Please read this manual carefully before proceeding with installation. Your failure to
follow any of these instructions or operating parameters may lead to personal injury
or damage to the equipment and/or personal property. Do not use this water
treatment system with water that is microbiologically unsafe or of unknown quality,
without adequate disinfection before or after the system. This water treatment
system contains replaceable treatment components critical for effective
performance. It is the user's responsibility to periodically test the product water to
verify the system is performing satisfactorily. Failure to properly maintain this water
treatment system may cause a health risk.
Save this manual for future reference
l
Aqua Magic 9100 SXT
4.11.2024 SB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aqua Magic 9100 SXT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Frakco Aqua Magic 9100 SXT

  • Page 1 It is the user’s responsibility to periodically test the product water to verify the system is performing satisfactorily. Failure to properly maintain this water treatment system may cause a health risk. Save this manual for future reference Aqua Magic 9100 SXT 4.11.2024 SB...
  • Page 2: Table Of Contents

    Table of Contents EQUIPMENT CONFIGURATION ......................... 3 INSTALLATION & START-UP ..........................4 Meter Dome and Union Orientation ........................7 9000/9100/9500 (3200 SERIES) ELECTRO MECHANICAL TIMER ASSEMBLY ............... 7 POWER HEAD ASSEMBLY..........................9 9000 CONTROL VALVE ASSEMBLY ........................11 9100 CONTROL VALVE ASSEMBLY ........................14 9500 CONTROL VALVE ASSEMBLY ........................
  • Page 3: Installation & Start-Up

    INSTALLATION & START-UP Water Pressure A minimum of 25 pounds (1.7 bar) of water pressure is required for regeneration valve to operate effectively. Electrical Facilities A continuous 115 volt, 60 Hertz current supply is required. Make certain the current supply is always hot and cannot be turned off with another switch.
  • Page 4 INSTALLATION & STARTUP CONTINUED Figure 6 Setting the Regeneration Cycle Program The Regeneration cycle program on the water conditioner is 19210 Rev D preset at the factory. However, portions of the cycle or program time may be lengthened or shortened for local conditions or system design.
  • Page 5 INSTALLATION & STARTUP CONTINUED 4. Because the control valve regenerates with soft water from the other tank, subtract the water used for regeneration. Changing Length of Brine Tank Refill Time Take each regeneration cycle and calculate the water used. The second group of holes on the program wheel determines Example: Unit is set for a 16-inch diameter tank with 4 ft the length of time the water conditioner refills the brine tank resin and salted at 8 lbs.
  • Page 6: Meter Dome And Union Orientation

    INSTALLATION CONTINUED 9000/9100/9500 (3200 SERIES) ELECTRO MECHANICAL TIMER ASSEMBLY Meter Dome and Union Orientation Control valves outfitted with an electromechanical timer and stainless steel water meter include a special male x female threaded stainless steel union to insure proper installation and operation of the water meter.
  • Page 7 Item No. Part No. Description 9000/9100/9500 (3200 SERIES) ELECTRO 21 ....3 .. 14087 ..Insulator MECHANICAL TIMER ASSEMBLY CONTINUED 22 ....1 ..15314 .... Switch, Micro, Modified 23 ....1 ..15320 .... Switch, Micro, Timer Item No. Part No. Description 1 ....1 ..
  • Page 8: Power Head Assembly

    POWER HEAD ASSEMBLY...
  • Page 9 POWER HEAD ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description 17 ....2 ..10340 .... Washer, Lock #4, Zinc 1 ....2 ..18728 .... Nut, Tinnerman, U Type, 8-32 18 ....2 ..16433 .... Switch, Miniature 2 ....1 ..
  • Page 10: 9000 Control Valve Assembly

