  • Page 1 byko visc RT Lite Rotational Viscometer Operating Manual...
  • Page 2 byko visc RT Lite BYK-Gardner GmbH © Copyright 2024 BYK-Gardner GmbH All rights reserved 300 003 479 - 2411...
  • Page 3: Table Of Contents

    BYK-Gardner GmbH byko visc RT Lite Table of Contents ..........................6 Introduction .......................... 8 1.1 For Your Safety .......................... 9 1.2 Symbols .......................... 10 1.3 Disclaimer .......................... 10 1.4 Copyright .......................... 11 1.5 Declarations 1.5.1 Declaration of Conformity (EU) ................................11 1.5.2 Declaration of Conformity (UK) ................................
  • Page 4 byko visc RT Lite BYK-Gardner GmbH .......................... 30 5.4 Date / Time .......................... 30 5.5 Color-Scheme .......................... 31 5.6 Information .......................... 31 5.7 Factory Reset .......................... 32 5.8 Zero Check .......................... 33 5.9 Lock Settings ..........................34 Perform Measurements .......................... 35 6.1 Attach Spindle ..........................
  • Page 5 BYK-Gardner GmbH byko visc RT Lite 9.5.1 Instrument ................................57 9.5.2 General Data ................................58 9.5.3 Documentation ................................58 .......................... 59 9.6 Service Points 300 003 479 - 2411...
  • Page 6: Introduction

    Introduction...
  • Page 7 Application and Technical Seminars · Repair and Certification Service BYK-Gardner is part of ALTANA AG and a direct subsidiary of BYK, a leading supplier of additives for coatings and plastics. Together, we offer complete and unique solutions for you, our customer.
  • Page 8: For Your Safety

    byko visc RT Lite BYK-Gardner GmbH For Your Safety CAUTION: Familiarization with safety instructions necessary Failure to read and understand the safety instructions threatens your health and can damage the instrument. Read the safety instructions before you use the instrument the first time.
  • Page 9: Symbols

    BYK-Gardner GmbH byko visc RT Lite Symbols The label on the instrument contains the following symbols. Do not dispose of this product together with your household trash. Please refer to the information of your local community or contact our dealers regarding the proper handling of end-of-live electric and electronic equipment.
  • Page 10: Disclaimer

    byko visc RT Lite BYK-Gardner GmbH Disclaimer Exclusion of Liability No liability other than as provided by law is assumed for direct or indirect damage sustained in association with the use of the instrument, the software or documentation. BYK-Gardner precludes all liability claims if the usage described in "Intended Use" is disregarded. Any other usage than described in "Intended Use"...
  • Page 11: Declarations

    BYK-Gardner GmbH byko visc RT Lite Declarations 1.5.1 Declaration of Conformity (EU) BYK-Gardner GmbH Lausitzer Strasse 8 D-82538 Geretsried declare, that the instrument byko visc RT Lite complies with the requirements of the following directives: · 2014/30/EU - Electromagnetic Compatibility (EMC) ·...
  • Page 12: System Description

    System Description...
  • Page 13: Intended Use

    BYK-Gardner GmbH byko visc RT Lite The byko visc RT Lite is a benchtop viscometer which is operated by the touch screen. The power button - used to switch on the instrument - is located on the rear of the instrument above the power connector.
  • Page 14: Measurement Principle

    byko visc RT Lite BYK-Gardner GmbH Measurement Principle The instrument uses a precise stepper motor drive to rotate a specially designed spindle at a specific RPM in a sample of liquid. A torque spring is connected between the spindle immersed in the sample and a sensor system to determine the amount of torque required to rotate the spindle through a sample.
  • Page 15: Feature Matrix

    BYK-Gardner GmbH byko visc RT Lite Feature Matrix The BYK-Gardner byko-visc RT product family offers a wide range of high quality benchtop viscometers. For every purpose the best instrument is available. The byko-visc RT product group offers the premium models. The byko-visc RT Lite product group offers the economic models. byko-visc RT byko-visc RT Lite Low viscosity...
  • Page 16: Getting Started

