Advertisement

Quick Links

Owner and
Operational Manua
Model:
Serial Number:
Install Date:
Installed By:
Service Phone:
Sold By:
Please read this manual carefully before proceeding with installation. Your failure to
follow any of these instructions or operating parameters may lead to personal injury
or damage to the equipment and/or personal property. Do not use this water
treatment system with water that is microbiologically unsafe or of unknown quality,
without adequate disinfection before or after the system. This water treatment
system contains replaceable treatment components critical for effective
performance. It is the user's responsibility to periodically test the product water to
verify the system is performing satisfactorily. Failure to properly maintain this water
treatment system may cause a health risk.
Save this manual for future reference
l
Aqua Magic 2510 SXT
4.9.2024 SB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aqua Magic 2510 SXT and is the answer not in the manual?

Questions and answers

Summary of Contents for Frakco Aqua Magic 2510 SXT

  • Page 1 It is the user’s responsibility to periodically test the product water to verify the system is performing satisfactorily. Failure to properly maintain this water treatment system may cause a health risk. Save this manual for future reference Aqua Magic 2510 SXT 4.9.2024 SB...
  • Page 2: Table Of Contents

    Contents ....................................... 1 Installation ................................ 3 START-UP INSTRUCTIONS ..........................4 3200 Timer Setting Procedure ........................... 4 3210 Timer Setting Procedure ........................... 5 3200, 3210, 3220, 3230 Regeneration Cycle Setting Procedure ................. 6 Timer Setting Procedure ........................... 6 Parts and Assembly ............................7 3200 Time Clock Timer Assembly ........................
  • Page 3: Installation

    Installation Water Pressure A minimum of 20 pounds (1.4 bar) of water pressure is required for regeneration valve to operate effectively. Electrical Facilities An uninterrupted alternating current (A/C) supply is required. NOTE: Other voltages are available. Please make sure your voltage supply is compatible with your unit before installation.
  • Page 4: Start-Up Instructions

    START-UP INSTRUCTIONS The water softener should be installed with the inlet, outlet, and drain connections made in accordance with the manufacturer’s recommendations, and to meet applicable plumbing codes. Turn the manual regeneration knob slowly in a clockwise direction until the program micro switch lifts on top of the first set of pins.
  • Page 5: 3210 Timer Setting Procedure

    Reset the time of day and restore power to the unit. 3210 Timer Setting Procedure Typical Programming Procedure Calculate the gallon capacity of the system, subtract the necessary reserve requirement and set the gallons available opposite the small white dot on the program wheel gear (Figure 3). NOTE: Drawing shows 8,750 gallon setting.
  • Page 6: Timer Setting Procedure

    3200, 3210, 3220, 3230 Regeneration Cycle Setting Procedure How To Set The Regeneration Cycle Program The regeneration cycle program on your water conditioner has been factory preset, however, portions of the cycle or program may be lengthened or shortened in time to suit local conditions. 3200 Series Timers (Figure 4) To expose cycle program wheel, grasp timer in upper left-hand corner and pull, releasing snap retainer and swinging timer to the right.
  • Page 7: Parts And Assembly

    Parts and Assembly 3200 Time Clock Timer Assembly...
  • Page 8 3200 TIME CLOCK TIMER ASSEMBLY Item No. QTY Part No. Description ....1 ..13870 ....Housing, Timer, 3200 ....1 ..14265 ....Clip, Sping ....3 ..14087 ....Insulator ....1 ..10896 ....Switch, Micro ....1 ..15320 ....Switch, Micro, Timer ....2 ..
  • Page 9: 3210 Meter Delayed Timer Assembly

    3210 Meter Delayed Timer Assembly...
  • Page 10 Item No. Part No. Description 1 ....1 ..13870 ..... Housing, Timer, 3200 2 ....1 ..13802 ..... Gear, Cycle Actuator 3 ....1 ..40096-02 ....Dial 2 AM Regen Assy, Black 4 ....1 ..13886 ..... Knob, 3200 5 ....4 ..13296 ....Screw, Hex Wsh, 6-20 x 1/2 6 ....2 ..
  • Page 11: 3220 Meter Immediate Timer Assembly

    3220 Meter Immediate Timer Assembly...
  • Page 12 Item No. QTY Part No. Description ....1 ..13870 ....Housing, Timer ....1 ..15431 ....Gear, Cycle Actuator, System #5 ....1 ..13886 ....Knob, 3200 .....4 ..13296 ....Screw, Hex Wsh, 6-20 x 1/2 ....2 ..11999 ....Label, Button ....1 ..
  • Page 13: Powerhead Assembly (Environmental)

    Powerhead Assembly (Environmental)
  • Page 14 Item No. Part No. Description 18697-15 Backplate, Hinged 2 ....1 ..11838 ....Power Cord, 6-feet, North American, Flat ..19303-01 ..... Power Cord, 6-feet, Austrailian ..19885-01 ..... Power Cord, 6-feet, Japanese ..11545-01 ..... Power Cord, 6-feet, European 3 ....1 ..13547 ....Strain Relief, Cord 4 ....1 ..
  • Page 15: Manual Powerhead Assembly

