TABLE OF CONTENTS Tip: Click on any section below to jump directly there Safety Compressor Specifications Important Safety Instructions Troubleshooting Extended Control Operation - Service Installation Service Mode Unpacking Your Appliance Thermistor Electrical Warranty Cutout & Product Dimensions Installing Your Appliance Side-by-Side &...
Page 4
IMPORTANT SAFETY INSTRUCTIONS Important Safety Instructions Warnings and safety instructions appearing in this guide are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when installing, maintaining or operating this appliance. Recognize Safety Symbols, Words and Labels WARNING...
Page 5
UNPACKING YOUR APPLIANCE WARNING CAUTION If the appliance was shipped, handled or stored in other EXCESSIVE WEIGHT HAZARD than an upright position for any period of time, allow the Use two or more people to move product. appliance to sit upright for a period of at least 24 hours Failure to do so can result in personal injury.
Page 6
ELECTRICAL Electrical Connection A grounded 115 volt, 15 amp dedicated circuit is required. This product is factory equipped with a power supply cord that has a three-pronged, grounded plug. It must be Do not remove plugged into a mating grounding type receptacle in ground prong accordance with the National Electrical Code and applicable local codes and ordinances.
Page 8
CUTOUT & PRODUCT DIMENSIONS PRODUCT DATA ELECTRICAL PRODUCT REQUITEMENTS # WEIGHT 105 lbs 115V/60Hz/15A (47.6 kg) “H” “D” “F” “E” Glass Door 21 1/2” 3 1/2” (8.9 cm) (54.6 cm) Shown Minimum Minimum rough-in opening is required to be larger than the adjusted height of the cabinet.
Page 9
INSTALLING YOUR APPLIANCE Leveling Information Installation 1. Use a level to confirm if the 1. Plug in the power/electrical cord. unit is level. Level should be 2. Gently push the unit into position. Be careful not to placed along top edge and entangle the cord or water and drain lines, if applicable.
Page 10
SIDE-BY-SIDE & STACKING INSTALLATION Side-by-Side Installation Two units may be installed side-by-side. Cutout width for a side-by-side installation is the cutout dimension of a single unit times two. No trim kit is required. However, 1/4" (6 mm) of space needs to be maintained between the units to ensure unobstructed door swing.
Page 11
INSTALLING THE ANTI-TIP DEVICE Anti-Tip Bracket 1. Slide unit out so screws on top of unit are easily accessible. 2. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below). 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver.
Page 12
DOOR REVERSAL Hinge Cover Reversing the Door Hinge cover included with the literature bag is optional. Location of the unit may make it desirable to mount the door on the opposite side of the cabinet. To install hinge cover: The hinge hardware will be removed and reinstalled on the •...
Page 13
DOOR REVERSAL Remove Bottom Hinge Install Top Hinge and Door 1. Use alternate hinge supplied with unit and reinstall the 1. Remove bottom hinge from cabinet using a T-10 TORX screws. Do not tighten . screw driver to remove three screws. 2.
Page 14
USING YOUR ELECTRONIC CONTROL Control Function Guide Function Command Notes ON/OFF Press and release. Unit will immediately turn ON or OFF. Adjust Ice Density See “Ice” section The ° F / ° C symbol will flash briefly after 5 seconds. Interior Enable Sabbath Mode Press and hold for 5 seconds and release.
Page 15
• Water Treatment Options • TDS level of 200 ppm or higher and/or a hardness of 12-19 gpg can be treated by Marvel’s in-line water filter accessories available at marvelrefrigeration.com: • S41016343-ACCY — Standard • S41016345-ACCY — Filter head 3/8”...
Page 16
INSTALLING THE WATER SUPPLY Water Hookup Based upon the TDS measurement, see the below table to determine the correct filter required to protect the ice 1. Turn off water supply and disconnect electrical supply machine. to product prior to attempting installation. 2.
Page 17
2. Connect to your local plumbing per the local code. CAUTION 3. If necessary, insulate drain line to prevent condensation. If your Marvel unit did not come with a factory installed CAUTION drain pump you must use a gravity style drain connection.
Page 18
INSTALLING THE DRAIN PLUMBING NOTE The maximum lift for the P60 drain pump is 10 feet. This must be done as close to the rear of the unit as possible.
Page 19
CARE & CLEANING Cleaning CAUTION Exterior Cleaning Do not use any solvent-based or abrasive cleaners. These types of cleaners may transfer taste and/or odor to the Stainless steel can discolor when exposed to chlorine gas, interior products and damage or discolor the interior. pool chemicals, saltwater or cleaners with bleach.
Page 20
Vent Tube • SafeCLEAN Plus™ Cleaner Cleaning Tube 1-8oz. bottle included with unit. and Funnel Need more cleaner? Call Marvel Customer Service at 616.754.5601 Dispenser Tube CAUTION Use only SafeCLEAN Plus™ Cleaner. Use of any other Press and release cleaner may damage the finish of the evaporator and will a.
Page 21
CARE & CLEANING 7. 06 will appear in the display Cleaning Condenser a. Reinstall shield and close door. b. The machine will circulate water and perform a Interval - Every Six Months series of final rinses for approximately 15 minutes. c.
