Chapter 9. Basic HSM, RFS and client configuration
To modify the RFS at a later date, select System > System configuration > Remote
file system, and then select the required action.
9.2.10.1. Systems configured for Remote Administration
Before using Remote Administration or configuring NTP, enable config push on
the nShield Connect for the RFS or client computer you intend to use for
configuration. The RFS config push is preferred unless the config push client is not
actually the same machine as the RFS. The RFS config push is recommended at
least when securely bootstrapping the configuration of the system from the
nShield Connect front panel.

9.2.11. Enabling config push from the RFS

On the nShield Connect display, use the right-hand navigation button to select
System > System configuration > Remote File System, and follow the steps
described in
Configuring the Remote File System
from the RFS, set the push mode to AUTO with RFS secure authentication
enabled (recommended), or to ON.
The RFS config push supports specifying secure authentication
from the nShield Connect front panel, whereas the client config
push only supports specifying authentication either from the
nShield Connect Serial Console
config file itself.

9.2.12. Enabling config push from a client computer

To enable config push from a client computer, on the nShield Connect display, use
the right-hand navigation button to select System > System configuration >
Config file options > Client config push > Config push mode, set ON or OFF, then
select CONFIRM. A confirmation message will be displayed.
After enabling config push, specify the IP address of the client to push the
configuration from. On the nShield Connect display, use the right-hand navigation
button to select System > System configuration > Config file options > Client
config push > Client address. Enter the IP address and select CONFIRM. A
message is displayed confirming your chosen IP address. Select CONTINUE.
Any remote computer is allowed to push configuration files if no
IP address or the 0.0.0.0 address is specified.