    Getting Started...
  • Page 17: Delivery Content

    BYK-Gardner GmbH byko visc RT Lite The entire system consists of instrument, power supply and a set of spindles. Delivery Content The items listed below are contained in the packaging: · Rotational viscometer instrument mounted to adjustable stand · 4 spindles for L spring models, 6 spindles for R and H spring models ·...
  • Page 18: Control Elements

    byko visc RT Lite BYK-Gardner GmbH Control Elements Control of the instrument is provided by following elements. 1 Touch-screen display 2 Adjustable stand: · Knob for vertical adjustment · Lock for horizontal adjustment Spindle attachment (protective removed) 4 Support rod for stand 5 Spindle protector (form depends on model) 6 Spindle...
  • Page 19: Instrument Set-Up

    BYK-Gardner GmbH byko visc RT Lite Instrument Set-up Perform following steps: 1. Place the viscometer in a suitable location. 2. Turn protective cap clockwise to access spindle attachment. 3. Attach the desired spindle. 4. Plug the power supply into a mains outlet and plug the output cable into the back of the viscometer head.
  • Page 20: Main Menu

    byko visc RT Lite BYK-Gardner GmbH 3.5.1 Main Menu In the main menu the following symbols are displayed. Viscosity Measurement Perform measurements using existing parameters, change parameters and save results in instrument memory. Browse Measurements View and manage measurement results saved in instrument memory. Measurement Settings Change measurement settings and / or instrument configuration.
  • Page 21: User Interface

    BYK-Gardner GmbH byko visc RT Lite 3.5.2 User Interface To control the system the following UI elements are available. Activated The current option or function is active. Tap to deactivate. Deactivated The current option or function is inactive. Tap to activate. Save Save your changes and go back to previous screen.
  • Page 22: Measurement Settings

    Measurement Settings...
  • Page 23: Spindle

    BYK-Gardner GmbH byko visc RT Lite Tap the settings icon in the main menu to manage settings that are often changed. Before starting with measurements these parameters may have to be controlled. For settings that are seldom changed see System Configuration Spindle Here the spindle currently mounted can be selected to announce it to the measurement system.
  • Page 24: Speed

    byko visc RT Lite BYK-Gardner GmbH Speed Select the required speed of the spindle from the list of given speeds. The values are given in Revolutions per Minute (RPM). Density Enter the target density value of the material to be measured. This option is available, if activated under System Configuration >...
  • Page 25: Time To Stop

    BYK-Gardner GmbH byko visc RT Lite Time to Stop Activate the option to go to the screen Time to Stop. Enter the measurement time here. Use the arrow buttons to enter Hours, Minutes and Seconds and save with the check mark. Time to Torque Activate the option to go to the screen Time to Torque.
  • Page 26: System Configuration

    System Configuration...
  • Page 27: Units

    BYK-Gardner GmbH byko visc RT Lite Tap the settings icon in the main menu and tap on Configuration to manage settings that are seldom changed. Before starting with measurements the configuration may have to be controlled. Units Select the units used for measurement. 300 003 479 - 2411...
  • Page 28: Density

    byko visc RT Lite BYK-Gardner GmbH For the Viscosity following units are supported: · Milli Pascal Second: mPa.s · Centipoise: cP For the temperature following units are supported: · Celsius: °C · Fahrenheit: °F Select the required unit and save with the check mark. NOTICE The configuration for Units will be used as default and can also be changed directly during measurements.
  • Page 29: Language

    BYK-Gardner GmbH byko visc RT Lite Language Select the language of the user interface here. Following languages are supported: · English: English · German: Deutsch · Spanish: Español · French: Français · Russian: Pycckuu · Japanese: · Chinese: Select the required language and save with the check mark. 300 003 479 - 2411...
  • Page 30: Date / Time

    byko visc RT Lite BYK-Gardner GmbH Date / Time Here you can enter date, time and the format. The Time is entered with Hour and Minute. The Date is entered with Day, Month and Year. For Date and Time the Format to be displayed can be selected. Color-Scheme If this option is activated the white background of the display turns to black.
  • Page 31: Information

