HOT TABLE WALL TYPE WITH BACKSPLASH,
 
CENTRAL AND PASS THROUGHT MODELS
 
WHM-107÷207 – CHM-107÷207 – CHM-107÷207-2SD
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Manual instructions
EN
Installation and Operation
 
Manual de instrucciones
ES
 
Uso y mantenimiento
 
OF THE SERIES
   
DOCUMENT CODE: STRUCTURE CODE
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WHM-106 and is the answer not in the manual?

Questions and answers

Summary of Contents for Edesa WHM-106

  • Page 1             HOT TABLE WALL TYPE WITH BACKSPLASH,   CENTRAL AND PASS THROUGHT MODELS   WHM-107÷207 – CHM-107÷207 – CHM-107÷207-2SD   OF THE SERIES                            ...
  • Page 2 edesaprofessional.com     MACHINES DRAWING. ELECTRICAL & DRAIN OR GAS SITUATIONS    ...
  • Page 3 edesaprofessional.com        ...
  • Page 4 edesaprofessional.com        ...
  • Page 5: Electric Diagram

    edesaprofessional.com     ELECTRIC DIAGRAM.          ...
  • Page 6 edesaprofessional.com            ...
  • Page 7 edesaprofessional.com     LEGEND FOR ELECTRIC DIAGRAM IN ALL LANGUAGES    Designation  Item  Quantity  Note  S1  Two positional switch  1    Electronic controller/    A1  1  Thermo regulator  K1  Contactor  1    1 – 1000‐1600    M1, M2  Circulating air blower  2 – 1700‐2000  R1  Tubular resistance 2000W  1    R2  Tubular resistance 1400W  1 – 1700‐2000    1 – 1000‐1600    B1, B2  Heating cassette  2 – 1700‐2000   ...
  • Page 8 edesaprofessional.com     FIGURE 2           ...
  • Page 9 edesaprofessional.com     FIGURE 3      FIGURE 4      viii  ...
  • Page 10 edesaprofessional.com     FIGURE 5  A    B       ...
  • Page 11 edesaprofessional.com     MANUAL INSTRUCTION INDEX English 1. Introduction ……….……………………………………...……………………..……….………......…..1. 1.1 Introduction to machine 1.2 Important safety information 1.3 Specifications Chart 2. Installation………………………………………………………………….……………………………………..….3 2.1 General information. 2.2 Transport, handling, unpacking, location. 2.3 Intended use and restrictions. 2.4 Manufacturer’s identification label description. 2.5 Installation and assembly.
  • Page 12: Introduction To Machine & Models

    ENGLISH     1. MACHINE INTRODUCTION 1.1 Introduction to machine 1.2 Important safety information 1.3 Specifications Chart 1.1 INTRODUCTION TO MACHINE & MODELS The electric hot table consist of three main areas: worktop, heating chamber and heating cassette  module “HC” (“Figure 1”). Depending on needs, worktop can be made with 100 mm rear backsplash, 40 mm  rear flat backsplash and as central worktop without backsplash. Heating chamber is covered by two sliding  doors. In pass through models door are installed also instead of back wall. Heating chamber is provide with  regulated shelf. Heating cassette module is placed on right side in models 1000 – 1600 mm length and on both  sides, on left and right in models 1700 – 2000 mm length.  1.2 IMPORTANT SAFETY INFORMATION Operation of the electric hot table may only be carried out by personnel who have received proper  training in operating or servicing catering equipment. At operating the electric hot table observe the following  safety rules:  to avoid burns be careful at moving ware, do not spill water and other liquids on the hot  tubular heaters – the tubular heaters temperature is around 480°C;  before cleansing establish the hot table switch “PS” (“Figure 1”) to position “0” and disconnect  the power plug;  if fault is detected switch OFF the hot table and call an electrician; ...
  • Page 13: Specification Chart

