Page 1
Cryon-x User Manual Indications for safety use Indications for safe use This is a medical device. Please read this manual carefully and follow instructions at all times.
Page 2
The exterior and specifications of this device may be changed without notice for performance improvements. You can purchase accessories through Medi-Rent. Only Cryon-X accessories must be used with the device otherwise the warranty will be void.
Page 3
1. Introduction Introduction The Cryon-X Pro is an advanced therapy system offering both cold and hot compression therapy in a compact and efficient design. Unlike traditional devices, it combines cold/hot therapy with air compression, providing more effectiveness. Its innovative technology allows users to achieve their desired temperature and view real- time temperature readings, setting it apart from other devices on the market.
Page 4
2. Warnings Contraindications Patients under general anaesthesia, sedation, or with cognitive or communication impairments should not use the device unsupervised. Patients with the following conditions should avoid using the therapy system: • Venous or arterial occlusive disease • Cold allergies •...
Page 5
Precautions The following patients require physician supervision when using the device for cold and heat therapy: • Patients with insensitivity to pain in extremities • Patients with poor circulation • Patients with cognitive disabilities • Patients using medication affecting mental capacity •...
Page 6
Safety Warnings To ensure safe usage and minimise the risk of fire, electric shock, or injury, adhere to the following: • Refrain from inserting objects into the device's exterior case. • Avoid spilling any liquid on the device; promptly clean spills if they occur. •...
Page 7
3. Conditions and Compatibility Environmental Condition for Normal Working, Transport, and Storage • Normal working ambient temperature: 5~40°C • Normal working ambient humidity: 15%~90% • Store and transport ambient temperature: -25~70°C • Store and transport ambient humidity: 0~90% • Atmospheric pressure: 70~106kPa Electromagnetic Compatibility Warning: •...
Page 8
Guidance and manufacturer’s declaration – electromagnetic emission The device is designed to operate within the electromagnetic environment outlined below. Users must ensure that the device is used within this specified environment. Emission test Compliance Electromagnetic Environment – Guidance The device uses RF energy only for its internal function.
Page 9
OPERATING MANUAL Guidance and manufacturer’s declaration – electromagnetic immunity The device is designed to function within the specified electromagnetic environment. Users Guidance and manufacturer’s declaration – electromagnetic immunity must ensure its operation in such an environment. The device is designed to function within the specified electromagnetic environment. Users must ensure its operation in such an environment.
Page 10
NOTE 2 Please note that these guidelines may not be applicable in all circumstances. Electromagnetic propagation can be influenced by absorption and reflection from structures, objects, and individuals. TECHNICAL INFORMATION 6.4 kg (with battery) Model/type Cryon-X Pro Weight 5.1 kg (without battery) Powered by a 29.4V 5A Degree of protection against Power supply adapter or a 25.9V 10Ah...
Page 11
SYMBOL INTERPRETATION Symbols indicating essential information for proper usage must be utilized. The device and its labeling Symbol Interpretation feature the following symbols: Symbol Title ON/OFF button Refer to instructions for use Temperature setting Timer setting IP code of the device IP20 Disposal in accordance with Directive 2002/96/EC (WEEE) This way up...
Page 12
4. Product Description Product supplied 1. Therapy Device *1pc 2. AC Adapter * 1pc (Input: AC100-240V; Output: DC.29.4V--5A) 3. Wrap *1pc (The supplied wraps may vary based on your purchase needs) 4. Carry Case *1pc 5. Connecting Hose *1pc Device Specifications Power supply 29.4V 5A adapeter;...
Page 13
OPERATING INSTRUCTIONS knee wrap water tank Cryon-X Pro device Cryon-X Pro connecting hose heavy duty carry case power Drainage supply connector hose attachment How to Use the Device Connect Device to Power: Locate the power port at the back of the device and use the provided power cord to connect it to a wall outlet.
Page 14
OVERFILLING CAN LEAD TO SPILLAGE! Connect hosing to device only, The CRYON-X can run on battery or plugged into power. The device can making sure you hear a click be used whilst it is plugged in and charging. when connecting.
Page 15
Turn on device. The screen will display the setup screen. Press the green button to enter start. menu. The start screen shows the settings menu on “COLD and COMPRESSION” therapy mode. To adjust temperature or compression settings press the respective buttons on the screen and use the up/down arrows to set the desired value.
Page 16
6. How to Adjust the Device's Optional Parameters Seek guidance from your treating health practitioner on device settings. To adjust the various device settings please refer to the relevant section to change therapy option, adjust cold temperature, adjust heat temperature, adjust compression pressure and adjust timer setting.
Page 17
C. Adjust TIMER SETTING *Triple tap centre of screen for settings cog to appear Adjust “ON TIME” and “REST Tap the centre of the screen 3 TIME” using the up/down arrows. times to make the settings cog Press “SAVE”. visible. Select “TIMER SETTING”...
Page 18
B. Adjust HEAT Temperature Press “HEAT”. Adjust the temperature value The screen will return to the start using the up/down arrows. screen with the new setting. If “HEAT” is “OFF” and not able to be selected, you are in a COOL Change the temperature unit Press “START THERAPY”...
Page 19
7. Cleaning, Maintenance and Disposal Device cleaning NOTE: Prior to each use, inspect the device and adhere to the cleaning and disinfecting guidelines. Caution: Before and during cleaning or disinfecting, ensure the device is turned off and unplugged from the wall outlet. UNDER NO CIRCUMSTANCES SHOULD THE DEVICE BE IMMERSED IN ANY LIQUID.
Page 20
9. Troubleshooting Navigation from warning screen TROUBLESHOOTING The device will beep when a warning is triggered. Screen Display Sound Warnings Reasons The water is below Accept button - The Coolant the minimum Silence button - The Warning water level to alarm will cease and alarm will cease and work normally...
Page 21
Warnings If any of the proposed solutions do not work in the following pages, please contact Medi-Rent (AU) 1300 726 666 or (NZ) 0800 725 555. customer service on TROUBLESHOOTING Screen Display and Explanation Screen Display Sound Warnings Reasons Solutio TROUBLESHOOTING The water is below Please refill the water tank with di...
Page 22
Screen Display Sound Warnings Reasons Soluti temperature change is The water is below Please refill the water tank with d detected within 5 Coolant the minimum MAINTENANCE details. minutes, therapy Warning water level to cannot proceed. Screen Display and Explanation work normally Beeps will last 0.25s.
Page 23
seconds. If the warning still exists after reboot, contact customer service. Beeps will last 0.25s. issue persists, the alarm will rema Screen Display and Explanation Beeps will last 0.25s. warning persists after reboot, con High If the compression Pressure pressure is too Low Battery The battery Warning...
Page 24
8. Warranty Medi-Rent Pty Ltd – Cryon-X Limited Distributor Warranty Note: This warranty does not exclude or vary any of your rights under Australian Consumer Law This warranty covers the supplied equipment against defects arising through normal use of the equipment;...
Page 26
MEDI-RENT AUSTRALIA AU Ph: 1300 726 666 Head office: Unit 1/61 Beauchamp Rd Matraville NSW 2036 Unit 3/93 Riverside Ave Werribee VIC 3030 3/8 Emplacement Crescent Hamilton Hill WA 6163 NEW ZEALAND NZ Ph : 0800 725 555 9F Lady Ruby Drive East Tamaki 7201 info@medirent.com.au www.medirent.com.au...
Need help?
Do you have a question about the Cryon-x and is the answer not in the manual?