    9000 CONTROL VALVE ASSEMBLY 24 46 23 21 14861-01 VALVE BODY,9000,MACHINED W/O-RINGS(P/Ns 11710 & 12281) 37 24 BR61500-9000 Rev...
  • Page 11 9000 CONTROL VALVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description 33 ....1 ..19153 .... Washer, Flow, 0.6 GPM 1 ....1 ..14861....Valve Body, 9000 ..19152 ..Washer, Flow, 0.8 GPM 2 .....16 ..13242-02 ..Seal, 5600,9000, 9100 ..
  • Page 12 0.50 BLFC #3 INJ, 4.0 DLFC 9000 CONTROL VALVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description 53 ..... 60421 ..Seal & Spacer Kit, 9000/9100 ..60385-0382 ..Injector Drain, 9000, 9100, Lower 0.50 BLFC #3 INJ, 5.0 DLFC ..
  • Page 13: 9100 Control Valve Assembly

    9100 CONTROL VALVE ASSEMBLY 11 13 28 27 BR61500-9100 Rev E Item No. Part No. Description Item No. Part No. Description 17 ....2 ..13363.... Washer, Hague Drive 1 ....1 ..40688 ..... Valve Body Assy, 9100 18 ....1 ..14905.... Piston, 9000, 9100 Lower 2 .....16 ..
  • Page 14 9100 CONTROL VALVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description 26 ....1 ..10914-000 ..Throat, Injector, #000, 47 ....1 ..13361 .... Spacer, 4600, 9100 Brown 48 ....1 ..40538 .... Retainer, 32 mm, O-ring ..
  • Page 15 9100 CONTROL VALVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description 0.50 BLFC #2 INJ, 3.5 DLFC ..60022-50 ..BLFC, 0.50 GPM, 5000/5600/9000/9100 ..60385-0272 ..Injector Drain, 9000, 9100, 0.50 BLFC #2 INJ, 4.0 DLFC ..
  • Page 16: 9500 Control Valve Assembly

    9500 CONTROL VALVE ASSEMBLY OPTIONAL 1600 INJECTOR 32 25 BR61500-9500 Rev E Item No. Part No. Description Item No. Part No. Description 1 ....1 ..16919-01 ..Valve Body, 9500, Machining 16 ....1 ..14921 .... Link, Piston Rod 2 .....16 ..16101 .... Seal, 2850, 4500 17 ....2 ..
  • Page 17: Optional (1600) Injector Part Number

    9500 CONTROL VALVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description Not Shown ..14801-05C ..Nozzle, Injector, 5C, White ..60481-21 ..Injector Assy, 1600, #1, S.S..14801-06C ..Nozzle, Injector, 6C, Red Brass, HW 29 ....1 ..
  • Page 18 9500 CONTROL VALVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description ..60708-12..DLFC, 1 inch F x 3/4 inch F, ..60721-70 ..DLFC, 1 inch F x 1 inch F, NPT, 12.0 GPM NPTF, 7.0 GPM ..
  • Page 19: 1600 Brine Valve System (For 9500)

    1600 BRINE VALVE SYSTEM (FOR 9500) Item No. Part No. Description 1 ....1 ..16960 ... Tube, Brine Valve 1 ..16960 ..Tube, Brine Valve, HW 2 ....1 ..10329.... Fitting, Tube, 3/8 Nut, Brass ..18698 ..Nut, 3/8-inch Tube, W/ Sleeve, HW 3 ....1 ..
  • Page 20: 1700 Brine Valve System (For 9500)

    1700 BRINE VALVE SYSTEM (FOR 9500) Item No. Part No. Description Item No. Part No. Description 21 ..... 60039-10 ..Brine Valve Assy. 9500/1700 1 ....1 ..14792 .... Plug, End, Brine Valve 1.0 GPM 2 ....1 ..13201 ....Quad Ring, -020 ..
  • Page 21: 1710 Brine Valve System (For 9500)

    1710 BRINE VALVE SYSTEM (FOR 9500) Item No. Part No. Description Item No. Part No. Description 17 ....1 ....Washer, Flow (Specify GPM) 1 ....1 ..41202.... Brine Valve, 1700, Plastic, 18 ....3 ..15415 .... Fitting, Insert, 1/2-inch, Tube 2 ....1 ..
  • Page 22: 3/4-Inch Meter Assembly