    Manual Powerhead Assembly Item No. QTY Part No. Description ....1 ..12593 ....Backplate, Manual ....1 ..12592 ....Bracket, Lever Position ....1 ..12596 ....Screw, Spec Mach, 1/4 - 20 x 1/2 ....1 ..12707 ....Washer, Spring ....1 ..
  • Page 16: Control Valve Assembly

    Control Valve Assembly...
  • Page 17 Item No. Part No. Description ....1 ..19328..... valve Body, 2510 ....1 ..11385-01 ..... Housing, Flow Control, Plastic ....1 ..11183 ....O-ring, -017 ....1 ..12408....Washer, Flow, 7.0 GPM ....1 ..18312....Retainer, Drain ....1 ..19322....Adapter Base, 2510 ....1 ..
  • Page 18 Item No. Part No. Description ....1 ..60705-00 ..DLFC, Plastic Blank ..60705-06 ..DLFC, Plastic 0.60 gpm ..60705-08 ..DLFC, Plastic 0.80 gpm ..60705-10 ..DLFC, Plastic 1.0 gpm ..60705-12 ..DLFC, Plastic 1.2 gpm ..60705-13 ..DLFC, Plastic 1.3 gpm ..
  • Page 19: Meter Assembly

    Meter Assembly Item No. Part No. Description ....4 ..12473 ....Screw - Meter Cover Assembly, 10-24 x 5/8-inch ....1 ..15659 ....Meter Cover Assy. - Ext., Rt. Angle (Not Shown) ..15452 ..... Meter Cap Assy, 3/4-inch to 2-inch , Std, Rt Ang/90, Plastic Paddle ....1 ..
  • Page 20: 1600 Brine System Assembly

    1600 Brine System Assembly Item No. Part No. Description ....2 ..10332 ....Fitting, Insert, 3/8 ....1 ..12767 ....Screen, Brine ....1 ..10328 ....Fitting, Elbow, 90 Deg. 1/4-inch NPT x 3/8Tube ....3 ..10329 ....Fitting, Tube, 3/8 Nut, Brass ....3 ..
  • Page 21: 1650 Brine System

    1650 BRINE SYSTEM Item No. Part No. Description 1 ....1 ..10328 ....Elbow, 90 1/4 NPT x 3/8 ....3 ..10332....Insert, 3/8 ....1 ..10330....Sleeve, 3/8 Nut Brine ....1 ..10329....Tube Fitting, 3/8 Nut Brine ....1 ..16508-01 ..... Tube, Brine Valve, 2850/2900s ..12774 ....
  • Page 22: Bypass Valve Assembly (Plastic)

    Bypass Valve Assembly (Plastic) Item No. QTY Part No. Description 1 ....2 ..13305 ....O-ring, -119 2 ....2 ..13255 ....Clip, Mounting 3 ....2 ..13314 ....Screw, Slot Ind Hex, 8-18 x .60 4A ....1 ..18706 ....Yoke, 1-inch , NPT, Plastic ..
  • Page 23: Bypass Valve Assembly (Metal)

    Bypass Valve Assembly (Metal) Item No. Part No. Description ....1 ..40614 ....Bypass Body, 3/4-inch ..40634 ....Bypass Body, 1-inch , SS ....1 ..14105 ....Seal, Bypass, 560CD ....1 ..11972 ....Plug, Bypass ....1 ..11978 ....Side Cover ....1 ..
  • Page 24: Seal & Spacer Tools & Replacement

    Seal & Spacer Tools & Replacement NOTE: Photos shown are for reference only for replacing the seal and spacer. Actual valve may be different. Turn off water supply to valve. Next, cycle valve to backwash position, then to service. Now remove electrical plug from outlet. Remove control box cover.
  • Page 25: General Service Hints For Meter Control

    Figure 8 Alternately remove the remaining seals and spacers in accordance with steps No. 6 and 8. The last or end spacer does not have any holes for the pins of the spacer tool to engage, therefore if the end spacer does not come out on the first try, try again using the wire hook with the finger loop.
  • Page 26: Troubleshooting

    Troubleshooting Problem Cause Correction Water conditioner fails to Electrical service to unit has been Assure permanent electrical service (check fuse, regenerate. interrupted plug, pull chain, or switch) Timer is defective. Replace timer. Power failure. Reset time of day. Hard water. By-pass valve is open.
  • Page 27: Wiring

    Wiring...
  • Page 28: Water Treatment System Warranty

    FRAKCO, INC. will replace or repair the defective item. Replacement of a defective item will be at FRAKCO’S factory in Luverne, MN, and the purchaser must ship the defective item at its own expense to FRAKCO’S factory. Replacement items will be shipped by FRAKCO F.O.B. Luverne, Minnesota, with a shipping carton furnished.

Table of Contents