2101 field wizard installation and operation guide (76 pages)
Summary of Contents for Teledyne GV 300
Page 1
GV 300 Vision System Installation Manual 405-00039-00 GV 300 Installation Version 1.9; 2019-5-1...
Page 2
All copyrights in this manual, and the hardware and software described in it, are the exclusive property of Teledyne Imaging and its licensors. Claim of copyright does not imply waiver of Teledyne Imaging or its licensors other rights in the work. See the following Notice of Proprietary Rights.
Page 3
Certifications Declaration of Conformity Manufacturer Teledyne Digital Imaging US, Inc. 700 Technology Park Drive Billerica MA 01821 We declare that this product has been tested to comply with the EC Directive for a class A digital device in accordance with EN55022/CISPR22...
Page 4
If you need to return the GV 300 Vision System, you must contact the Teledyne Imaging representative who sold you the product. Do not return your product to Teledyne Digital Imaging US without prior authorization.
Page 5
Table Of Contents Introduction GV 300 Vision System ………………....... Product Support ………………....... Components ………………....... Installation Connecting the GV 300 ………………....... Front Connections ………………....... Rear Connections ………………....... GigE Cameras ………………....... Typical Configuration using ………………....... the PL-USB Typical Configuration using ………………....... the DCI-101...
Page 6
DIN mountable hardware. Product Support This manual will assist you with the installation and setup of your GV 300 product and the embedded inspection software. It describes what the product supports and how to connect the external interfaces.
Page 7
GV 300 Vision System Components GV 300 vision systems are shipped with the components listed below. Take a few moments to verify that everything has arrived in good condition. If your product has been visibly damaged during shipment or is missing parts, please contact your Teledyne Imaging representative immediately.
Page 8
Installation Connecting the GV 300 Vision System This section details the physical connections on the GV 300 vision system. The GV 300 provides connectors on both the front and rear plates. Front Connections ON/OFF button – recessed behind the front plate. Use blunt pointed object to turn power off.
Page 9
LAN left LED: Off = 10 Mbits/s; GREEN = 100 Mbits/s; ORANGE = 1000 Mbits/s LAN right LED: ON = port active; BLINK = port traffic NOTE: Camera Ethernet cables must be type Cat5e. Use A-CAB-GE-X. GV 300 Installation Version 1.9; 2019-5-1...
Page 10
Two cables are needed in the setup of each camera. The data cable (A-CAB-GE-X) connects the camera’s Ethernet port to one of the GV 300 camera ports. The I/O cable provides power to the camera and access to the camera’s I/O, including trigger. When using the PL-USB module (Genie camera breakout module), the standard GEVA cable should be used (A-CAB-GEVA-FX).
Page 11
3. Use A-CAB-GEVA-FX for I/O connections between Genie camera and PL-USB (other cables on page 4. Camera Input2 is the trigger, Output2 is the Strobe. Setup/Operator HMI (iNspect Express shown) 5. Wiring diagrams appear in the PL-USB Installation Manual. GV 300 Installation Version 1.9; 2019-5-1...
Page 12
2. Use A-CAB-GE-X for camera Ethernet connections 3. Use A-CAB-GEVA-FX for I/O connections between Genie camera and DCI-101. (other cables on page 7). 4. Camera Input1 is the trigger. 5. Wiring diagrams appear in the DCI-101 Quick Start Guide. GV 300 Installation Version 1.9; 2019-5-1...
Page 13
These applications offer a suite of vision capabilities that satisfy a diverse range of automated inspection needs. The following shows how to configure the GV 300 to work with either interface. Refer to the respective software user manual for more information.
Page 14
Sherlock Software Directory Structure Sherlock and associated software applications are installed in various directories on the GV 300-04. For reference, the following table lists the location and association of core programs and data directories that are referenced in this manual:...
Page 15
The License Manager The software installed on the GV 300 is license protected. The license is applied to the unit system number before it ships from the factory. Make sure that the product license matches what you ordered before going any further. Open the license manager from the “start menu”...
Page 16
4. Click on the iDiscover button to detect and configure cameras connected to the system. 5. Save Camera set (select which connected cameras you want to use). 6. Close iDiscover and launch iNspect Express (run panel shown below). GV 300 Installation Version 1.9; 2019-5-1...
Page 17
This program is a front-end configuration tool for iNspect Express. Launch from the icon on the GV 300 desktop. Select the language, camera type (always GigE for GV 300) and custom features for your application. These features are peculiar to the iNspect Express software and are detailed in the software users manual.
Page 18
The iDiscoverGenie utility is provided for discovering GigE cameras connected to the GV 300 camera ports. Use the iDiscover interface to change the camera IP settings to match the IP setting of the camera port. A shortcut to the iDiscover program is available on the GV 300 desktop.
Page 19
USB Installation Manual, or the PIC2592 Quick Start Guide. Note: Sherlock will fail to run if you enable Ifc but fail to point to a valid configuration file! 9. Close and reopen Sherlock. Driver changes only take effect when Sherlock opens. GV 300 Installation Version 1.9; 2019-5-1...
Page 20
Sherlock can load a configuration file at startup. If multiple configurations are needed, you can save them to different camera configuration files. Some example configuration files are included on the GV 300. NOTE: Changes to the camera settings are temporary, unless saved to the camera memory or to a configuration file.
Page 21
(shutter time) or Strobe pulse width (IO:Camera:SetNumberFeature) programmatically. When you launch the wizard you will see the dialog below. All cameras connected to the GV 300 should be listed in the device window. Click the “save” button to store the configuration in the SaperaLTDrv.ini file.
Page 22
Each time you run Sherlock it will use the order saved in the SaperaLTDrv.ini file, that is created by the wizard. The order does not change every time the GV 300 is rebooted. NOTE: Each time you open the Sapera Acquisition Wizard, the order will change to the order of discovery (or power-on order).
Page 23
Windows Enhanced Write Filter The GV 300 uses the Windows 7 Embedded operating system, which supports an Enhanced Write Filter (EWF) that provides the ability to write-protect a run-time image. By redirecting all write requests to an overlay disk or RAM partition, EWF allows the run-time image to maintain the appearance of a writeable run-time image.
Page 24
Specifications General Specifications This following table lists the specifications of the GV 300 vision system: Specification Definition Platform Processor Dual Core Atom D525 @ 1.86 GHz Windows7 Embedded (32 or 64-bit depending on model) Memory Storage 60GB Solid State Program...
Page 25
GV 300 Mechanical Dimensions Back View Bottom View GV 300 Installation Version 1.9; 2019-5-1...
Page 26
I/O Modules PL-USB Overview The PL-USB is an external I/O module for the GV 300. It provides trigger and power to up to 4 cameras as well as I/O for discrete application control. The PL-USB module simplifies hardware setup and provides a consistent I/O solution for iNspect Express and Sherlock.
Page 27
Refer to the DCI-101 Quick Start Guide for details and camera wiring diagrams. A copy is provided on the GV 300 system drive, the Sherlock DVD and the iNspect Express CD. Note: There is no software driver required for the DCI-101.