Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
innovair Manuals
Heat Pump
SLIM4 SAV Series
User manual
innovair SLIM4 SAV Series User Manual
Split system cooling only & heat pump
Hide thumbs
Also See for SLIM4 SAV Series
:
Installer's manual
(128 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Table Of Contents
45
page
of
45
Go
/
45
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Safety Precautions
Explanation of Symbols
Electrical Warnings
Information Servicing
Indoor Unit Parts and Major Functions
Operating Conditions
Care and Maintenance
Troubleshooting
Common Issues
Veuillez Lire Ce Manuel
Consignes de Sécurité
Explication des Symboles
Informations Sur L'entretien
Pièces de L'unité Intérieure et Principales Fonctions
Caractéristiques
Conseils en Matière D'économie D'énergie
Entretien et Maintenance
Dépannage
Problèmes Courants
Advertisement
Available languages
EN
FR
Available languages
ENGLISH, page 1
FRANÇAIS, page 23
Quick Links
Download this manual
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the SLIM4 SAV Series and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for innovair SLIM4 SAV Series
Air Handlers innovair INVERTER SLIM4 SAV Series Installer's Manual
Split system cooling only & heat pump, up to 19 seer2, heat pump 1.5-5 tons, r454b (128 pages)
Heat Pump innovair SLIM4 SAV18BDA Installer's Manual
Split system cooling only & heat pump up to 19 seer2 heat pump 1.5 - 5 tons r454b (72 pages)
Heat Pump innovair Dettson SLIM 24 HH EVO Owner's Manual
High efficiency heat pump system (54 pages)
Heat Pump innovair SLIM24 Installation And Owner's Manual
High efficiency heat pump system, split system heat pump & air conditioner up to 19 seer 1.5-5 tons r410a (56 pages)
Heat Pump innovair GOV36H2BA Installer's Manual
Split system cooling only & heat pump (54 pages)
Heat Pump innovair M4 Installation Manual
Multi-zone outdoor unit air conditioner (92 pages)
Heat Pump innovair MOM18H2BH3A Installation Manual
Multi zone ductless heat pump (44 pages)
Heat Pump innovair ELITE EIN13H2V32 Manual
Ductless splits, remote controller (4 pages)
Heat Pump innovair PEN36C2LS13 Installation Instructions Manual
Package heat pump & air conditioner (18 pages)
Summary of Contents for innovair SLIM4 SAV Series
Page 2
FOR UP TO DATE INFORMATION SUCH AS SPECIFICATIONS, CATALOGS, AND BULLETINS, PLEASE SCAN BELOW OR VISIT INNOVAIR.COM ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 3
These instructions may not cover every possible condition of use, so common sense and attention to safety is required when installing, operating and maintaining this product. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 4: Safety Precautions
If the air conditioner is used together with burners or other heating devices, ● thoroughly ventilate the room to avoid oxygen de ciency. In certain functional environments, such as kitchens, server rooms, etc., the use ● of specially designed air-conditioning units is highly recommended. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 5: Electrical Warnings
● those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition ● sources (for example: open ames, an operating gas appliance or an operating electric heater). ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 6
WARNING: The minimum room area or minimum room area of conditioned space is based on releasable charge and total system refrigerant charge. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 7
The test pressure after removal of pressure source shall be maintained for at least 1 h with no decrease of pressure indicated by the test gauge, with test gauge resolution not exceeding 5% of the test pressure. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 8: Information Servicing
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate re extinguishing equipment shall be available to hand. Have a dry power or CO2 re extinguisher adjacent to the charging area. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 9
10. Sealed electrical components shall be replaced if it's damage 11. Intrinsically safe components must be replaced if it's damage ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 10
The outlet for the vacuum pump shall not be close to any potential ignition sources, and ventilation shall be available. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 11
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 12
This symbol shows that a service personnel should be handling this equipment with reference to the installation manual. CAUTION This symbol shows that information is available such as CAUTION the operating manual or installation manual. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 13: Indoor Unit Parts And Major Functions
NOTICE Room relative humidity less than 80%. If the air conditioner operates in excess of this gure, the surface of the air conditioner may attract condensation. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 14
DO NOT place objects near the air inlet and outlet of the unit. Replace the air lter every 30 to 90 days depending on thickness and MERV. • Doors and windows Closing curtains during should be kept closed heating also helps keep the heat in ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 15: Care And Maintenance
Clean the unit using a damp, lint-free cloth and neutral detergent. Dry the • unit with a dry, lint-free cloth. NOTICE Inspect and clean or replace air lter each month or as required. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 16
Clean all lters Turn on FAN function until Check for damaged wires Check for leaks unit dries out completely Make sure nothing is blocking all air inlets and outlets Clean all lters ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 17: Troubleshooting
This noise is normal and is caused by the refrigerant gas stopping or noises changing direction. Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 18
Too many sources of heat in the room (people, computers, Reduce amount of heat sources electronics, etc.) Low refrigerant due to leak Check for leaks, re-seal if necessary and or long-term use ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 19
Cold air is entering through Make sure that all doors and performance doors and windows windows are closed during use Low refrigerant due to leak or Check for leaks, re-seal if necessary long-term use ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 20
The design and speci cations are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version. SAVU2410EA ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 22
