Summary of Contents for Cheyenne SOL NOVA UNLIMITED II
Page 2
Minor to moderate injury CAUTION for proper and safe Property damage possible ATTENTION use. Keep them in a safe NOTE Advice / useful information place for later use. SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 02...
Page 3
Working on the battery ......28 2.5.2 Dimensions ..........14 4.3.1 Charging the battery ......28 2.5.3 Operating values ........14 4.3.2 Replacing the battery ......30 2.5.4 Charger data .......... 15 SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 03...
Page 4
7.2.1 Surface ........... 43 7.2.2 Clean the handle in an ultrasonic bath.. 43 7.2.3 Sterilising a contaminated handle in an autoclave ..........44 7.2.4 O-rings ........... 44 Repair ............. 44 SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 04...
Page 5
Figure 5-1: Increasing the needle protrusion . 36 Figure 5-2: Reducing the needle protrusion .. 36 Figure 5-3: Pressing one of the / buttons ............37 SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 05...
Page 6
SOL Nova 1.1 Intended use Unlimited II, see chapter “2.5.1 Operating conditions”, The SOL Nova Unlimited II is to be used in the • use any other inks other than those permitted by commercial sector. MT.DERM, The SOL Nova Unlimited II is a professional tattoo •...
Page 7
Persons with reduced physical, sensory, or mental Observe instructions abilities or persons with a lack of experience or knowledge must not use the SOL Nova Unlimited II. Use hand protection (protective gloves) There is a risk of suffocation from plastic bags and if swallowed.
Page 8
SOL Nova Unlimited II. keloids, or extreme tendency to develop keloids, solar keratosis, warts, and/or moles) in the skin Only work with the SOL Nova Unlimited II if you can area to be tattooed, perform the work reliably. D...
Page 9
Danger to life possible due to unsuitable tattooing inks. ▶ Only work with the SOL Nova Unlimited II if you are sufficiently trained. ▶ Only use dermatologically safe inks intended for tattooing. SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 9...
Page 10
6 days after tattooing, tip or the cap. • Skin irritation (e.g., itching or warming); this ▶ Switch off the SOL Nova Unlimited II to usually subsides in the first 12 to 72 hours after change a tattoo module.
Page 11
• Allergic reactions to components of the aseptic pigment ink. 1.11 Behaviour in an emergency Switch off the SOL Nova Unlimited II if there is a risk • injuries, • damage to the SOL Nova Unlimited II. Take immediate action and call the local emergency number in cases of accidents.
Page 12
3.5 | 4.5 Model GCB527* * Ink variant 10 - 49 The SOL Nova Unlimited II injects ink into the skin of a person to be tattooed using a high-frequency piercing needle. Figure 2-1: Scope of delivery The SOL Nova Unlimited II is generally operated via...
Page 13
▶ Protective tubes must be replaced for each new Follow the instructions for use! person to be tattooed. Satisfies UK legislation ▶ Dispose of the protective tube after each tattoo. Complies with the CE directives SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 13...
Page 14
The conditions at the place of use of SOL Nova Unlimited II must at least comply with these conditions. Any use under other conditions is at your own risk. We recommend contacting our customer service beforehand. SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 14...
Page 15
[mAh] 2000 Operating temperature [°C] 0 … 40 Capacity min. [mAh] 1940 [°F] 32 … 104 Typical capacity [mAh] 2040 Charging voltage [V] 4.2 Insulation class IP code IP20 SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 15...
Page 16
10%, citric acid ≤ 10%), • aliphatic hydrocarbons (e.g., pentane, hexane), • ethanol, • most inorganic salts and their aqueous solutions (e.g., sodium chloride, calcium chloride, magnesium sulphate). SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 16...
Page 17
The arrow button above the text is the button - increasing value, The arrow button below the text is the button - decreasing value. SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 17...
Page 18
5 s of inactivity. Select a menu item. Circle button ▶ The SOL Nova Unlimited II switches off after 5 min Return to the main screen Wait for 5 s of inactivity. Select “Back” in the main ▶...
Page 19
Gesture control when motor is on Use the gesture control to Circle button , change the penetration perform gesture frequency. C , perform gesture SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 19...
Page 20
2 Product description 2.8 Menus Menus Speed up/down hold O + gestur e Back Figure 2-5: Menu structure SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 20...
Page 21
• RUNTIME: Total period of use of your SOL Nova For more information on the motor modes, see Unlimited II (cannot be reset). chapter “5.5 Steady Mode and Responsive Mode”. SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 21...
Page 22
• The further down you hold the tip of the SOL Nova Unlimited II, the slower the penetration Set the display brightness: frequency will become. • MIN • If you hold the SOL Nova Unlimited II horizontally, • MAX a frequency of 90 Hz is set. • STANDARD 2.9.2 Twist •...
Page 23
SOL Nova Unlimited II. ▶ Remove the battery before transporting ▶ Do not switch the SOL Nova Unlimited II the SOL Nova Unlimited II and store it in on if it looks or sounds unusual.
Page 24
Height [mm] 75 longer periods of time. Observe the information on storage temperature and The SOL Nova Unlimited II is shipped in a cardboard humidity, see chapter “2.5.1 Operating conditions”. and plastic parcel. NOTE NOTE ▶...
Page 25
Remove the case from the box. NOTE ▶ Keep the packaging in case you need to repack the SOL Nova Unlimited II or want to store it for longer. Recycle the packaging material in an environmentally friendly manner.