    ENGLISH     1.3 SPECIFICATION CHART   WHM; CHM; CHM‐2SD  Description  106‐166; 107‐167  176‐206; 177‐207  1  Rated power consumption  W  2050  3500  2  Rated voltage  V  230  3  Current  ‐  jedna faza, prąd przemienny, przewód neutralny  4  Current frequency  Hz  50  Rated power consumption of the right  5  W  2000 + 50  heating cassette  Rated power consumption of the left  6  W  1400 + 50  heating cassette  7  Quantity of heating cassettes  pcs.
  • Page 14: Installation

    ENGLISH     Overall  1000  1100  1200  1300  1400  1500  1600  1700  1800  1900  2000  dimensions   x 700  x 700  x 700  x 700  x 700  x 700  x 700  x 700  x 700  x 700  x 700  (width/ depth/  x 850  x 850  x 850  x 850  x 850  x 850  x 850  x 850  x 850  x 850  x 850  height)  Dimensions ...
  • Page 15: Transport, Handling, Unpacking, Location

    ENGLISH     After installation but before the electric hot table operation it is necessary to dry the hot table tubular  heaters “TS” during 1,5‐2 hours. Switch on the hot table main switch “PS” and set the temperature 50°C on the  electronic controller “EC” (“Figure 1”). After drying check up current leakage. The leakage should be less than  1mA on 1kW of nominal power consumption. Check up grounding chains.    2.2 TRANSPORT, HANDLING, UNPACKING, LOCATION. For correct and safe lifting operations:  • use the type of equipment most suitable for characteristics and capacity (e.g. electric pallet truck or  lift truck);  • cover sharp edges;    Before lifting:  • send all operators to a safe position and prevent persons from entering the handling area;  • make sure the load is stable;  • make sure no material can fall during lifting. Manoeuvre vertically in order to avoid impacts;  • handle the machine, keeping it at minimum height from the ground.  2.3 INTENDED USE AND RESTRICTIONS. When preparing the electric hot table for operation, proceed as follows:  to check up integrity and reliability of the electric grounding;  to set by the electronic controller “EC” (“Figure 1”, “Figure 3”)  the necessary temperature  provided by requirements.  Upon work termination establish the power switch “PS” to position “0” – “OFF”.  Disconnect the electric hot table.    ATTENTION !!!  Before the electric device operation it is necessary to remove preservation from grates, lattices with guides,  hot table chamber and back part of a door by soap solution.       ...
  • Page 16: Manufacturer's Identification Label Description

    ENGLISH     2.4 MANUFACTURER’S IDENTIFICATION LABEL DESCRIPTION. Compulsory data in the label characteristics:  1. Producer logo.  2. Factory address.  3. Made in “Origin Country”.  4. Manufacturing year.  5. Serial number.  6. Model.  7. Voltage.  8. Frecuency.  9. Power consumption.  10. CE symbol.  11. Waste disposal symbol.  2.5 INSTALLATION AND ASSEMBLY. Install the electric hot table in the following order:  before the electric hot table installation on the provide place remove the protective film from  all metal surfaces; hot table should be placed in well aired premise if  there is a possibility,  under an air‐cleaning hood; hot table can be placed separately or together with other kitchen  devices;  install the electric hot table not closer than 100mm from a wall;  the electric hot table connection to the power supply should be done according to current  legislation and specifications. Connections to the power supply is made only by the authorized  specialist service taking into account marks on the tablet with inscription;  edesaprofessional.com...
  • Page 17 ENGLISH     installation and connection should be made so that on the established and connected electric  hot table there was no access to current‐carrying parts without application of tools;  ‐ fuses for constant wiring should be provided on current 25A;  to established the electric device on a corresponding place; to level the table by adjusting legs  “RL” (“Figure 2”) so that working surface took horizontal position; the height should be user‐ friendly;  to ground the electric hot table safely connecting ground wire to a ground clamp; the ground  wire should be in a power cord;  to insert connecting devices of the hot table electric circuits (screw and non‐screw clamps), at  slackening it is necessary to tighten or bend to normal contact pressure;  The power cord wire cross‐section should not be less than the ratings listed in table below.  Power cable designation  Device  (grade, number of wires and rated wire cross‐section)  1000 – 1600  PCG 3 x 1,5 mm 1700 – 2000  PCG 3 x 2,5 mm   2.6 CONNECTIONS (ELECTRIC, GAS, WATER) Hot table electric connection/ power cord “PC” (“Figure 1”) is located in the bottom, front side of right  heating cassette.  As a power connection use only the power cord wire cross‐section that is suggested for device.  When preparing the electric hot table for operation, proceed as follows:  to check up integrity and reliability of the electric grounding;  to set by the electronic controller “EC” the necessary temperature provided by requirements.  Upon work termination establish the power switch “PS” to Position “0” – “OFF”.  Disconnect the electric hot table.  ATTENTION !!!  Before the electric device operation it is necessary to remove preservation from grates, lattices with guides,  hot table chamber and back part of a door by soap solution.  edesaprofessional.com...
  • Page 18: Operation