    BYK-Gardner GmbH byko visc RT Lite Information Under this option the details about instrument, firmware version and serial number can be retrieved. In case you contact your local BYK-Gardner service center please have these data handy. Factory Reset This option can be used to reset instrument to the factory settings. Tap on Factory Reset and follow the instructions on the display to perform the reset.
  • Page 32: Zero Check

    byko visc RT Lite BYK-Gardner GmbH Zero Check A zero check should be run when the Calibration Check has not passed (see Addendum Perform following checks: 1. Make sure, that the unit is properly leveled. 2. In Configuration tap Zero Check to initiate the procedure. 3.
  • Page 33: Lock Settings

    BYK-Gardner GmbH byko visc RT Lite Lock Settings This option can be used to lock the current settings against unintentional changes. If this option is deactivated the settings can be changed again. 300 003 479 - 2411...
  • Page 34: Perform Measurements

    Perform Measurements...
  • Page 35: Attach Spindle

    BYK-Gardner GmbH byko visc RT Lite Tap the measurement icon in the main menu to access the measurement screen. For viscosity measurements perform following steps: · Attach Spindle · Measure Viscosity · Change Parameters · End Measurment Attach Spindle Perform following steps: 1.
  • Page 36: Measure Viscosity

    byko visc RT Lite BYK-Gardner GmbH The spindle attached has to be selected in Measurement Settings > Spindle - or directly in Measure Viscosity Measure Viscosity To measure viscosity a sample container is necessary (not part of delivery). We recommend a 600 mL low form glass beaker.
  • Page 37 BYK-Gardner GmbH byko visc RT Lite The measurement screen displays the following items. TTS / TTT Counter for Time to Stop or Time to Torque Viscosity Average of measurements - taken every spindle revolution, tap unit to change Maximum Maximum possible viscosity value, depending on current spindle and speed Speed Current spindle speed in rotations per minute (RPM), tap value to change Spindle...
  • Page 38: Change Parameters

    byko visc RT Lite BYK-Gardner GmbH Change Parameters During measurement following parameters can be changed directly: Units : Tap on the unit currently shown. Speed : Tap the speed in RPM currently shown. Spindle : Tap the spindle name currently shown. To change all other settings, stop the measurement and go back to the Measurement Settings End Measurement...
  • Page 39: Special Measurements

    Special Measurements...
  • Page 40: Density

    byko visc RT Lite BYK-Gardner GmbH The instrument supports various viscosity measurement modes: · Density · Time to Stop · Time to Torque · Temperature Density To use the Density feature perform following steps: 1. Go to System Configuration and activate the option Density. 2.
  • Page 41: Time To Stop

    BYK-Gardner GmbH byko visc RT Lite Time to Stop To use the Time to Stop feature perform following steps: 1. Go to Measurement Settings and tap on Time to Stop. 2. Enter the time duration the measurement should last. 3. Perform a measurement and check the remaining time. The measurement is stopped when the time has expired.
  • Page 42: Time To Torque

    byko visc RT Lite BYK-Gardner GmbH Time to Torque To use the Time to Torque feature perform following steps: 1. Go to Measurement Settings and tap on Time to Torque. 2. Enter the target torque at which the measurement should stop. 3.
  • Page 43: Temperature

    BYK-Gardner GmbH byko visc RT Lite Temperature The temperature probe PT100 is available as an accessory. To measure the temperature of your sample perform following steps: 1. Attach the temperature probe to the Viscometer Head 2. Fix the cable for the probe on the spindle protector. 3.
  • Page 44: Browse Measurements

    Browse Measurements...
  • Page 45: Rename Test Series

    BYK-Gardner GmbH byko visc RT Lite Using this function you can manage the measured data. Click on icon Browse. The final viscosity value for a measurement is displayed here. Following operations are supported: · Export to USB · Print to USB Rename Test Series You can rename existing test series.
  • Page 46: Export To Usb

    byko visc RT Lite BYK-Gardner GmbH NOTICE The default file name can be configured in Date / Time Export to USB Export to USB to see all viscosity values measured over time. Perform following steps: 1. Attach USB flash drive to the viscometer head. 2.
  • Page 47: Print To Usb

