Belden HIRSCHMANN OpEdge-4D User Manual
Belden HIRSCHMANN OpEdge-4D User Manual

Belden HIRSCHMANN OpEdge-4D User Manual

Industrial ethernet firewall

Advertisement

Quick Links

User Manual
Installation
Industrial Ethernet Firewall
OpEdge-4D
Installation OpEdge-4D
Technical support
Release 01 12/2024
https://hirschmann-support.belden.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HIRSCHMANN OpEdge-4D and is the answer not in the manual?

Questions and answers

Summary of Contents for Belden HIRSCHMANN OpEdge-4D

  • Page 1 User Manual Installation Industrial Ethernet Firewall OpEdge-4D Installation OpEdge-4D Technical support Release 01 12/2024 https://hirschmann-support.belden.com...
  • Page 2 The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone. ©...
  • Page 3: Table Of Contents

    Contents Important information Safety instructions About this manual Description General device description Device views 1.2.1 Front view 1.2.2 Top view 1.2.3 Bottom view Power supply Ethernet ports 1.4.1 10/100/1000 Mbit/s twisted pair port 1.4.2 Pin assignments Display elements 1.5.1 Device status 1.5.2 Ethernet ports 1.5.3 Serial port (RS-232/RS-422/RS-485) Management interfaces...
  • Page 4 Operating the device Connecting data cables 2.6.1 Twisted Pair ports Filling out the inscription label Making basic settings First Login (Password) Monitoring the ambient air temperature Maintenance and service Disassembly Removing the device Technical data General technical data Power consumption/power output Dimension drawings Electromagnetic compatibility (EMC) Network range...
  • Page 5: Important Information

    Important information Note: Read these instructions carefully, and familiarize yourself with the device before trying to install, operate, or maintain it. The following notes may appear throughout this documentation or on the device. These notes warn of potential hazards or call attention to information that clarifies or simplifies a procedure.
  • Page 6 NOTICE NOTICE provides information about procedures that do not involve the risk of injury. Installation OpEdge-4D Release 01 12/2024...
  • Page 7: Safety Instructions

    Safety instructions WARNING UNCONTROLLED MACHINE ACTIONS To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices. Failure to follow these instructions can result in death, serious injury, or equipment damage.
  • Page 8: Strain Relief

     Install this device upright with the cooling slots positioned at the top and bottom of the module. The connected cables should not be bent, constricted, in close proximity to high amperage, or exposed to extreme temperatures.  Verify that there is at least 5 cm (2 in) of space above and below the device.
  • Page 9  Qualified personnel are familiar with appropriate measures against these hazards in order to reduce the risk for themselves and others.  Qualified personnel receive training on a regular basis. National and international safety regulations   Verify that the electrical installation meets local or nationally applicable safety regulations.
  • Page 10 Device variant Requirements All variants All of the following requirements are complied with:  The supply voltage corresponds to the voltage specified on the type plate of the device.  The power supply complies with the requirements as per NEC Class 2. ...
  • Page 11 Avertissement - Risque d'explosion - Ne pas débrancher tant que le circuit est sous tension à moins que l'emplacement soit connu pour ne contenir aucune concentration de gaz inflammable. WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. Avertissement - Risque d'explosion - La substitution de tout composant peut rendre ce matériel incompatible pour une utilisation en classe I, division 2.
  • Page 12  Install the device according to EN 60664-1 in an environment not exceeding degree of pollution 2.  Install the device in a suitable enclosure providing a degree of protection of at least IP54 according to EN 60079-0, taking into account the ambient conditions under which the equipment will be used.
  • Page 13 Supplier's Declaration of Conformity 47 CFR § 2.1077 Compliance Information OpEdge-4D U.S. Contact Information Belden – St. Louis 1 N. Brentwood Blvd. 15th Floor St. Louis, Missouri 63105, United States Phone: 314.854.8000 This device complies with part 15 of the FCC Rules. Operation is subject...
  • Page 14 Recycling note  The symbol of a crossed-out wheeled bin shown on the device indicates that the device MUST NOT be disposed of with household waste at the end of its service life. After its service life, the used device must be disposed of properly as electronic waste in accordance with the locally applicable disposal regulations.
  • Page 15: About This Manual