    ENGLISH     3. OPERATION 3.1 General information. 3.2 Control panel description. 3.3 Machine settings and programs. 3.1 GENERAL INFORMATION. PREPARING MACHINE FOR USE  The control panel of the table is on the right side of the device. To start the unit set the main power  switch “PS” (“Figure 1”) in position “1” – “ON”. Before adjusting the temperature, set the shelf in a convenient  position. On the shelf bottom, on the left and right sides are the supporting elements “SE” ("Figure 4"), which  allow you to set the shelf on five different levels. In “Figure 4” step II is shown by the arrow direction to  remove supporting elements “SE”. After setting the shelve in the correct position and validate the exact  location of supporting elements “SE” you can set the temperature of the heating chamber of the device.  3.2 CONTROL PANEL DESCRIPTION. On the front, right side of hot table is located heating cassette “HC” with control panel (“Figure 1”,  “Figure 2”). The panel includes main power switch “PS” with control light (“Figure 1”). Below the switch is  placed electronic controller „EC” (“Figure 1”, “Figure 3”), which is used to set and control the operating  parameters of the device. If it is necessary to disassemble the heating cassette you must unscrew two screws,  one in bottom side of control panel (“Figure 2” step I) and second in upper side of control panel (“Figure 2”  step II). Heating cassette is free and you can pull it out (“Figure 2” step III).  3.3 MACHINE SETTINGS AND PROGRAMS. After setting the main switch in position "1" – “ON” should light the control light switch and controller ...
  • Page 19: Maintenance

    ENGLISH     If it is necessary to disassemble the worktop you must disassemble rear wall first by removing three  screws on the bottom of rear wall ” (“Figure 5 A” step I). Then you must remove four screws placed in the back  bottom side of worktop (“Figure 5 A” step II) . Pass through models don’t have back wall and worktop screws  are placed in back side of device in sliding door profile (“Figure 5 B” step II). Next lift up rear side of worktop an  push to the front ” (“Figure 5 A B” steps III and IV).  4. MAINTENANCE 4.1 General safety rules. 4.2 Machine cleaning and maintenance routine. 4.3 Machine disposal. 4.1 GENERAL SAFETY RULES. General safety requirements:  do not install the electric hot table closer than 1m from inflammable materials;  at the electric hot table installation establish a switching protective armature, protecting fire  factors: short circuit, overstrain, overload, spontaneous switching ON;  at primary electric oven installation should be used:  ‐ circuit‐braker B 16A;  ‐ current circuit‐braker 30mA;  the electric hot table connection should be carried out taking into account safe load on the  electric system;  do not use the electric hot table in fire‐dangerous and explosive zones.    ATTENTION !!! ...
  • Page 20: Machine Disposal

    ENGLISH       If they are not going to be used for a long while, cover the surfaces with a thin layer of vaseline, above  all inside the tub.    IMPORTANT !!!  It is not necessary to use water hoses to clean the appliance as they may damage its operating components.  “Before carrying out any cleaning or During maintenance, the cable and plug must maintenance operation, disconnect the be kept in a visible position by the operator appliance from the power supply by means of carrying out the work.
  • Page 21: Troubleshooting Chart

