Installation Manual Room Air Conditioner 1U09YAESRA 1U25YAMCRA 1U12MAESRA 1U35MAMCRA 1U18KAMFRA 1U50KAMCRA 1U24KAMFRA 1U71KAMCRA Please read this manual carefully before installation. This appliance is filled with R32. Keep this operation manual for future reference. 0011538558...
Page 2
Contents Warning ..........................1 Loading and Unloading/Transporting Management/Storage Requirements......2 Installation Instructions......................3 Relocation Procedures......................8 Maintenance Instructions......................9 Scrapping and Recovery......................12 Indoor/Outdoor Unit Installation Drawings................13 Safety Precautions ........................14 Read Before Installation ........
Page 3
Read the precautions in this This appliance is filled with manual carefully before R32. operating the unit. Keep this manual where the user can easily find it. WARNING: Seek assistance from your dealer or qualified personnel for the installation of your air conditioner. Attempting to install it yourself could lead to risks such as water leakage, electric shocks, fire, or explosion.
Page 4
CAUTION Avoid installing the air conditioner in areas prone to flammable gas leakage to prevent fire hazards. Ensure proper tightening of the flare nut using specified methods like a torque wrench to prevent cracking and refrigerant leakage. Take measures to prevent small animals from seeking shelter in the outdoor unit to avoid electrical malfunctions or fire risks.
Page 5
Installation Instructions Installation Precautions WARNING! Ensure that the room area where the R32 refrigerant air conditioner is installed meets the minimum requirement specified in the table below to prevent safety issues arising from refrigerant leakage. Once the horn mouth of connecting lines is fastened, it should not be reused to maintain air tightness.
Page 6
Installation Instructions Model CO2 Equivalent(t) Factory charge(kg) 1U25YAMCRA 0.58 0.40 1U35MAMCRA 0.73 0.50 1U50KAMCRA 1.10 0.75 1U71KAMCRA 1.30 0.88 The maximum refrigerant charge amount (M) Indoor unit Outdoor unit M kg AS25TBMCRA 1U25YAMFRA 0.78 AS35TBMCRA 1U35MAMCRA 0.93 AS50TDMCRA 1U50KAMCRA 1.30 AS71TDMCRA 1U71KAMCRA 1.50...
Page 7
Installation Instructions Safety Principles of Installation • 1. Ensure adequate ventilation by keeping doors and windows open during installation. 2. Prohibit open flames or heat sources exceeding 548 degrees Celsius in areas with flammable refrigerants. 3. Take anti-static measures such as wearing cotton clothing and gloves. 4.
Page 8
Installation Instructions Nitrogen charging for pressure maintaining and leak detection After connecting the evaporator of the indoor unit to the connector pipe and welding, follow these steps for pressure testing and leak detection: Charge nitrogen at a pressure above 4.0MPa into the evaporator and the connected piping using a nitrogen cylinder equipped with a reducing valve.
Page 9
Installation Instructions Dred Installation Instruction • Post-installation Inspection Items and Test Run Post-installation Inspection Items Items to Be Checked Consequence of Improper Installation Whether the installation is firm or not The unit may fall, vibrate or make a noise Whether the inspection on air leakage is The refrigerating capacity (heating capacity) may be insufficient completed...
Page 10
Relocation Procedures contractor supplied line , @月 , 1. Attach the DRED module to the board using the bayonet mechanism. 2. Strengthen the DRED module by fastening it with screws. 3. Connect the contractor supplied line and the ORM line. 4.
Page 11
Maintenance Instructions Maintenance Precautions Precautions • Maintenance involving welding of refrigeration pipelines or components within the R32 refrigerant air conditioner system should never be conducted at the user's site. • Tasks necessitating extensive disassembly and bending operations on the heat exchanger, such as replacing the outdoor unit chassis or fully disassembling the condenser, are strictly prohibited from being performed at the user's site.
Page 12
Maintenance Instructions • The ventilator and other electrical equipment at the maintenance site must be securely fixed with standardized pipe routing. Temporary wires and sockets are strictly prohibited at the maintenance site. Leak Detection Methods • The area where refrigerant leakage is checked must be free from potential ignition sources. Avoid using halogen probes or detectors with open flames for leak detection.
