Table 1-6. System Messages (continued)
Message
SATA Port n hard disk not
found
Sector not found
Seek error
Seek operation failed
Shutdown failure
The amount of system
memory has changed.
The amount of tested
memory is below the
minimum system
configuration. System
halted!
Time-of-day clock stopped Faulty battery; faulty system board. See "Troubleshooting the System
24
About Your System
Causes
SATA hard drive not connected to
port n.
Faulty diskette or hard drive.
Shutdown test failure.
Faulty memory module.
Invalid memory configuration
Faulty memory module.
Corrective Actions
Ensure that the hard-drive cable is
properly connected. See "Hard Drives"
on page 53.
If a drive is not connected to port n,
check that the SATA port is disabled
in the System Setup program. See
"Using the System Setup Program" on
page 29.
Replace the diskette. If the problem
persists, see "Troubleshooting SATA
Hard Drives" on page 105 or
"Troubleshooting a SAS RAID
Controller" on page 107 for the
appropriate drive installed in your
system.
Ensure that all memory modules are
properly installed. See
"Troubleshooting System Memory" on
page 100. If the problem persists, see
"Getting Help" on page 121.
See "Troubleshooting System
Memory" on page 100. If the problem
persists, see "Getting Help" on
page 121.
See "General Memory Module
Installation Guidelines" on page 76.
See "Troubleshooting System
Memory" on page 100. If the problem
persists, see "Getting Help" on
page 121."
Battery" on page 98. If the problem
persists, see "Getting Help" on
page 121.