    ENGLISH     5. TROUBLESHOOTING CHART 5.1 Troubleshooting guide chart 5.1 TROUBLESHOOTING CHART   IMPORTANT !!!  The replacement of a functional component must be carried out by an AUTHORISED TECHNICIAN.    As a rule, whenever an operating component is being replaced, the electric current to the appliance  must be cut off with the general power switch.  All problems in the electric oven malfunction are resulted in table below and should be removed by  duly qualified technicians only.    PROBLEM  POSSIBLE CAUSE  SOLUTION  ‐ There is no power supply.  To supply voltage.  The hot table chamber doesn’t  ‐ Wires fastening on entry posts of  To fix wires on entry posts of the  heat up, switches control light  the block had loosened.  blocks.  doesn’t burn, electronic controller  ‐ Thermo regulators, thermo  To replace defective details.  display doesn’t work.  switches are defective.    ‐ Switches are defective.   ...
  • Page 22 ESPAÑOL     LEYENDA DE ESQUEMA ELÉCTRICO EN TODOS LOS IDIOMAS Artículo  Cantidad  Nota  Designación  S1  Interruptor de dos posiciones  1    Controlador electrónico /    A1  1  Termoregulador  K1  Contactor  1    1 – 1000‐1600    M1, M2  Soplador de aire circulante  2 – 1700‐2000  R1  Resistencia tubular 2000W  1    R2  Resistencia tubular 1400W  1 – 1700‐2000   ...
  • Page 23 ESPAÑOL     ÍNDICE MANUAL DE INSTRUCCIONES Español 1. Introducción ……….……………………………………...…………………..……….………......…..1. 1.1 Introducción a la máquina 1.2 Información de seguridad importante 1.3 Tabla de especificaciones Instalación ………………………………………………………………….……………………………………..….3 2.1 Información general Transporte, manipulación, desembalaje, ubicación Uso previsto y restricciones Descripción de etiqueta de identificación del fabricante 2.5 Instalación y montaje Conexiones (eléctrica, gas, agua) 3.
  • Page 24 ESPAÑOL     1. INTRODUCCIÓN A LA MÁQUINA 1.1 Introducción a la máquina 1.2 Información de seguridad importante Tabla de especificaciones INTRODUCCIÓN A LA MÁQUINA Y MODELOS La mesa caliente eléctrica consiste en tres áreas principales: la encimera, la cámara de calentamiento y el casete de calentamiento, módulo "HC"...
  • Page 25 ESPAÑOL     trabajar sin toma de tierra;  trabajar sin protección externa;  operar la mesa caliente eléctrica sin paleta.    TABLA DE ESPECIFICACIONES   WHM; CHM; CHM‐2SD  Descripción  106‐166; 107‐167  176‐206; 177‐207  1  W  2050  3500  Consumo de de potencia nominal  2  Tensión nominal  V  230 ...
  • Page 26: Instalación

    ESPAÑOL     CHM‐2SD  Todas 1000  1100  1200  1300  1400  1500  1600  1700  1800  1900  2000  dimensiones x 700  x 700  x 700  x 700  x 700  x 700  x 700  x 700  x 700  x 700  x 700  (anchura / profundidad x 850  x 850  x 850  x 850  x 850  x 850  x 850  x 850  x 850  x 850 ...
  • Page 27 ESPAÑOL     Designación de los cables de alimentación Dispositivo  (grado, número de hilos y sección transversal de cable)  1000 – 1600  PCG 3 x 1,5 mm 1700 – 2000  PCG 3 x 2,5 mm   El interruptor de alimentación "PS" ("Dibujo 1") debe proporcionar la desconexión segura de la potencia de todos los terminales en el equipo eléctrico de la mesa caliente ; se debería conectar directamente a los terminales de alimentación y la separación entre los contactos de los terminales no debe ser inferior a 3 mm.
  • Page 28: Instalación Y Montaje

