1106 SERIES WIRELESS
UNIVERSAL TRANSMITTERS
Installation Guide
Tab
Figure 1: 1106 Housing
DESCRIPTION
The 1106 Series Wireless Universal
Transmitters are wireless, two-input
transmitters typically used for door
and window applications. The 1106E
features 128-bit AES encryption.
The 1106 Series provides a cover
tamper, magnetic reed switch, and
an on-board terminal block to allow
for external contact wiring.
Both contacts, internal and external,
can be programmed to operate
at the same time. This allows two
independent zones to operate from
one 1106.
The 1106 Series also features
Disarm/Disable functionality. When
this option is set to YES, Zone
Tripped messages are disabled
when the system is disarmed to
allow for extended transmitter
battery life. Supervision, Tamper,
and Low Battery are the only
messages that are sent to the panel
when the system is disarmed.
Compatibility
All DMP XT Series and XR Series and
all 1100 Series Wireless Receivers.
To enable encryption on 1106E models,
Version 183 is required for XT and
XR Series panels and Version 300 is
required for Wireless Receivers.
What is Included?
•
One 1106 Wireless Universal
Transmitter
•
One magnet with standard and
commercial housing and base
•
One 3.0V lithium CR123A battery
•
Hardware pack
•
Double-sided tape
1
PROGRAM THE PANEL
Refer to the panel programming guide as needed.
1.
At a keypad, enter 6653 (PROG) to access the Programmer
Menu.
Note: Steps 2 and 3 are for the 1106E to enable encryption.
If using an 1106, proceed to step 4 to continue the
installation.
2.
(1106E only) Navigate to System Options. At the
1100 ENCRYPTION prompt, select ALL to only add
encrypted wireless devices to the system. Select BOTH to
allow both encyrpted and non-encrypted wireless devices
to be programmed.
3.
(1106E only) The default passphrase appears at the
ENTER PASSPHRASE prompt. Press CMD to keep the
default. Press any select key or area to change the
passphrase and enter an 8-character hexidecimal string
(0-9, A-F).
In ZONE INFORMATION, enter the wireless ZONE NO: and
4.
press CMD.
5.
Enter the ZONE NAME and press CMD.
Select the ZONE TYPE and press CMD.
6.
At the NEXT ZN? prompt, select NO.
7.
8.
Select YES when WIRELESS? displays.
9.
Enter the eight-digit SERIAL# and press CMD.
10. At CONTACT, select either INTERNAL or EXTERNAL.
Note: Use consecutive zone numbers if using both internal
and external contacts.
11. If EXTERNAL was chosen in Step 7, choose NO or YES at
the NORM OPEN prompt.
12. Enter the SUPRVSN TIME and press CMD.
13. At DISARM DISABLE, select NO or YES.
14. At the NEXT ZN? prompt, select YES to finish programming
or select NO for additional programming options.
2
INSTALL THE BATTERY
Use a 3.0V lithium battery, a DMP Model CR123 battery, or an
equivalent model from Sony or Murata. For listed installations, use
either an Energizer® 123 battery or a CR123A battery manufactured
by Panasonic or Tekcell. Keep in mind, when setting up a wireless
system, program zones and connect the wireless receiver before
installing the battery.
1.
Open the 1106 by inserting a 1/4" flat head screwdriver in
the tab. See Figure 1.
2.
Gently pull upwards on the screwdriver handle until the
housing completely opens.
3.
Observe polarity and place the battery in the holder and
press it into place.
Need help?