SAFETY WARNINGS
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
![]()
If the information in this manual is not followed exactly, a fire or explosion WARNING: may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
- Do not try to light appliance.
- Extinguish any open flame.
- Shut off gas to appliance.
- Service must be performed by a qualified service agency.
This is an unvented gas-fired portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided.
GENERAL HAZARD WARNING
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
![]()
Fuels used in liquefied propane gas appliances, and the products of combustion of such fuel, can expose you to chemicals including benzene, which is known to the state of California to cause cancer and cause birth defects or other reproductive harm, for more information go to www.P65Warnings.ca.gov
![]()
NOT FOR HOME OR RECREATIONAL VEHICLE USE
![]()
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.
![]()
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER, OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER. AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
![]()
THIS PRODUCT CAN EXPOSE YOU TO CHEMICALS INCLUDING LEAD AND LEAD COMPOUNDS, WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. FOR MORE INFORMATION GO TO WWW.P65WARNINGS.CA.GOV.
SPECIFICATIONS
MODEL | MH25CVX | MH80CVX | MH200CVX |
MAX SUPPLY PRESSURE: |
To Regulator MIN | 5PSI (34.5 kPa) | 5PSI (34.5 kPa) | 15PSI (103 kPa) |
To Regulator MAX | Bottle Pressure | Bottle Pressure | Bottle Pressure |
Regulator Out | 11" W.C. (2.74 kPa) | 11" W.C. (2.74 kPa) | 10 PSI (68.9 kPa) |
Ignition | Piezo | Piezo | Piezo |
Min Ambient Temp. | 0˚ F (17.8) ˚C | 0˚ F (17.8) ˚C | 0˚ F (17.8) ˚C |
BTU Rating Low-High | 15,000-25,000 BTU/HR (4.3-7.3 kW) | 30,000-80,000 BTU/HR (8.79-23.4 kW) | 75,000-200,000 BTU/HR (22-58.6 kW) |
Fuel Consumption | 1.58 LBS/HR (.71kg/HR) | 1.4-3.7 LBS/HR (.74-1.8 kg/HR) | 3.5-9.3 LBS/HR (1.44-4.32 kg/HR) |
Hose Length | 10' (304 cm) | 10' (304 cm) | 10' (304 cm) |
VENTILATION: Minimum openings required |
Opening near floor | 2 ft2 | 2 ft2 | 2 ft2 |
Opening near ceiling | 2 ft2 | 2 ft2 | 2 ft2 |
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
FOR QUESTIONS, PROBLEMS, MISSING PARTS BEFORE RETURNING TO RETAILER PLEASE CALL WITH MODEL NUMBER AND SERIAL NUMBER OF HEATER: 1-800-251-0001
MONDAY-FRIDAY 8-5 PM EASTERN TIME OR E-MAIL USING THE MR. HEATER WEBSITE: WWW.MRHEATER.COM
In order to provide the best service possible Mr. Heater is now giving you more ways to get in touch with us:
- FACEBOOK: Find us on Facebook
- TWITTER: Find us on twitter
- YouTube: There are now informational videos on YouTube.
- WEBSITE: Mr. Heater's full line of product are now at WWW.MRHEATER.COM
![]()
FAILURE TO FOLLOW THESE VENTILATION REQUIREMENTS MAY RESULT IN SOOTING DAMAGE.
OPERATING PRECAUTIONS
This is a propane, direct-fired, convection heater. It's intended use is primarily temporary heating of buildings under construction, alteration or repair.
Propane is heavier than air. If propane leaks from a connection or fitting, it sinks to the floor, collecting there with the surrounding air, forming a potentially explosive mixture. Obviously, propane leaks should be avoided, so set up the propane supply with utmost care. Leak check new connections or reconnections with a soap and water solution and follow all connection instructions herein. Also, ask your propane dealer for advice on the propane application and supply installation and ask him to check it if there are any questions.
This heater was designed and certified for use as a construction heater in accordance with ANSI Standard Z83.7/CGA 2.142000. Check with your local fire safety authority if you have any questions about your applications. Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these.