    About this manual The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device. The manual is available for download on the Internet: https:// www.doc.hirschmann.com Installation OpEdge-4D Release 01 12/2024...
  • Page 16: Key

    The symbols used in this manual have the following meanings:  Listing Work step  Subheading  Installation OpEdge-4D Release 01 12/2024...
  • Page 17: Description

     Serial port (RJ45)  Belden Horizon The devices provide you with a large range of functions, which the manuals for the operating software inform you about. You will find these manuals in the form of PDF files for downloading on the Internet on the Hirschmann product pages (https://www.doc.hirschmann.com).
  • Page 18: Device Views

    Device views 1.2.1 Front view 10-pin terminal block for power supply LED display element USB interface Serial port (RJ45) 4 × Gigabit Ethernet ports (RJ45) for 10/100/1000 Mbit/s Twisted pair connections IP address label MAC address label Installation OpEdge-4D Release 01 12/2024...
  • Page 19: Top View

    1.2.2 Top view 10-pin terminal block for power supply DIN rail clip 1.2.3 Bottom view microSD card interface Reset button DIN rail clip a. The microSD card interface has no functionality in the current release. Installation OpEdge-4D Release 01 12/2024...
  • Page 20: Power Supply

    Power supply For the power supply of the device, a 10-pin, screwable terminal block is available. For further information: See “Wiring the power supply” on page 28. Ethernet ports You can connect end devices and other segments to the device ports using twisted pair cables.
  • Page 21: Pin Assignments

    1.4.2 Pin assignments RJ45 10/100 Mbit/s 1000 Mbit/s MDI mode BI_DA+ TX− BI_DA− BI_DB+ — BI_DC+ — BI_DC− RX− BI_DB− — BI_DD+ — BI_DD− MDI-X mode BI_DB+ RX− BI_DB− BI_DA+ — BI_DD+ — BI_DD− TX− BI_DA− — BI_DC+ — BI_DC− Display elements After the supply voltage is set up, the software starts and initializes itself.
  • Page 22: Ethernet Ports

    Firmware update is underway. It will remain Green in this state until the update is complete. Internet status — None Belden Horizon is disabled or OpenVPN is NOT configured. Green Lights up The device is managed by a Belden Horizon account. Green Flashing A Belden Horizon tunnel is connected.
  • Page 23: Serial Port (Rs-232/Rs-422/Rs-485)

    1.5.3 Serial port (RS-232/RS-422/RS-485) These LEDs display port-related information. During the boot phase, they indicate the status of the boot process. The LEDs are directly located on the port. Display Color Activity Meaning Link status — none No console connection Green Flashes 1 time a period Device reboots with active console connection...
  • Page 24: Usb Interface

    Figure 2: Wiring diagram 1.6.2 USB interface Note: For information about the position on the device, see “Front view” on page 18 The USB socket has an interface for the local connection of an AutoConfiguration Adapter ACA22-USB (EEC). It is used for saving/loading the configuration data and diagnostic information, and for loading the software.
  • Page 25: Reboot

    1.7.1 Reboot  To reboot the device, press the Reset button for less than 10 seconds. For detailed information on rebooting the device via software, refer to the “User Manual Configuration”. The manual is available for download on the Internet: https:// www.doc.hirschmann.com 1.7.2...
  • Page 26: Installation

    Installation The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation. Perform the following work steps to install and configure the device:  Checking the package contents  Installing the device onto the DIN rail ...
  • Page 27: Grounding The Device

    Note: The overall shield of a connected shielded twisted pair cable is connected to the ground connector on the front panel as a conductor. To mount the device onto a horizontally mounted 35 mm DIN rail according to DIN EN 60715, proceed as follows: ...
  • Page 28: Wiring The Power Supply

    Figure 4: 10-pin terminal block Description not connected not connected not connected not connected not connected Power Input 2 (12 V DC ... 24 V DC) − Power 2 ground Functional ground connection − Power 1 ground Power Input 1(12 V DC ... 24 V DC) Table 5: Type and specification of the supply voltage, pin assignment on the device...
  • Page 29: Operating The Device

