impact and do not drop it.

Repairs

Repairs to electrical appliances must only be carried out by qualified persons. Incorrect repairs can lead to considerable danger for the user. In the event of repairs, please contact our customer service or an authorised dealer.

Fire hazard

There is a risk of fire if the device is used incorrectly or if it is not used according to these operating instructions.
For this reason, the massage device must only be operated as follows:

  • Never operate the massage device for longer than 15 minutes (risk of overheating) and allow it to cool off for 15 minutes before using it again.
  • Never leave the device unsupervised, particularly if children are around.
  • Never use the device under covers, such as blankets or pillows.

Handling

Switch the device off and disconnect the power supply after every use and before every cleaning.

  • Make sure that no hair can get caught in the device.
  • Avoid contact with sharp or pointed objects.
  • Do not kink the cable.
  • Make sure that the device is not too close to heat sources such as ovens, radiators or direct sunlight.
  • Never insert objects into the device through any openings.
  • Switch off the device and disconnect it from the mains when you are removing or attaching the massage attachments.