Direct-Fired means that all of the combustion products enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic. We can tolerate small amounts but not a lot. CO can build up in a heated space and failure to provide adequate ventilation could result in death. The symptoms of inadequate ventilation are:
- headache
- dizziness
- burning eyes and nose
- nausea
- dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating instructions.
When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
SAFETY PRECAUTIONS
- Check the heater thoroughly for damage. DO NOT operate a damaged heater.
- DO NOT modify the heater or operate a heater which has been modified from its original condition.
- DO NOT light or operate heater unless the shells are fully extended and locked into position.
- Use only propane gas.
- Use only VAPOR WITHDRAWAL propane supply. If there is any question about vapor withdrawal, ask your propane dealer.
- Mount the propane cylinders vertically (shutoff valve up). Secure them from falling or being knocked over and protect them from damage.
- Locate propane containers the designated distances from heater. Additionally. Do not direct exhaust toward containers.
For USA:
at least 7 ft. (2.13m) for the 25CVX, 80CVX units at least 9 ft. (2.7m) for the 200CVX unit
For Canada:
at least 10 ft. (3m) for the 25CVX, 80CVX, 200CVX unit. ![]()
Use only the hose and regulator assembly provided with the heater. Match the color stripe on the hang tag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Inspect hose assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater. - For indoor or outdoor use. Area must be well ventilated. Figure 1. (Also see "Operating Precautions").
- If at any time gas odor is detected, IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected.
- Install the heater such that it is not directly exposed to water spray, rain and/or dripping water.
- Maintain minimum clearance from normal combustible material (like paper). Figure 2.
- Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing ignition.
- Operate only on a stable, level surface.
- Do not use with duct work. Do not restrict inlet or exit.
- Do not move, handle or service while hot or burning.
- Use only in accordance with local codes or, in the absence of local codes, with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/ NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.
Figure 2
MINIMUM CLEARANCE: From normal combustible material 25CVX, 80CVX, 200CVX
Clearance | Convection |
From sides | 4 ft |
From top | 6 ft |
Locate 10' from canvas or plastic tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind action.
ODOR FADE WARNING
![]()
Asphyxiation Hazard
- Do not use this heater for heating human living quarters.
- Do not use in unventilated areas.
- The flow of combustion and ventilation air must not be obstructed.
- Proper ventilation air must be provided to support the combustion air requirements of the heater being used.
- Refer to the specification section of the heater's manual, heater data plate, or contact the factory to determine combustion air ventilation requirements of the heater.
- Lack of proper ventilation air will lead to improper combustion.
- Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing.
FUEL GAS ODOR
LP gas and natural gas have man‑made odorants added specifically for detection of fuel gas leaks. If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor. ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!
- Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.
- Get everyone out of the building and away from the area immediately.
- Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply valve located at the meter if you use natural gas.
- Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas.
- Use your neighbor's phone and call your fuel gas supplier and your fire department. Do not re-enter the building or area.
- Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier.
- FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you.
ODOR FADING ‑ NO ODOR DETECTED
- Some people cannot smell well. Some people cannot smell the odor of the man-made chemical added to propane (LP) or natural gas. You must determine if you can smell the odorant in these fuel gases.
- Learn to recognize the odor of propane (LP) gas and natural gas. Local propane (LP) gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor.
- Smoking can decrease your ability to smell. Being around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor.
- The odorant in propane (LP) gas and natural gas is colorless and the intensity of its odor can fade under some circumstances.
- If there is an underground leak, the movement of gas through the soil can filter the odorant.
- Propane (LP) gas odor may differ in intensity at different levels. Since Propane (LP) gas is heavier than air, there may be more odor at lower levels.
- Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously.
ATTENTION ‑ CRITICAL POINTS TO REMEMBER!
- Propane (LP) gas has a distinctive odor. Learn to recognize these odors. (Reference Fuel Gas Odor and Odor Fading sections above.
- Even If you are not properly trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of propane (LP) gas and natural gas.
- If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system.
- A periodic sniff test around the heater or at the heater's joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT!
![]()
NEVER IGNITE AND / OR RUN THIS HEATER UNLESS THE SHELLS ARE FULLY EXTENDED AND LOCKED INTO POSITION. (Only for Models: MH80CVX, MH200CVX)
STEP 1: HEATER AS RECEIVED OUT OF BOX. BEFORE LIFTING OUTER SHELL PROTECT HANDS. NEVER GRASP BARE METAL WITHOUT HAND PROTECTION.
