For more information about the TL70 Pro Modbus Modular Tower Light device registers, refer to document PN 243474.
Tower Light Segment Modes
Basic Segment Mode
Use a single run time register per LED segment to set it to Off, On, Flash, or Animation mode.
Use a single run time register for an audible segment to set it to Off or On.
Use additional configuration registers to change color, intensity, flash speed, and select animation type on LED segments 
and change volume and tone on audible segment.
Advanced Segment Mode
Use multiple run time registers per LED segment to control color, intensity, flash, and other animation types.
Use multiple run time registers for an audible segment to control sync, volume, and tone settings.
Use additional configuration registers to create custom intensity and flash speeds.
LED Segment Control
Animation
Off
Segment is off
Steady
Color 1 is solid on at defined intensity
Flash
Color 1 flashes at defined speed, color intensity, and pattern
Two Color Flash
Color 1 and Color 2 flash alternately at defined speed, color intensities, and pattern
50/50
Color 1 is displayed on 50% of the segment and Color 2 is displayed on the other 50% of the segment at the defined color intensities
Color 1 is displayed on 50% of the segment and Color 2 is displayed on the other 50% of the segment while rotating at the defined
50/50 Rotate
speed and color intensities
Color 1 is displayed as a single spot against the background of Color 2 while rotating at the defined speed, color intensities, and
Chase
rotational direction
Intensity Sweep
Color 1 repeatedly increases and decreases intensity between 0% to 100% at defined speed and color intensity
Demo
Demo sequence cycles through several sets of colors and configurations to highlight example applications
Audible Segment Control
Setting
Audible State
Sets the segment to off, on, or synced to flash pattern of last LED segment
Audible Volume
Defines the volume of the audible tone
Audible Tone
Defines the audible tone frequency
July 03, 2024
 
Modbus Configuration Instructions
© Banner Engineering Corp. All rights reserved.
Description
Description
page 6

Advertisement

loading
Need help?

Need help?

Do you have a question about the TL70 Pro Modbus Modular Tower Light and is the answer not in the manual?

This manual is also suitable for:

Sg-tl70p-lSg-tl70p-aTl70pm3qTl70pm3aqB-tl70pm-q