    3/4-INCH METER ASSEMBLY Item No. Part No. Description 1 ....1 ..14613 .... Flow Straightener 2 ....4 ..12473 .... Screw, Hex Washer, 10-24 x 5/8 3 ....1 ..14038 .... Meter Cap Assy, STD, Plastic 4 ....1 ..13847 .... O-ring, -137, Std/560CD, Meter 5 ....1 ..
  • Page 23: 1- Inch Meter Assembly

    INCH METER ASSEMBLY...
  • Page 24 INCH METER ASSEMBLY Item No. Part No. Description Item No. Part No. Description ..60389-001NP..Meter Assy, 1-inch Dual Port, 1 ..... 4 ..12112 .... Screw, Hex Hd Mach 10-24 NPT, STD, BRS BDY, 560CD, x 1/2 PDL, W/CLPS 2 .....
  • Page 25: Inch Brass Meter Assembly

    /2 INCH BRASS METER ASSEMBLY Item No.QTY Part No. Description Item No. Part No. Description 12 ..... 60610-02 ..Meter Assy, 1-1/2 inch, NPT, 1 ....1 ..17569.... Body, Meter, 2850/9500 STD, Brass Paddlewheel 2 ....1 ..13882.... Post, Meter Impeller ..
  • Page 26: Inch Stainless Steel Meter Assembly

    /2 INCH STAINLESS STEEL METER ASSEMBLY IMPORTANT: For valves equipped with electromechanical timers and stainless steel meters, refer to the Meter Dome and Union Orientation section. Item No. Part No. Description Item No. Part No. Description 3 ....1 ..44024 .... Union, 1-1/2 inch, NPT 1 ....1 ..
  • Page 27: 9000 Second Tank Assembly

    9000 SECOND TANK ASSEMBLY Item No. Part No. Description Item No. Part No. Description 1 ....1 ..14864-01 ..Adapter, 9000, 2nd Tank, ..15823-12NP ... 9000 Tube Assy, 6-inch to Machd w/O-rings 12-inch Dia. Tank (Overall Length 9.75) 2 ....8 ..13305 ....O-ring, -119 ..
  • Page 28: 9100 Second Tank Assembly

    9100 SECOND TANK ASSEMBLY Item No. Part No. Description 1 ....4 ..40678 .... Ring, 9100, Yoke Retainer 2 ....4 ..13287 ....O-ring, -123 3 ....1 ..14865 .... Adapter Assy, 2nd Tank, 9100 4 ....1 ..19054 ....O-ring, -124 5 ....1 ..
  • Page 29: I9500 Second Tank Assembly

    9500 SECOND TANK ASSEMBLY Item No. Part No. Description 1 ....1 ..13577 .... O-ring, -226 2 ....1 ..16455 ....O-ring, -347 3 ....8 ..10231.... Screw, Slot Hex, 1/4 - 20 x 1/2 4 ....4 ..17224 ....O-ring, -224 5 ....1 ..
  • Page 30: 2300 Safety Brine Valve

    2300 SAFETY BRINE VALVE 60027 Rev D Item No. Part No. Description Item No. Part No. Description ..60002-34 ..Air Check, #500, 34 inches 1 ....1 ..60027-00 ..Safety Brine Valve, 2300, Long Less Elbow ..60002-36 ..Air Check, #500, 36 inches 2 ....1 ..
  • Page 31: 2310 Safety Brine Valve

    2310 SAFETY BRINE VALVE...
  • Page 32 2310 SAFETY BRINE VALVE Item No. Part No. Description Item No. Part No. Description 14 ....1 ..60002-10 ..Air Check, #500, American 1 ....1 ..19645 .... Body, Safety Brine Valve, Hydro 2310 ..60002-11.38 ..Air Check, #500, 11.38 inches 2 ....1 ..
  • Page 33: 2350 Safety Brine Valve

    2350 SAFETY BRINE VALVE Item No. Part No. Description 1 ....1 ..60038.... Safety Brine Valve, 2350 1A ....1 ..61024 ... Actuator Assy, 2350 Brine 2 ....1 ..60028-30 ..Float Assy, 2350, 30-inch Wht ....1 .. 60026-30SAN .Float Assy, 2350, 30-inch Hot Water 3 ....1 ..
  • Page 34: Bypass Valve Assembly (Metal)