Page 13
Maintenance Instructions • Prior to any maintenance, perform leak detection and inspect the grounding reliability of the air conditioner to ensure no leaks and reliable grounding. • If the service of the air conditioner may exceed the allowable voltage and current limits, do not add any inductance or capacitance to the circuit.
Page 14
Scrapping and Recovery Note: Before scrapping, the technician shall be completely familiar with the equipment and all its features. The safe recovery of refrigerant is recommended. In case the refrigerant recovered needs to be reused, before which the sample of refrigerant and oil shall be analyzed. The power supply required shall be guaranteed before tests.
Page 15
Indoor/Outdoor Unit Installation Drawings The models adopt HFC free refrigerant R32 For installation of the indoor units, refer to the installation manual which was provided with the units. (The diagram shows a wall-mounted indoor unit.) Attention must be paid to the rising up of drain hose more than 15cm more than...
Page 16
Safety Precautions fire or explosion. Place the unit on a stable, level surface capable of withstanding its weight to prevent tipping over or falling, which could cause injury. Only use specified cables for wiring. - Securely connect each cable, ensuring they are not straining the terminals.
Page 17
Safety Precautions WARNING CAUTION Open the window and well ventilated the room In such a case, continuing to use the conditioner may damage it and pose risks of electrical shock or fire hazards.
Page 18
Safety Precautions Open the window and well ventilated the room explosion-proof fuse Install a explosion-proof breaker for current leakage at the power source to avoid the risk of the electric shock. Lack of a breaker for current leakage can pose risks of electric shock, fire, or explosion.
Page 22
4. Installation dimension(Unit:mm) AS09PBELRA B=Ø60mm B=Ø60mm AS25TBMCRA Floor fixing dimensions of the AS12PBELRA outdoor unit (Unit:mm) AS35TBMCRA 1U09YAESRA 1U25YAMCRA A=170mm C=130mm B=Ø60mm B=Ø60mm AS18PCMHRA Floor fixing dimensions of the AS50TDMCRA outdoor unit (Unit:mm) 1U12MAESRA 1U35MAMCRA A=212mm C=126mm B=Ø60mm...
Page 23
Installation Procedure Liquid pipe Ø6.35X0.8mm AS25TBMHRA/1U25YAMFRA AS35TBMHRA/1U35MAMFRA Gas pipe Ø9.52X0.8mm Ø6.35X0.8mm Liquid pipe AS50TCMHRA/1U50KAMFRA AS71TEMHRA/1U71KAMFRA Gas pipe Ø12.7X0.8mm Connection of pipes • When bending the pipe, avoid crushing it and prevent sharp bends to prevent breakage. • Use a radius of curvature of 40 mm or more when bending the pipe. •...
Page 24
Installation Procedure After completing the connection of the refrigerant pipe, an air tightness test should be conducted. • Use a nitrogen tank to pressurize according to the pipe connection mode as shown in the diagram. • Ensure that both the gas and liquid valves are closed. Before pressurizing to prevent nitrogen from entering the outdoor unit's circulation system, tighten the valve rods (both gas and liquid valve rods).
Page 25
Installation Procedure Remove the cap from the service port of the 3-way valve and the caps from the valve rod for both the 2-way and 3-way valves. Connect the service port to the low- pressure port on the gauge manifold using the appropriate hose projection. Connect the center projection of the charge hose from the gauge manifold to the vacuum pump.
Page 26
Installation Procedure 1U25YAMCRA 1U35MAMCRA 1U50KAMCRA 1U71KAMCRA ceramic type of AC 250V, T25A. local The explosion-proof breaker of the air conditioner should be all-pole switch. The distance between its two contacts should not be no A explosion-proof breaker must be installed. Power cable: Power cable: 3G2.5mm...
Page 27
Outdoor Unit Troubleshooting This unit will start immediately once electric power is supplied, without requiring an "ON" operation. Ensure to perform an "OFF" operation before disconnecting electric power for servicing. This unit has a function of automatic restart system after recovering power stoppage. Before conducting a test run for all heat pump models, ensure that the power source breaker (main switch) of the unit has been turned on for over 12 hours to energize the crankcase heater in advance of operation.
Page 28
Under our policy of continuous product improvement, these dimensions and specifications may change at any time. You should therefore check with your dealer or Haier’s Customer Care Centre to ensure this fl yer correctly describes the products currently available.