    ESPAÑOL     2.4 LA ETIQUETA DE IDENTIFICACIÓN DE FABRICANTE DESCRIPCIÓN 2.5 INSTALACIÓN Y MONTAJE Instalar la mesa caliente eléctrica en el siguiente orden:  antes de la instalación de la mesa caliente eléctrica en el lugar adecuado, retirar la película  protectora de todas las superficies metálicas; la mesa caliente debe estar colocada en un local  bien ventilado, si existe la posibilidad, bajo una campana de limpieza de aire; la mesa caliente  se la puede colocar por separado o junto con otros dispositivos de la cocina;  instalar la mesa caliente eléctrica no más cerca de 100 mm de una pared;  la conexión de la mesa caliente eléctrica a la fuente de alimentación debe hacerse de acuerdo  con la legislación y las especificaciones actuales. Las conexiones a la fuente de alimentación se  hace sólo por el servicio técnico autorizado, teniendo en cuenta las marcas de la etiqueta  identificativa;  instalación y conexión deben hacerse de manera que en la mesa caliente eléctrica establecida  y conectada no tenga acceso a partes conductoras sin la aplicación de las herramientas;   ‐ Fusibles para el cableado permanente deben presentarse de 25A;  establecer para el dispositivo eléctrico en un lugar correspondiente; para nivelar la mesa  mediante el ajuste de las piernas "RL" ("Dibujo 2") de modo que la superficie de trabajo tome  posición horizontal bien nivelada; y a la altura fácil de usarla;  la mesa caliente eléctrica conectar a tierra de manera segura el cable de tierra a una terminal  de tierra; el cable de tierra debe estar en un cable de alimentación;  para insertar dispositivos de conexión de los circuitos eléctricos de la mesa caliente (fijaciones   de tornillo o sin tornillo), es necesario aflojar para apretar o doblar y dejar  contactos a la  presión  normal;  edesaprofessional.com...
  • Page 29 ESPAÑOL     La sección transversal de alambre del cable de alimentación no debe ser inferior a los valores indicados     en la tabla siguiente.  Designación de los cables de alimentación Dispositivo  (grado, número de hilos y sección metálica calificada)  1000 – 1600  PCG 3 x 1,5 mm 1700 – 2000  PCG 3 x 2,5 mm   2.6 CONEXIONES (ELÉCTRICA, GAS, AGUA) La conexión de la mesa caliente eléctrica / el cable de alimentación "PC" ("Dibujo 1") se encuentra en  la parte inferior, parte frontal derecha de casete de calentamiento .   Como  conexión de alimentación, utilice solamente la sección transversal del alambre del cable de  alimentación que se sugiere para el dispositivo.   En la preparación de la mesa caliente eléctrica para la operación, proceda lo siguiente:  comprobar la integridad y fiabilidad de la puesta a tierra eléctrica;  establecer por el controlador electrónico "CE" la temperatura necesaria proporcionada por  requisitos.  A la terminación de trabajo colocar el interruptor de encendido "PS" en la posición "0" ‐ "OFF".  Desconectar la mesa caliente eléctrica.  ATENCIÓN  ...
  • Page 30: Descripción Del Panel De Control

