Galaxy 2-20 Quick-start Guide
NOTE: It is strongly recommended that any personnel
installing a Galaxy 2 Series panel undertake appropriate
training as supplied by Honeywell Security. This training
is supplied free of charge and can be arranged by
contacting Honeywell Security on:
Tel:
+44 (0) 1355 354 000
Email: sales@ademco.co.uk
Setup
In order to get the system up and running, mount the panel
and connect and address all peripherals as described
below, before finally powering the system.
Peripheral Wiring
The following peripherals can be connected to the panel:
Mk7 LCD Keypad/Keyprox x 4
RIO/PSU x 1
RF Portal x 2.
NOTE: The system must be wired in a daisy-chain
configuration. Spur and star configurations must
not be used. The recommended cable used to
connect the RS485 (AB) line is twisted pair
screened cable (Belden 8723 equivalent).
However, for cable runs of less than 100m in
normal environments, standard 4-core cable can
be used.
Panel
AUX+
AUX–
A
B
RS485 Peripheral Wiring
Peripheral Addressing
The address on most peripherals is set by either jumpers or
a rotary switch. These must be set before the system is
powered up. See the instructions with the peripheral for
details.
The following table identifies the available peripheral
addresses:
Peripheral
Mk7 Keypad/Keyprox
RIO
PSU
RF Portal
Peripheral Addresses
Peripheral
+
A
B
Address
0, 1, 2, 3
2
2
4, 5
A full technical installation manual will be given to each
installer at the training session. Additional manuals can be
purchased from your distributor.
Mains Supply Wiring
This product is not suitable for installation, maintenance or
connection by the user. A competent, qualified engineer,
with for example NSI approval, must carry out installation
and maintenance.
Warning: A means of isolation from the mains supply
must be provided within two metres of the
control panel. Where live and neutral
supplies can be identified, a fused spur with
a 3A fuse must be fitted on the live circuit.
Where live and neutral circuits cannot be
readily identified, 3A fuses must be fitted to
both circuits.
Connect the wires to the mains terminal block in the panel
as follows:
Blue (neutral) – connect to terminal N
Green/Yellow (earth) – connect to terminal E
Brown (live) – connect to terminal L
First Boot-up
After all the peripherals have been wired and addressed,
apply power to the system. The keypads will configure and
show the default banner display.
Galaxy 20
09:00
Default User Codes
Default User Code: 1234
Default Engineer Code: 112233
Menu Access Operation/Navigation
Only valid codes can access the Galaxy Series 2 menu
options. Type the code then press ent to access the menu.
Data entry is via the 0-9 function keys and the * and # on
the keypad.
The A> and <B keys are cursor or scroll keys and are used
to scroll through options in menus.
The ent key is used to enter a PIN code and to accept
screen information.
The esc key is used to cancel or exit from the current
operation.
NOTE: Users cannot view or access options for which
they are not authorised.
1
V1.0
SAT 01 JAN

Advertisement

loading
Need help?

Need help?

Do you have a question about the Galaxy 2-20 and is the answer not in the manual?

Questions and answers

Summary of Contents for Honeywell Galaxy 2-20

  • Page 1 Additional manuals can be installing a Galaxy 2 Series panel undertake appropriate purchased from your distributor. training as supplied by Honeywell Security. This training is supplied free of charge and can be arranged by contacting Honeywell Security on:...
  • Page 2 How to get in and out of Engineer Mode Zone Wiring Entry to Engineer Mode is authorised by a user in menu The default zone configuration is 1k double-balanced as option 48 = Level 3 Access. Following this, the shown below: engineer will have 5 minutes in which to enter his code.
  • Page 3 Communications Menu Summary All the functions of the panel are accessible via the menu. The top level of the menu is summarised below: Built-in Comms The Galaxy 2 Series has a built-in telephone dialler. The incoming telephone line should be wired to the ‘Line In A B’...
  • Page 4 Seller shall have no obligation under this Limited Warranty or otherwise if the Both Aux+ combined 500 mA max product is altered or improperly repaired or serviced by anyone other than Honeywell Trigger Header +12 V 100 mA max factory service.

This manual is also suitable for:

Galaxy 2 series