The grounding system must comply with the National Electrical Code and safety standards that apply in your
country. Always check with a qualified electrician if you are in doubt as to whether your outdoor installation is
properly grounded.
4.3 What is Lightning Protection?
All outdoor electronic equipment is susceptible to lightning damage. Proper grounding to national and local
codes is instrumental in providing human safety. Lightning Protection is used when a customer wants to
maximize the reliability of the electronic system by diverting the excess energy that can be induced on any
transmission lines (data, power) though a series of surge protection devices. The energy is dissipated through
heat and is also diverted to the ground.
4.4 Why is Additional Protection Recommended?
Lightning, even with the built-in protection, can still damage ZyAIR equipment. This can occur for any number
of reasons, such as an improperly grounded installation or if the amount of transient energy from nearby
lightning exceeds what the devices can handle.
If the ZyAIR unit fails due to damage from lightning, the link is out-of-service until the unit is replaced or
repaired. An external, reverting protection device can provide a higher level of protection, and greater
probability of surviving lightning strikes without damage to the ZyAIR equipment.
4.5 Mounting the ZyAIR
Use the included spanner with the mounting screws and nuts.
Note: Make sure the screws are securely fixed to the wall or mast and strong enough to hold the weight
of the ZyAIR with the connection cables.
4.5.1 ZyAIR Mast Mounting
You can mount the outdoor component of your ZyAIR directly to a pole with an outside diameter of 37.5mm ~
62.5mm (1.5" ~ 2.5").
To assemble the ZyAIR mast mounting components:
1 Insert the U-bolt into the mast-mounting bracket and attach the two nuts with one lock washer and one
split-lock washer.