Page 1
C o m b u s tib le G a s M o n ito r In s tru c tio n M a n u a l...
Page 2
1.Introduction CONTENTS Combustible Gas Monitor adopts high-quality gas sensors,which displays safety and reliability with accurate measurement and stable performance. It has excellent sensitivity and repeatability,easy to ------------------------------------------------ (01) 1 Introduction use and maintain, and meets the requirements by safety monitoring -------------------------------------- (01) 2.Scope of application in industrial site for high reliability of the equipment.The shell is...
Page 3
:This operation may cause damage to the instrument. 6.Name of parts Please be careful. ①. Alligator clips on the back. Warning! If there is explode accident happening: ②.Transparent window for Cut off all the potential gas resource. alarm indicator. Keep the rescuing area ventilated and no potential ③.LCD display.
Page 4
The countdown second will be displayed on the left side of the 7.Features battery indicator. After the countdown is over, the instrument Color-screen display, user-friendly interface. will automatically shut down. Bilingual choices:Chinese/English. 4.There are five icon options in the main menu, namely, real-time Three alarm forms:sound/light/vibration .
Page 5
When the stored data is full, “FULL” will appear at the top of 2. When checking concentration, if the concentration value is screen.The bottom shows the selected page number and total lower than the low alarm value, the instrument will trigger low page number;which is page selection interface.
Page 6
3. In record selection interface shown in Figure 6, press “ ” back to the beginning; is an icon for starting, after sel- button to return to record selection state;Press“ ”/“ ” ecting it,the recorded data will automatically start review- button to check, delete, and choose which data to be deleted.
Page 7
System settings interface(Such as Figure11) 6. Figure 9 shows selected deletion interface. Pressing 1. There are six setting items under the interface: language, date “ ”/“ ” button and“ ” button to input the serial and time, auto storage, auto power off, backlight setting, and number to be deleted, select “OK”...
Page 8
signals are displayed in the lower right area ; the concentration c. Wait for the signal curve at the lower right of screen to be setting refers to setting the concentration value to be calibrated; stable; calibration AD value refers to the signal value output by the d.
Page 9
10.Specifications 11.Charging function description When the power is insufficient or the voltage cannot be turned on Gas detection due to undervoltage, please charge in time and charge it.During Measuring range 0~100%LEL the charging process, the alarm light will flash and the meter will Resolution no longer detect the gas concentration and display it dynamically.
Page 10
5. Cleaning of the instrument’s surface: 13.Product accessories list a. The window of the sensor must be kept clean. If it is dirty, the Thanks for your purchasing our product, please check the following measurement will be inaccurate. components after you unpacking the box. If there is any missing or b.