Summary of Contents for Frakco Aqua Magic 9100 SXT
Page 1
It is the user’s responsibility to periodically test the product water to verify the system is performing satisfactorily. Failure to properly maintain this water treatment system may cause a health risk. Save this manual for future reference Aqua Magic 9100 SXT 4.11.2024 SB...
Table of Contents EQUIPMENT CONFIGURATION ......................... 3 INSTALLATION & START-UP ..........................4 Meter Dome and Union Orientation ........................7 9000/9100/9500 (3200 SERIES) ELECTRO MECHANICAL TIMER ASSEMBLY ............... 7 POWER HEAD ASSEMBLY..........................9 9000 CONTROL VALVE ASSEMBLY ........................11 9100 CONTROL VALVE ASSEMBLY ........................14 9500 CONTROL VALVE ASSEMBLY ........................
INSTALLATION & START-UP Water Pressure A minimum of 25 pounds (1.7 bar) of water pressure is required for regeneration valve to operate effectively. Electrical Facilities A continuous 115 volt, 60 Hertz current supply is required. Make certain the current supply is always hot and cannot be turned off with another switch.
Page 4
INSTALLATION & STARTUP CONTINUED Figure 6 Setting the Regeneration Cycle Program The Regeneration cycle program on the water conditioner is 19210 Rev D preset at the factory. However, portions of the cycle or program time may be lengthened or shortened for local conditions or system design.
Page 5
INSTALLATION & STARTUP CONTINUED 4. Because the control valve regenerates with soft water from the other tank, subtract the water used for regeneration. Changing Length of Brine Tank Refill Time Take each regeneration cycle and calculate the water used. The second group of holes on the program wheel determines Example: Unit is set for a 16-inch diameter tank with 4 ft the length of time the water conditioner refills the brine tank resin and salted at 8 lbs.
INSTALLATION CONTINUED 9000/9100/9500 (3200 SERIES) ELECTRO MECHANICAL TIMER ASSEMBLY Meter Dome and Union Orientation Control valves outfitted with an electromechanical timer and stainless steel water meter include a special male x female threaded stainless steel union to insure proper installation and operation of the water meter.
9500 CONTROL VALVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description Not Shown ..14801-05C ..Nozzle, Injector, 5C, White ..60481-21 ..Injector Assy, 1600, #1, S.S..14801-06C ..Nozzle, Injector, 6C, Red Brass, HW 29 ....1 ..
Page 18
9500 CONTROL VALVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description ..60708-12..DLFC, 1 inch F x 3/4 inch F, ..60721-70 ..DLFC, 1 inch F x 1 inch F, NPT, 12.0 GPM NPTF, 7.0 GPM ..
/2 INCH STAINLESS STEEL METER ASSEMBLY IMPORTANT: For valves equipped with electromechanical timers and stainless steel meters, refer to the Meter Dome and Union Orientation section. Item No. Part No. Description Item No. Part No. Description 3 ....1 ..44024 .... Union, 1-1/2 inch, NPT 1 ....1 ..
GENERAL SERVICE HINTS FOR METER CONTROL Problem: Softener delivers hard water Reason: Reserve capacity has been exceeded. Correction: Check salt dosage requirements and reset program wheel to provide additional reserve. Reason: Program wheel is not rotating with meter output. Correction: Pull cable out of meter cover and rotate manually. Program wheel must move without binding and clutch must give positive clicks when program wheel strikes regeneration stop.
TROUBLESHOOTING Problem Cause Correction Water conditioner fails to Electrical service to unit has been Assure permanent electrical service (check fuse, regenerate. interrupted plug, pull chain, or switch) Timer is defective. Replace timer. Power failure. Reset time of day. Hard water. By-pass valve is open.
WATER CONDITIONER FLOW DIAGRAMS 3 Tanks Switching Position 1 In Service Position (Meter Initiated Regeneration) 4 Brine Draw Position 2 Backwash Position 5 Slow Rinse...
Page 42
WATER CONDITIONER FLOW DIAGRAMS CONTINUED 8 In Service Position, Tanks Switched 6 Brine Tank Fill Position 7 Rapid Rinse Position...
Page 45
60611-02NP ....Meter, 2850/9500, 1-inch Sleeve, NP Tube 1-1/2 inch Ext Meter 15823-14NP ....Yoke Assy, 14-inch Tank, NP 10-1/2 inch 17790 ......Sleeve, Meter, 1-1/2 inch x 1-inch Tube (NOTE: 15823-16 ..... Yoke Assy, 16-inch Tank, 12-1/2 inch when reducing a 1-1/2 inch meter to a Tube 1-inch meter, the program wheel and 15823-16NP ....
FRAKCO, INC. will replace or repair the defective item. Replacement of a defective item will be at FRAKCO’S factory in Luverne, MN, and the purchaser must ship the defective item at its own expense to FRAKCO’S factory. Replacement items will be shipped by FRAKCO F.O.B.