Page 26
Condensation may cause damage to the electronics. ▶ Do not use the SOL Nova Unlimited II for at least 30 minutes to allow the SOL Nova Unlimited II to acclimatise if the SOL Nova Unlimited II has been exposed to large temperature fluctuations, for example during transport.
Page 27
D Nova Unlimited II. spray any liquids O NOT onto the SOL Nova Unlimited II and do not soak it in disinfectant. ATTENTION Wipe the SOL Nova Unlimited II and its components with a soft cloth moistened with Unauthorised disinfectants may cause damage.
Page 28
Incorrect power supply may cause property Contaminated accessories may lead to damage. infection. ▶ Only use the charger included in the scope of ▶ Touch the SOL Nova Unlimited II and its delivery or a charger recommended by MT.DERM accessories with clean, disinfected ONLY GmbH.
Page 29
This happens, for example, in case of a short circuit or if the battery is inserted the wrong way around. You have completed the charging process. Figure 4-5: Inserting the battery correctly SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 29...
Page 30
6. Push the operating unit into the drive unit until Figure 4-7: Removing the battery you hear it click into place. 3. Remove the battery from the control unit. You have changed the battery. SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 30...
Page 31
2. Unscrew the handle from the drive unit entirely. Figure 4-11: Pulling on the protective tube 3. Pull the end of the protective tube completely over the SOL Nova Unlimited II. SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 31...
Page 32
▶ N touch the used tattoo module by EVER the tip or the needle shaft. ▶ Always place the SOL Nova Unlimited II so that the tattoo module is not resting on ▶ Check that the needles are fully retracted top.
Page 33
3. Pull the old tattoo module out of the opening of the handle. Figure 4-15: Inserting the tattoo module 4. Insert the new tattoo module into the opening of the handle. SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 33...
Page 34
4 Prepare for use 4.6 Checking the equipment Checking the equipment 7. Switch on the SOL Nova Unlimited II and perform a listening test. Check the equipment of SOL Nova Unlimited II as 8. WARNING! Damage to the SOL Nova...
Page 35
Clean the skin of the person to be tattooed as follows before tattooing: Start and stop the SOL Nova Unlimited II as follows: 1. Use disposable gloves made of nitrile or latex. 1. Switch on the SOL Nova Unlimited II, C .
Page 36
5 Use 5.3 Needle protrusion Needle protrusion Set the needle protrusion as follows: 1. Switch on the SOL Nova Unlimited II, C . CAUTION 2. Turn the handle to adjust the needle protrusion. Punctures may reach the subcutaneous fatty tissue at excessive needle protrusion.
Page 37
5 Use 5.4 Penetration frequency Penetration frequency Set the penetration frequency as follows: 1. Switch on the SOL Nova Unlimited II, C . CAUTION The main screen will appear on the display and show the last set or used penetration frequency...
Page 38
Switch between the operating modes as follows: 1. Stop the SOL Nova Unlimited II. On the SOL Nova Unlimited II, you can choose 2. Call up the motor mode via fast Access by between the two operating modes “Steady Mode”...
Page 39
Steady Mode. 1. Dip the tip of the tattoo module into the desired The SOL Nova Unlimited II adapts to the load and ink for 2 to 3 seconds while the machine is energises the motor appropriately.
Page 40
1. Make sure that there is no danger to any persons clean the inside of the handle, the thread of the or objects. Switch off the SOL Nova Unlimited II drive unit, the grooves and the small O-ring (see immediately if any danger threatens.
Page 41
Use an original battery. LOAD TOO If the error persists: send in SOL EXCESS The battery may be faulty. HIGH! Nova Unlimited II. TEMPERATURE Replace the battery. BATTERY SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 41...
Page 42
Visual inspection, Daily battery). or engraving clean illegible on the labelling and / or components engravings as necessary In case of O-rings Visual inspection, wear replace O-rings as necessary SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 42...
Page 43
Penetrating liquids may damage the drive. thread of the drive unit. ▶ Never soak the SOL Nova Unlimited II in Due to the nature of the surface, ink fogging disinfectant. may occur on SOL Nova Unlimited II.
Page 44
7.3 Repair 7.2.3 Sterilising a contaminated handle in Repair an autoclave Sind your SOL Nova Unlimited II in if it is damaged. Sterilise the contaminated handle in the autoclave as follows: Contact our support (support@cheyennetattoo.com). 1. Disinfect all surfaces of the SOL Nova Unlimited For further contact details, see the end of these II, see chapter “4.2 Disinfecting the equipment”.
Page 45
▶ Observe the information on storage each fraction in an environmentally friendly manner. temperature and humidity, see chapter “2.5.1 Operating conditions”. ▶ Only store the SOL Nova Unlimited II in its case and original packaging. Disposal and recycling Ensure safe and proper disposal, in particular of parts or substances that are harmful to the environment.
Page 46
You have purchased a high-quality branded product • Damage caused by the ingress of liquids or dirt with the SOL Nova Unlimited II 2.5 / 3.5 / 4.5 from into the drive unit. Cheyenne. • Damage and consequential damage caused by The SOL Nova Unlimited II is guaranteed to be falling or dropping.
Page 47
9 Annex 9.2 EU/EC Declaration of Conformity EU/EC Declaration of Conformity Figure 9-1: Declaration of Conformity p. 1 SOL Nova Unlimited II 2.5 I 3.5 I 4.5 EN | 47...
Need help?
Do you have a question about the SOL NOVA UNLIMITED II and is the answer not in the manual?
Questions and answers