Download Print this page

DMP 1141INT Installation Manual

Wall button transmitter

Advertisement

Quick Links

1141INT WALL BUTTON TRANSMITTER
Installation Guide
Figure 1: 1141INT Wall Button Transmitter
GET STARTED
The 1141INT Wall Button is a one-
button wireless transmitter. The
transmitter may be used for a
variety of applications such as
arming, disarming, triggering an
output, activating a Z-Wave device,
or activating a panic of emergency
alarm.
The 1141INT features a water-
resistant button (when installed
with double-sided tape) with
a status LED. If activated in
programming, the LED provides
visual indication that a message
has been transmitted and received
by the panel. The 1141INT receives
power from two supplied 3.0 V
lithium batteries.
What is Included?
One 1141INT Wall Button
Transmitter
Two batteries (3.0 V lithium
CR2430)
Serial number label
Hardware Pack
1
PROGRAM THE PANEL
Prior to programming, record the transmitter serial number or place
the included pre-printed serial number on the wall button. The serial
number is required during programming. As needed, use the zone
name and number label to identify a specific transmitter.
After completing each of the following steps, press CMD to advance
to the next prompt.
For an XT30 International Control Panel, enter 665 (PRO) at
1.
the keypad to access the PROGRAMMER menu. For an XR
Series International Control Panel, enter 6653 (PROG).
2.
At ZONE INFORMATION, enter the wireless zone number.
At *UNUSED*, enter the zone name.
3.
4.
At ZONE TYPE, press any select key or area and select the
zone type.
5.
At NEXT ZN?, select NO.
When WIRELESS? displays, select YES.
6.
7.
At SERIAL#, enter the eight-digit device serial number.
8.
At SUPERVSN TIME, enter a supervision time. Default is 240.
9.
At LED OPER, select one of the following options:
• YES: The LED blinks when the button is pressed, then once
every second for five minutes to confirm a message was
sent.
• NO: The LED blinks once when the button is pressed to
confirm a message was sent.
When the supervision time is set to 0, the LED blinks once every
minute to confirm communication from the panel. When the
supervision time is set to 60 or 240, the LED only blinks when the
button is pressed.
10. At the NEXT ZN? prompt, select YES if you are finished
programming the zone. Select NO if you would like to access
additional programming options.
11. To save panel programming, go to STOP and press CMD.
Note: The wall button may be programmed to be supervised.
When a receiver is installed, powered up, or the panel is reset,
the supervision time for transmitters, including wall buttons,
is reset. If the receiver has been powered down for more than
one hour, wireless transmitters may take up to an additional
hour to send a supervision message unless a button is pressed.
This operation extends battery life. A missing message may
display on the keypad until the transmitter sends a supervision
message.

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1141INT and is the answer not in the manual?

Questions and answers

Summary of Contents for DMP 1141INT

  • Page 1 Series International Control Panel, enter 6653 (PROG). GET STARTED At ZONE INFORMATION, enter the wireless zone number. The 1141INT Wall Button is a one- At *UNUSED*, enter the zone name. button wireless transmitter. The transmitter may be used for a...
  • Page 2 Figure 4: 1141INT PCB Figure 3: Top Cover Interior Details SELECT A LOCATION The 1141INT provides a survey capability to allow one person to confirm transmitter communication with the receiver. With the cover removed, hold the transmitter in the desired location. Press the button to send data to the panel and determine if communication is confirmed or faulty.
  • Page 3 MOUNT THE TRANSMITTER When mounting the 1141INT, refer to Figure 5 for mounting hole locations. Refer to Figure 6 if mounting with tape. To mount the 1141INT with double-sided tape, complete the following steps: Install two 13 mm wide strips of double-sided tape in the indentions on the back of the housing base.
  • Page 4 I N T R U S I O N • F I R E • A C C E S S • N E T W O R K S manufactured in Springfield, MO 2500 North Partnership Boulevard using U.S. and global components. Springfield, Missouri 65803-8877 LT-1326NT 1.01 24433 417.831.9362 | DMP.com © 2024...