    ESPAÑOL     3.2 DESCRIPCIÓN DEL PANEL DE CONTROL En frente,  lado derecho de la mesa caliente se encuentra la casete de calentamiento "HC", con panel  de control ("Dibujo 1", "Dibujo 2"). El panel incluye interruptor principal de energía "PS" con luz de  control ("Dibujo 1"). A continuación se coloca el interruptor controlador electrónico "CE" ("Dibujo 1",  "Dibujo 3"), que se utiliza para establecer y controlar los parámetros de funcionamiento del  dispositivo. Si es necesario desmontar la casete de calentamiento deberá desenroscar los dos tornillos,  uno en el lado inferior del panel de control ("Dibujo 2" etapa I) y el otro en el lado superior del panel  de control ("Dibujo 2" etapa II). La casete de calentamiento está libre y se la puede tirar fuera ("Dibujo  2" etapa III). 3.3 AJUSTES Y PROGRAMAS DE LA MÁQUINA Después de ajustar el interruptor principal en la posición " 1" ‐ " ON" se deben encender: el interruptor  de control de la luz y la pantalla del controlador. Deben mostrar la temperatura en la cámara de calentamiento  de la mesa, al mismo tiempo, se pone del calentador de ventilador " FH " ("Dibujo 1 ") . Si la pantalla del  controlador muestra el mensaje "OFF" alternando con la temperatura leída por la sonda conjunta, significa  que el controlador está apagado, el calentador se apaga también. Para habilitar el controlador debe mantener  pulsado el botón "UP " ("Dibujo 3 ") por más de 3 segundos. La pantalla deja de parpadear y la temperatura se  muestra continuamente . Ahora usted puede ajustar la temperatura de calentamiento deseada de la tabla de  calentamiento. Para ello, mantenga pulsado el botón ("Dibujo 3 ") "SET" durante 1 segundo. Después de un  momento, la pantalla comenzará a parpadear la temperatura programada. Baje pulsando el botón "DOWN "  ("Dibujo 3 ") o aumente pulsando la flecha "UP " ("Dibujo 3 ") hasta que se alcance la temperatura deseada.  Confirme la selección pulsando el botón "SET" ("Dibujo 3 "). Se puede establecer la temperatura mínima de 30°  y la máxima de 80°C. Si la temperatura en la cámara de calentamiento de la mesa es más baja que la  temperatura del sistema,  la luz de la pantalla indicará el calentamiento. Se apaga después de llegar la mesa de  la cámara a la temperatura programada. Siempre que la temperatura dentro de la tabla baja unos pocos  grados, el indicador de calentamiento aparecerá  (calentador tubular "TH" ("Dibujo 1 ") se iniciará el  calentamiento) hasta que se alcanza la temperatura esperada. Antes de introducir la carga, primero debe  calentar la cámara de mesa. ...
  • Page 31: Mantenimiento

    ESPAÑOL     4. MANTENIMIENTO 4.1 Normas generales de seguridad 4.2 Rutina de limpieza y mantenimiento de la máquina 4.3 Eliminación de la máquina 4.1 NORMAS GENERALES DE SEGURIDAD Requisitos generales de seguridad:  no instalar la mesa caliente eléctrica a menos de 1m de materiales inflamables; ...
  • Page 32: Eliminación De La Máquina

    ESPAÑOL     IMPORTANTE   No es necesario el uso de mangueras de agua para limpiar el aparato, ya que pueden dañar sus componentes  operacionales.  "Antes de realizar cualquier operación de Durante el mantenimiento, el cable y el enchufe limpieza o operación de mantenimiento, deben mantenerse en un lugar visible por el desconecte el aparato de la fuente de operario que realice el trabajo.
  • Page 33 ESPAÑOL     5. TABLA DE RESOLUCIÓN DE PROBLEMAS 5.1 Carta de la guía de solución de problemas 5.1 TABLA DE RESOLUCIÓN DE PROBLEMAS   IMPORTANTE  El reemplazo de un componente funcional tiene que estar llevado a cabo por un TÉCNICO AUTORIZADO.  Como regla general, cada vez que se sustituye un componente operativo, la corriente eléctrica del aparato se  debe cortar con el interruptor general.  Todos los problemas en la mesa caliente, de mal funcionamiento eléctrico están indicados en la tabla de abajo  y deben solucionarse únicamente por técnicos debidamente cualificados.  PROBLEMA  CAUSA POSIBLE  SOLUCIÓN  ‐ No hay  alimentación eléctrica.   Suministrar la alimentación.   ‐ Los cables de sujeción en los  Fijar los cables en los terminales  y  La cámara de mesa caliente no se  terminales de entrada del bloque  entrada de los bloques.  ...
  • Page 34                                   EDESA PROFESSIONAL   Can Milans, 5 E-08110 MONTCADA I REIXAC   Barcelona - Spain edesaprofessional@edesaprofessional.com www.edesaprofessional.com SPECIALIST IN STATIC PREPARATION AND FOOD DISTRIBUTION...

Table of Contents