    BYPASS VALVE ASSEMBLY (METAL) 60040SS Rev T 60041SS Rev U Item No. Part No. Description 1 ....1 ..40614 .... Bypass Body, 3/4-inch ..40634 ..Bypass Body, 1-inch, SS 2 ....1 ..14105 .... Seal, Bypass, 560CD 3 ....1 ..11972 .... Plug, Bypass 4 ....1 ..
  • Page 35: Bypass Valve Assembly (Plastic)

    BYPASS VALVE ASSEMBLY (PLASTIC) 60049 Rev G Item No. Part No. Description Item No. Part No. Description 1 ....2 ..13305 ... O-ring, -119 ..41026-02 ..Yoke, 1-inch, BSP, Cast, 2 ....2 ..13255 .... Clip, Mounting MACHD, SS 3 ....2 ..
  • Page 36: General Service Hints For Meter Control

    GENERAL SERVICE HINTS FOR METER CONTROL Problem: Softener delivers hard water Reason: Reserve capacity has been exceeded. Correction: Check salt dosage requirements and reset program wheel to provide additional reserve. Reason: Program wheel is not rotating with meter output. Correction: Pull cable out of meter cover and rotate manually. Program wheel must move without binding and clutch must give positive clicks when program wheel strikes regeneration stop.
  • Page 37: Troubleshooting

    TROUBLESHOOTING Problem Cause Correction Water conditioner fails to Electrical service to unit has been Assure permanent electrical service (check fuse, regenerate. interrupted plug, pull chain, or switch) Timer is defective. Replace timer. Power failure. Reset time of day. Hard water. By-pass valve is open.
  • Page 38: 9000 Control Dimensions

    9000 CONTROL DIMENSIONS...
  • Page 39: 9100 Control Dimensions

    9100 CONTROL DIMENSIONS 1/2" - 14 NPT DRAIN PORT - --------- 2.00 (50.80) 0.53 (13.54) 11.4 5.30 (288.58) ------------------- (135.12) 3/8" O.D. TUBE 0.34 5.30 (8.56) (135.12) 2.56 (65.02) 1.10 2-1/2" NPSM 0.85 (27.81) (21.46) 61500-9100LNE_REVA...
  • Page 40: 9500 Control Dimensions

    9500 CONTROL DIMENSIONS...
  • Page 41: Water Conditioner Flow Diagrams

    WATER CONDITIONER FLOW DIAGRAMS 3 Tanks Switching Position 1 In Service Position (Meter Initiated Regeneration) 4 Brine Draw Position 2 Backwash Position 5 Slow Rinse...
  • Page 42 WATER CONDITIONER FLOW DIAGRAMS CONTINUED 8 In Service Position, Tanks Switched 6 Brine Tank Fill Position 7 Rapid Rinse Position...
  • Page 43 9000/9500 WIRING DIGR...
  • Page 44 SERVICE ASSEMBLIES Water 60481-21 ..... Injector Assy, 1600, #1, SS, HW 180° Brine Line Flow Controls (9000/9100): 60481-21 ..... Injector Assy, 1600, #2, SS, HW 180° 60022-12 ..... BLFC, .125 GPM, 5000/5600/9000/9100 60481-21 ..... Injector Assy, 1600, #3, SS, HW 180° 60022-25 .....
  • Page 45 60611-02NP ....Meter, 2850/9500, 1-inch Sleeve, NP Tube 1-1/2 inch Ext Meter 15823-14NP ....Yoke Assy, 14-inch Tank, NP 10-1/2 inch 17790 ......Sleeve, Meter, 1-1/2 inch x 1-inch Tube (NOTE: 15823-16 ..... Yoke Assy, 16-inch Tank, 12-1/2 inch when reducing a 1-1/2 inch meter to a Tube 1-inch meter, the program wheel and 15823-16NP ....
  • Page 46: Water Treatment System Warranty

    FRAKCO, INC. will replace or repair the defective item. Replacement of a defective item will be at FRAKCO’S factory in Luverne, MN, and the purchaser must ship the defective item at its own expense to FRAKCO’S factory. Replacement items will be shipped by FRAKCO F.O.B.