    BYK-Gardner GmbH byko visc RT Lite NOTICE The export format is Comma Separated Values (CSV). In MS Excel create an empty sheet and select Data > Get Data > From File > From Text/CSV to convert the data in your file.
  • Page 48: Delete Data

    byko visc RT Lite BYK-Gardner GmbH Delete Data Measurement data not required anymore can be deleted from instrument memory. Tap the test series to be deleted - to delete all test series at once tap on button Select All - and tap on button Delete.
  • Page 49: Appendix

    Appendix...
  • Page 50: Addendum

    byko visc RT Lite BYK-Gardner GmbH Addendum In order to get the best results possible, a number of factors have to be considered when taking measurements with the byko-visc RT. Firstly, there are instrument specific factors. These include the spindle geometry, accuracy and sample volume size. Secondly, there are fluid dependent factors.
  • Page 51 BYK-Gardner GmbH byko visc RT Lite We are aware, that using the spindle guard is sometimes not practical for customers. It is absolutely possible to remove it, and or use smaller sample sizes than 500 mL. The instrument will keep measuring accurate torque values. However, these will not translate into accurate viscosity readings, because the boundary conditions have changed.
  • Page 52: Spindle Geometries

    byko visc RT Lite BYK-Gardner GmbH 9.1.3 Spindle Geometries Viscometer readings are dependent on several different factors. Most substances are found to be non-Newtonian. These are dependent on the shear rate and spindle geometry conditions. These factors can be found in the following Tables 2-4. Non-Newtonian fluids change their viscosity values dependent on the shear rate.
  • Page 53 BYK-Gardner GmbH byko visc RT Lite Model Spindle Recommen Container Part Shear rate Diameter Length number constant [mm] [mm] Volume [sec-1/rpm] [mL] TR-10 11.0 4966 0.28 9.39 32.0 TR-11 13.5 4967 0.25 7.62 27.18 Table 4: Overview over the recommended container sizes and spindle geometries for byko-visc RT models using vane spindles Model Spindle...
  • Page 54: Firmware Update

    byko visc RT Lite BYK-Gardner GmbH Firmware Update To update the firmware of your instrument perform following steps: 1. Go to System Configuration and tap on Information. 2. Check the current firmware version. 3. Get the new firmware, it is a compressed file of type "byko_update_x.y.z.tar.gz". 4.
  • Page 55: Maintenance

    BYK-Gardner GmbH byko visc RT Lite Maintenance 9.3.1 Cleaning and Routine Maintenance Remove the spindle after use to clean. Severe damage to the instrument can occur if the spindle is cleaned while mounted to the viscometer. The stainless steel paddle spindle may be cleaned with solvents required for the material being measured and a non-abrasive cloth.
  • Page 56: Service And Repairs

    byko visc RT Lite BYK-Gardner GmbH 9.3.3 Service and Repairs Do not perform any repairs on the unit. The unit must be opened by BYK-Gardner authorized repair locations only. Repair as this will void the warranty and affect the safety protection. 9.3.4 Troubleshooting If problems occur, verify that power is being applied, first to the power supply then from the...
  • Page 57: Technical Data

    BYK-Gardner GmbH byko visc RT Lite Technical Data All technical data are subject to change without notice. 9.5.1 Instrument Catalog number (*) 8347 byko-visc RT Lite L, base (Low viscosity) 8348 byko-visc RT Lite R, base (Regular viscosity) 8349 byko-visc RT Lite H, base (High viscosity) 8350 byko-visc RT Lite L, standard (Low viscosity) 8351 byko-visc RT Lite R, standard (Regular viscosity) 8352 byko-visc RT Lite H, standard (High viscosity)
  • Page 58: General Data

    byko visc RT Lite BYK-Gardner GmbH 9.5.2 General Data Indoor use Usage Temperature range 10° C to 40° C (50° F to 104° F) for operation 0° C to 60° C (32° F to 140° F) for storage Relative humidity Up to 85% non-condensing at 35°...
  • Page 59: Service Points

    BYK-Gardner GmbH byko visc RT Lite Service Points List of global service centers with ISO / IEC 17025 accredited laboratories Headquarter Germany Service Point USA c/o BYK-Gardner GmbH c/o BYK-Gardner USA Lausitzer Strasse 8 9104 Guilford Road 82538 Geretsried / Germany Columbia, MD 21046 / USA North Latin America Service Point South Latin America...