FOR UP TO DATE INFORMATION SUCH AS SPECIFICATIONS, CATALOGS, AND BULLETINS, PLEASE SCAN BELOW OR VISIT INNOVAIR.COM ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 23: Veuillez Lire Ce Manuel
Il est donc nécessaire de faire preuve de bon sens et d'être attentif à la sécurité lors de l'installation, de l'utilisation et de l'entretien de ce produit. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 24: Consignes De Sécurité
• Ne pas faire fonctionner votre climatiseur dans une pièce humide telle qu'une salle de bains ou une buanderie. Une trop grande exposition à l'eau peut provoquer un court-circuit des composants électriques. • Ne pas exposer votre corps directement à l'air frais pendant une période prolongée. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 25
• Éteindre le climatiseur et le débrancher si vous ne l'utilisez pas pendant une longue période. • Éteindre et débrancher l'unité pendant les orages. • S'assurer que l'eau de condensation peut s'écouler librement de l'unité. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 26
: Modèle Unité d'intérieur Unité d'extérieur SOV18H2BA 18K(208/230V) SAV18BDA SHV18H2BA SOV24H2BA 24K(208/230V) SAV24BDA SHV24H2BA SOV30H2BA 30K(208/230V) SAV30BDA SHV30H2BA SOV36H2BA 36K(208/230V) SHV36H2BA SAV36BDA SHV36H2BB SOV48H2BA 48K(208/230V) SAV48BDA SHV48H2BA SOV60H2BA 60K(208/230V) SAV60BDA SHV60H2BA ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 27
égale à ces conditions d'arrêt ou de fonctionnement après l'installation. Les joints d'étanchéité détachables ne doivent PAS être utilisés du côté intérieur de l'unité (des joints d'étanchéité brasés ou soudés peuvent être utilisés). ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 28
à la valeur la plus faible ou de 500 microns et la valeur requise pour se conformer aux codes et normes nationaux et locaux, qui peuvent varier selon qu'il s'agit de bâtiments résidentiels, commerciaux ou industriels. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 29: Informations Sur L'entretien
Si un travail à chaud doit être effectué sur l'équipement de réfrigération ou sur toute pièce associée, un équipement d'extinction d'incendie approprié doit être disponible. Prévoir un extincteur à poudre ou à CO2 à proximité de la zone de chargement. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 30
• qu'il n'y a pas de composants électriques sous tension et de câblage exposés lors de la charge, de la récupération ou de la purge du système ; • qu'il y a une continuité de la mise à la terre. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 31
; et • ouvrir le circuit. La charge de réfrigérant doit être récupérée dans des cylindres de récupération de meilleure qualité si la ventilation n'est pas autorisée par les codes locaux et ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 32
Pomper le système de réfrigération, si possible. e) S'il n'est pas possible de faire le vide, installez un collecteur pour que le réfrigérant puisse être évacué des différentes parties du système. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 33
1. Transport d'équipements contenant des réfrigérants inflammables Conformité avec les réglementations en matière de transport 2. Marquage des équipements à l'aide de panneaux Conformité aux réglementations locales 3. Élimination des équipements utilisant des réfrigérants inflammables Conformité aux réglementations nationales ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 34
Ce symbole indique qu'un technicien doit manipuler cet équipement en suivant les instructions du manuel d'installation. PRUDENCE Ce symbole indique qu'il existe des informations PRUDENCE dans la notice d'utilisation ou le manuel d'installation. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 35: Pièces De L'unité Intérieure Et Principales Fonctions
AVIS Humidité ambiante relative inférieure à 80 %. Si le climatiseur fonctionne au-delà de ce chiffre, la surface du climatiseur peut attirer la condensation. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 36: Caractéristiques
• Remplacer le filtre à air tous les 30 à 90 jours en fonction de l'épaisseur et du MERV. Le fait de fermer les rideaux pendant le Les portes et les fenêtres devraient être chauffage permet également de conserver la maintenues fermées chaleur à l'intérieur ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 37: Entretien Et Maintenance
• Nettoyer l'unité à l'aide d'un chiffon humide non pelucheux et d'un détergent doux. Séchez l'appareil avec un chiffon sec et non pelucheux. AVIS Inspecter et nettoyer ou remplacer le filtre à air chaque mois ou selon les besoins. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 38
Vérifiez qu'il n'y a pas de fuites endommagés Nettoyer tous les filtres Activer la fonction FAN (VENTILATION) jusqu'à ce que l'appareil soit complètement sec Assurez-vous que rien n'obstrue les entrées et sorties d'air Nettoyer tous les filtres ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 39: Dépannage
L'unité intérieure émet des bruits Un grincement peut se produire après le fonctionnement de l'appareil en mode HEAT (CHAUFFAGE) en raison de l'expansion et de la contraction des pièces en plastique de l'unité. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 40
Si le problème persiste, communiquer avec un concessionnaire local. Leur fournir une description détaillée du dysfonctionnement de l'unité ainsi que le numéro de modèle. Dépannage En cas de problème, vérifiez les points suivants avant de contacter une entreprise de réparation. ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 41
Faible teneur en réfrigérant Vérifier s'il y a des fuites, refermer si en raison d'une fuite ou d'une nécessaire et remplir le réfrigérant utilisation prolongée ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 42
©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 43
©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
Page 44
Communiquer avec le comptoir de vente ou le fabricant pour plus de détails. Toute mise à jour du manuel sera téléchargée sur le site web du service, veuillez vérifier la dernière version. SAVU2410EA ©2024 Innovair Solutions. All Rights Reserved. www.innovair.com...
This manual is also suitable for:
Slim4 sav18bda
Slim4 sav24bda
Slim4 sav30bda
Slim4 sav36bda
Slim4 sav48bda
Slim4 sav60bda
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the SLIM4 SAV Series and is the answer not in the manual?
Questions and answers