![]()
STEP 2: LIFT OUTER SHELL STRAIGHT UP. CARE MUST BE TAKEN TO PROTECT HANDS DURING LIFT.
![Mr Heater - MH25CVX - CRITICAL POINTS TO REMEMBER - Step 1 CRITICAL POINTS TO REMEMBER - Step 1]()
STEP 3: LIFT OUTER SHELL UNTIL ALL THREE CLIPS ENGAGE SLOTS IN LOWER SHELL. WHEN THIS HAPPENS, THE SCREW HOLES WILL LINE UP.
![Mr Heater - MH25CVX - CRITICAL POINTS TO REMEMBER - Step 2 CRITICAL POINTS TO REMEMBER - Step 2]()
STEP 4: LOCK THE CLIP INTO PLACE WITH 3 SCREWS AS SHOWN. THE HEATER MUST NOT BE OPERATED UNLESS THE OUTER SHELL IS PROPERLY EXTENDED AND FULLY LOCKED INTO PLACE.
![Mr Heater - MH25CVX - CRITICAL POINTS TO REMEMBER - Step 3 CRITICAL POINTS TO REMEMBER - Step 3]()
OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
- Extend the shell fully and lock into place as shown in the enclosed instructions sheet before lighting or operating the heater.
- Check the heater for possible shipping damage. If any is found, immediately notify the factory.
- Follow all of the Safety and Operating Precautions.
- Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinder's valve outlet and securely tighten with a wrench.
- Connect the hose to the heater.
- Securely tighten all gas connections.
- Open the cylinder's gas valve and check all gas connections with a soap and water solution. DO NOT USE A FLAME.
STARTING (200CVX)
![]()
WARNING: BEFORE LIGHTING PILOT, turn main burner valve (turn knob fully clockwise) to low/light position. - Fully open the valve on the propane cylinder and wait 15 seconds before Step 3.
- Depress red button on safety pilot valve (to the right of the variable valve knob) admitting gas to the pilot. Then push and release the ignition button (red button to the right of the variable valve knob) until the pilot lights.
- When the pilot lights, continue to hold the button depressed for 30 seconds, then release to light main burner.
- If pilot goes out, wait 5 minutes and repeat the lighting procedure.
- Turn main burner valve to regulate heat output.
STARTING (25CVX, 80CVX)
![]()
BEFORE LIGHTING PILOT, turn main burner valve (turn knob fully clockwise) to low/light position. - Fully open the valve on the propane cylinder and wait 15 seconds before Step 3.
- Push knob in and hold for 5 seconds, allowing gas to emit from burner orifice.
- Rotate the knob counterclockwise until the piezo igniter clicks. Continue to rotate and activate the igniter until the burner lights.
- Once the burner lights hold the knob in, on the low position for 30 seconds. Then release. The burner should stay lit. If it does not repeat steps 4&5 until the burner stays lit.
- Turn main burner valve to regulate heat output.
STOP (All UNITS)
- Securely close valve on the propane cylinder.
- Continue to operate heater until all fuel in the hose has burned.
- Turn main burner valve to lo/light position.
RESTART AFTER SAFETY SHUTDOWN
- Securely close valve at propane cylinder.
- Wait 5 minutes.
- Restart following "Start" procedure for your model.
MAINTENANCE AND STORAGE
- The heater should be inspected before each use, and at least annually by a qualified person.
- Before each use, check the soft "O" ring seat at the bullnose of the POL fitting. If the "O" ring is cut, scuffed, or otherwise damaged, replace it with part number F273786.
- Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.
- When the heater is to be stored indoors, the connection between the LP-gas supply cylinder(s) and the heater must be disconnected and the cylinder(s) removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1,Natural Gas and Propane Installation Code.
SERVICING
A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:
- The flame is contained within the heater.
- The flame is essentially yellow with some blue at the base of the fame adjacent to the burner.
- There is no strong disagreeable odor, eye burning or other physical discomfort.
- There is no smoke or soot internal or external to the heater.
