WINTACT WT8811 Instruction Manual

WINTACT WT8811 Instruction Manual

Compound gas monitor

Advertisement

MODEL: WT8811
Compound Gas Monitor
Instruction Manual
WT8811
Any queries,kindly contact us feel free.
Contact Email: service@wintact.net
Tel: +86 13530057923(Wechat&WhatsApp)
Skype: raymondzheng2014
Version:WT8811-EN-00
Standard:Q/HTY 010-2018
Q/HTY 011-2018
Q/HTY 012-2018
Q/HTY 007-2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WT8811 and is the answer not in the manual?

Questions and answers

Summary of Contents for WINTACT WT8811

  • Page 1 MODEL: WT8811 Compound Gas Monitor Instruction Manual WT8811 Any queries,kindly contact us feel free. Contact Email: service@wintact.net Tel: +86 13530057923(Wechat&WhatsApp) Skype: raymondzheng2014 Version:WT8811-EN-00 Standard:Q/HTY 010-2018 Q/HTY 011-2018 Q/HTY 012-2018 Q/HTY 007-2018...
  • Page 2: Table Of Contents

    Contents 1.Before use Check up 1.Before use Check up-------------------------------------------------- (01) Thanks for your purchasing our product, please check the following components after you unpacking the box. If there is any missing or Introduction----------------------------------------------- (02) wrong page manual,please contact the local dealer. Name of parts---------------------------------------------(03) Functions--------------------------------------------------(04) Specifications-------------------------------------------- (0 5)
  • Page 3: Introduction

    Introduction Name of parts Compound Gas Monitor adopts high-quality gas sensors,which displays safety and reliability with accurate measurement and stable performance. It has excellent sensitivity and repeatability, easy to use and maintain, and meets the requirements by safety monitoring in industrial site for high reliability of the equipment.
  • Page 4: Functions

    Functions Specifications Color-screen display, user-friendly interface. Compound Gas Monitor range Bilingual choices: Chinese/English. Range Measuring item Unit Resolution Measurement of four gas concentrations: Combustible gas (LEL), Combustible gas LEL %LEL 0~100 Oxygen (O ),Hydrogen sulfide (H S), Carbon monoxide (CO) Oxygen O %VOL 0~30...
  • Page 5: Operation Manual

    2.Operation manual 单 个 测 量 界 面 Single Measurement Interface Main Menu Interface 1. This interface only displays single measurement values; the left side 1. Long press on/off button (back shows the maximum minimum, button) for about 2 seconds. After and average value,where the powering on, the instrument enters average value is the value mea-...
  • Page 6: Multiple Measurement Interface

    1) Back button : back to main menu interface. and enter into record selection 2) Left/right button : Switch measurement items (oxygen, interface, as shown in Figure 5.2. carbonmonoxide, hydrogen sulfide, combustible gases). 3) Confirm button : No use. 单 个 测 量 界 面 Multiple Measurement Interface 1.
  • Page 7: Alarm Setting Interface

    4. The interface shown in Figure 5.4 is “OK” and press “ ”button. After that, the data within the range of reviewing interface of recorded data, serial number will be deleted. and the concentration value displa- 单 个 测 量 界 面 Alarm Setting Interface yed on the right side is the value of data point pointed out by red line;...
  • Page 8: Calibration Interface

    time (including calibration parameters) in the instrument can be restored calibration AD value by pressing “ ”button; the value between manual to factory state; calibration icon and ENTER icon is the real-time measured concentration value. 3.Calibration Interface (ONLY FOR PROFESSIONAL) Sensor Calibration Selection Interface Three Sensor Calibration Methods 1.
  • Page 9: Others

    4.Others d. Places of high temperature, high humidity or direct sunlight, including Charging function description environments of too high and low temperatures, high humidity, electromagnetic fields, and strong sunlight. When the power is insufficient or the voltage cannot be turned on 5.

Table of Contents

Save PDF