Page 22
STAINLESS STEEL MAINTENANCE Background NOTE Stainless steel does not stain, corrode, or rust as easily as ordinary steel, but it is not stain or corrosion proof. Stainless steels can discolor or corrode if not maintained Stainless steel products should never be installed, or stored properly.
Page 23
ENERGY SAVING TIPS The following suggestions will minimize the cost of operating your refrigeration appliance. 1. Do not install your appliance next to a hot appliance (cooker, dishwasher, etc.), heating air duct, or other heat sources. 2. Install product out of direct sunlight. 3.
Page 24
OBTAINING SERVICE If Service is Required: • If the product is within the first year warranty period please contact your dealer or call Marvel Customer Service at 616.754.5601 for directions on how to obtain warranty coverage in your area. •...
Page 25
• Compressor: The compressor makes a hum or pulsing- sound that may be heard when it operates. If you think your Marvel product is malfunctioning, read the • Evaporator: Refrigerant flowing through an evaporator- Control Operation section to clearly understand the may sound like boiling liquid.
Page 26
WIRE DIAGRAM White light Bin temp Low water sensor Open Door switch Condenser Fan Yellow Auger Blue Pump Resevoir Valve Purple 120 V Black/Yellow Dump Valve 11 22 Open Open Black N.C. White FUSE Pump...
Page 27
The part that caused the damage must be returned to Marvel in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
Page 28
Final billing - Remodel • 60 day submittal deadline from date of completed service Warranty parts will be shipped at no charge after Marvel confirms warranty status. Please provide the model, serial • Only one repair or unit per warranty claim number, part number and part description.
Page 29
Warranty parts will be shipped at no charge after Marvel confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
Page 30
R-600a is heavier than air, do not allow any leakage/migra- tion to low areas such as basements and stairs. Never use a torch on a fully charged refrigeration system. Never substitute Marvel OEM replacement parts or methods of construction. R-600a must be stored and transported in approved...
Page 31
R600A SPECIFICATIONS R-600A Specifications/Labeling WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians R-600a is colorless and odorless. permitted to service R-600a equipped products. R-600a is considered non-toxic, but is flammable when All tools and equipment must be approved for use with mixed with air.
Page 32
R600A SPECIFICATIONS Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed. atmosphere. When re-brazing, proper ventilation is required along with constant monitoring for the presence of R600a refrigerant.
Page 33
R600A SPECIFICATIONS The low side of the refrigeration system (evaporator, compressor and suction line) must be leak tested with the compressor off (equalized pressure). Recharging No air is ever to be allowed inside the refrigeration system (R-600a refrigerant or dry nitrogen only). Never use a torch on a fully charged refrigeration system.
Page 34
SYSTEM DIAGNOSIS GUIDE Refrigeration System Diagnosis Guide System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold Slightly warm Hot to warm Cool Cold...
Page 35
COMPRESSOR SPECIFICATIONS FMXA9C WARNING Refrigerant R600A Electrocution can cause death or serious injury. Burns Voltage 115 VAC from hot or cold surfaces can cause serious injury. Frequency 60 Hz Take precautions when servicing this unit. Start Winding 5 Ohm at 77°F Disconnect the power source.
Page 36
Evaporator: Refrigerant flowing through an evaporator Included in this section are some diagnostic tips; if may sound like boiling liquid. additional help is required, please contact Marvel at • Condenser Fan: Air moving through a condenser may 616.754.5601 for assistance.
Page 38
TROUBLESHOOTING EXTENDED Main Control CAUTION The main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose the board for any suspected failures before attempting Precautions must be taken while working with live to remove the board for replacement or service.
Page 39
CONTROL OPERATION-SERVICE UI Button Layout Control Function Guide Function Command Display/Options ON/OFF Press Unit will immediately release turn ON or OFF 1. Hidden Button Sabbath Mode See "Sabbath -Access Service Menu Mode" section -No LED directly above. All LEDs turn on with button 2.
Page 40
SERVICE MODE Service Mode Guide 1. THERMISTOR 1 — ZONE This shows the pure thermistor reading with no offsets 0. Exit taken into account. 1. Thermistor 1 temperature not including offsets. 2. THERMISTOR 2 — EVAPORATOR 2. Thermistor 2 temperature not including offsets. This shows the pure thermistor reading with no offsets 3.
Page 41
SERVICE MODE 15: CLEAR ERROR LOG To clear errors, press and hold (5 seconds) when CLR is flashing. 16: THERMISTOR - 1 DIFFERENTIAL This number should not be adjusted. 17. Does not apply to this model. 18. THIS NUMBER SHOULD NOT BE ADJUSTED 19.
Page 42
THERMISTOR Thermistors Evaporator Thermistor Thermistors are used for various temperature readings. If the evaporator thermistor fails, the unit will rely on a Thermistors provide reliable temperature readings using a preset defrost timer during defrost cycles. The unit will resistance which varies based on surrounding otherwise operate normally.
Page 43
For designated Marvel Professional product, Marvel offers a one year extension of the two year warranty coverage from the date of purchase, free of charge. To take advantage of this third year warranty, you must register your product with Marvel within 60 days from the date of purchase at marvelrefrigeration.com and provide proof of purchase.
Page 44
Marvel Refrigeration 1260 E. Van Deinse St. Greenville MI 48838 616.754.5601 All specifications and product designs subject to change without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, replacements or compensation for previously purchased products.