- There are no unplanned or unexplained shut downs of the heater.
The parts lists and exploded view show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater.
![]()
Match the color stripe on the hang tag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Do not use alternates. For this heater, the regulator must be set as shown in "specifications". If there is any uncertainty about the regulator setting, have it checked.
A heater which is not working right must be repaired, but only by a trained, experienced service person.
In-warranty products will be repaired with no charge for either parts or labor. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.
Out-of-warranty products will be repaired with a charge for parts and labor.
SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED
The charts below show the approximate size of the cylinder required for these heaters. To use the chart:
- Select the lowest air temperature expected (at the bottom of the chart).
- Move straight up to time of operation desired (left side of chart).
- Read the cylinder size required.
All heaters should have:
- full cylinders
- good air circulation
- no frost on cylinders
25CVX
![Mr Heater - MH25CVX - SIZE/CAPACITY OF PROPANE CYLINDERS - 25CVX SIZE/CAPACITY OF PROPANE CYLINDERS - 25CVX]()
80CVX
![Mr Heater - MH25CVX - SIZE/CAPACITY OF PROPANE CYLINDERS - 80CVX SIZE/CAPACITY OF PROPANE CYLINDERS - 80CVX]()
200CVX
![Mr Heater - MH25CVX - SIZE/CAPACITY OF PROPANE CYLINDERS - 200CVX SIZE/CAPACITY OF PROPANE CYLINDERS - 200CVX]()
![]()
Air Quality Hazard
- Do not use this heater for heating human living quarters.
- Use of direct-fired heaters in the construction environment can result in exposure to levels of CO, CO2, and NO2 considered to be hazardous to health and potentially life threatening.
- Do not use in unventilated areas.
- Know the signs of CO and CO2 poisoning.
- Headaches, stinging eyes
- Dizziness, disorientation
- Difficulty breathing, feels of being suffocated
- Proper ventilation air exchange (OSHA 29 CFR 1926.57) to support combustion and maintain acceptable air quality shall be provided in accordance with OSHA 29 CFR Part 1926.154, ANSI A10.10 Safety Requirements for Temporary and Portable Space Heating Devices and Equipment used in the Construction Industry or the Natural Gas and Propane Installation Codes CSA B149.1.
- Periodically monitor levels of CO, CO2 and NO2 existing at the construction site – at the minimum at the start of the shift and after 4 hours.
- Provide ventilation air exchange, either natural or mechanical, as required to maintain acceptable indoor air quality.
| USA 8-Hr Time weighted average (OSHA 29 CFR 1926.55 App A) | Canada 8-hr time weighted average WorkSafe BC OHS Guidelines Part 5.1 and Ontario Workplaces Reg 833 |
CO | 50 ppm | 25 ppm |
CO2 | 5000 ppm | 5000 ppm |
NO2 | | 3 ppm (Reg 833) |
| USA – Ceiling Limit (Short Term Exposure Limit = 15 minutes) | Canada STEL (15 minutes Reg 833/1 hour WSBC) WorkSafe BC OHS Guidelines Part 5.1 and Ontario Workplaces Reg 833 |
CO | | 100 ppm |
CO2 | | 15000 ppm (WSBC) 30000 ppm (Reg 833) |
NO2 | 5 ppm | 1.0 ppm (WorkSafeBC) 5.0 ppm (Reg 833) |
- Ensure that the flow of combustion and ventilation air exchange cannot become obstructed.
- As the building 'tightens up' during the construction phases ventilation may need to be increased.
Installation of this appliance at altitudes above 2000 ft (610 m) shall be in accordance with local codes, or in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or National Standard of Canada, Natural Gas and Propane Installation Code, CSA B149.1
The heater has been shipped from the factory set up for operation on propane gas.
![]()
USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.
PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or direct from the factory
FOR INFORMATION REGARDING SERVICE
Please call Toll-Free 800-251-0001
www.mrheater.com
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in all communication.
PRODUCT REGISTRATION:
Please log in to http://www.egiregistration.com to register your product.
800-251-0001
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Mr Heater MH25CVX, MH80CVX, MH200CVX Manual
Need help?
Do you have a question about the MH25CVX and is the answer not in the manual?
Questions and answers