2-4 Off Timer Settings

To set monitor power-off time [Off Timer]

This function allows the monitor to automatically turn off after a specifi ed time
has passed. This function serves to reduce afterimages caused when the monitor
screen is left on for a long time period without use. Use this function when an
image is displayed throughout the day.
[Off Timer System]
Timer
ON time (1H - 23H)
Last 15 min. in "ON time" Advance Notice*
"ON time" expired
* When
is pressed during the advance notice period, the monitor continues to operate for
additional 90 minutes. Extension of operation time can be set without limitation.
[Procedure]
(1) Choose <Others> from the Adjustment menu, and press
(2) Choose <Off Timer> from the <Others> menu, and press
The <Off Timer> menu appears.
(3) Select "Enable" with
(4) Set a monitor ON time (1 to 23 hours) with
The Off Timer setting is completed.
[Resumption Procedure]
• Press
.
16
Chapter 2 Settings and Adjustments
Monitor
Operating
Power Off
or
, and press
.
or
Power Indicator
Blue
Flashing blue
Off
.
.
, and press
.
Attention
• The Off Timer functions even in the
power saving mode, but the advance
notice is disabled. The monitor power
is turned off without advance notice.