TPHK_P Series Instruction Manual Immersible Pump Model : TPHK2T_P / TPHK4T_P To ensure safe and proper use, please read this instruction before operation. ISO 9001 Certified WALRUS PUMP CO., LTD.
EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.83-14, Dapiantou, Sanzhi Dist., New Taipei City 252, Taiwan Declare that the machinery described: Name: Water Pump Model: TPHK_P Series Conform to the following directive: 2006/42/EC—Machinery directive 2014/35/EU—Low voltage directive 2014/30/EU—EMC (Electromagnetic compatibility) directive...
TPHK_P Instruction Manual 3. Operating Limits B efo re ins tallin g you r n ew 1. Ambient temperature: Max. 40°C s y s t e m , p l e a s e s t u d y a l l 2.
r e g u l a t i o n s . N e v e r m a k e fan cover end. any connections unless the 6.2. All piping joints are completely tight. electricity supply has been Leakage in piping may cause the switched off.
7.6. The pump should not be used to transfer toxic or contaminated liquids. Please carefully follow all instructions in the manual as Walrus may refuse to accept the contaminated pump for servicing. 7.7. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
Page 6
10. Fault Finding Make sure to disconnect the power before attempting to diagnose any fault. Fault Cause a. No electricity supply b. Fuses are blown. 10.1. Motor does not start c. Motor overheating relay tripped. d. Defective magnetic contactors. e. Control circuit malfunction. a.