    Figure 5: 10-pin terminal block Description not connected not connected not connected not connected not connected Power Input 2 (12 V DC ... 24 V DC) − Power 2 ground Functional ground connection − Power 1 ground Power Input 1 (12 V DC ... 24 V DC) Table 6: Type and specification of the supply voltage, pin assignment on the device...
  • Page 30: Connecting Data Cables

    Connecting data cables 2.6.1 Twisted Pair ports Note the following general recommendations for data cable connections in environments with high electrical interference levels:  Keep the length of the data cables as short as possible.  Use optical data cables for the data transmission between the buildings. ...
  • Page 31: Making Basic Settings

    Making basic settings Note: 2 or more devices configured with the same IP address can cause unpredictable operation of your network. Install and maintain a process that assigns a unique IP address to every device in the network. The IP parameters must be entered when the device is installed for the first time.
  • Page 32: Monitoring The Ambient Air Temperature

    Monitoring the ambient air temperature Operate the device below the specified maximum ambient air temperature exclusively. See “Technical data” on page 35. The ambient air temperature is the temperature of the air at a distance of 5 cm (2 in) from the device. It depends on the installation conditions of the device, for example the distance from other devices or other objects, and the output of neighboring devices.
  • Page 33: Maintenance And Service

    Check regularly whether there is an updated version of the software that provides you with additional benefits. You find information and software downloads on the Belden product pages on the Internet: https://www.belden.com  Depending on the degree of pollution in the operating environment, check at regular intervals that the ventilation slots in the device are not obstructed.
  • Page 34: Disassembly

    Disassembly Removing the device  Disconnect the data cables.  Disable the supply voltage.  Disconnect the terminal block.  To remove the device from the DIN rail, press the device downwards and pull it out from under the DIN rail. Figure 6: Removal from the DIN rail Installation OpEdge-4D Release 01 12/2024...
  • Page 35: Technical Data

    Technical data General technical data General technical data Dimensions See “Dimension drawings” on page 36. W × H × D Weight OpEdge-4D 630 g (22.22 oz) Supply voltage Connection type 10-pin terminal block with screw lock for power supply Tightening 0.3 Nm (2.7 lb-in) torque Nominal voltage range...
  • Page 36: Dimension Drawings

    Dimension drawings 110,55 11,71 inch 4.35 0.30 0.46 45,4 1.79 53,11 2.09 Figure 7: Dimensions of the OpEdge-4D Installation OpEdge-4D Release 01 12/2024...
  • Page 37: Electromagnetic Compatibility (Emc)

    Electromagnetic compatibility (EMC) EMC interference emission Standard applications Radiated emission EN 61326-1 Class A FCC 47 CFR Part 15 Class A EMC interference immunity Standard applications Electrostatic discharge EN 61000-4-2 Contact discharge 4 kV EN 61000-4-2 Air discharge 8 kV Electromagnetic field EN 61000-4-3 80 MHz ...
  • Page 38: Scope Of Delivery

    Scope of delivery Number Article 1 × Device 1 × Safety and general information sheet 1 × Explosion warning sheet 1 × First login information sheet 1 × Open source information sheet 1 × 10-pin terminal block for power supply 1 ×...
  • Page 39: Accessories

    Accessories Note that products recommended as accessories may have different characteristics to those of the device, which may limit the application range of the overall system. For example, if you add an accessory with IP20 to a device with IP65, the IP of the overall system is reduced to IP20. Name Order number DB9 M to RJ45 adapter cable...
  • Page 40: 10 Underlying Technical Standards

    10 Underlying technical standards Designation ANSI/UL 121201 Nonincendive electrical equipment for use in class I and II, division 2 and class III, divisions 1 and 2 hazardous (classified) locations CSA C22.2 No. 213 Canadian National Standard(s) for Nonincendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations EN 60079-0 Explosive atmospheres –...
  • Page 41: Further Support

    For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You find the addresses of our partners on the Internet at https://www.belden.com. A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at https://hirschmann-support.belden.com.