Summary of Contents for Belden Hirschmann EAGLE40-4F

  • Page 1 User Manual Installation Industrial Ethernet Firewall EAGLE40-4F Installation EAGLE40-4F Technical support Release 01 12/2024 https://hirschmann-support.belden.com...
  • Page 2 The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone. ©...
  • Page 3: Table Of Contents

    Contents Important information Safety instructions About this manual Description General device description Device name and product code Device views 1.3.1 Front view 1.3.2 Top view 1.3.3 Bottom view Power supply Ethernet ports 1.5.1 10/100/1000 Mbit/s twisted pair port 1.5.2 Pin assignments Display elements 1.6.1 Device status 1.6.2 Ethernet ports...
  • Page 4 Wiring the power supply Operating the device Connecting data cables 2.7.1 Twisted Pair ports Filling out the inscription label Making basic settings First Login (Password) Monitoring the ambient air temperature Maintenance and service Disassembly Removing the device Technical data General technical data Power consumption/power output Dimension drawings Electromagnetic compatibility (EMC)
  • Page 5: Important Information

    Important information Note: Read these instructions carefully, and familiarize yourself with the device before trying to install, operate, or maintain it. The following notes may appear throughout this documentation or on the device. These notes warn of potential hazards or call attention to information that clarifies or simplifies a procedure.
  • Page 6 NOTICE NOTICE provides information about procedures that do not involve the risk of injury. Installation EAGLE40-4F Release 01 12/2024...
  • Page 7: Safety Instructions

    Safety instructions WARNING UNCONTROLLED MACHINE ACTIONS To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices. Failure to follow these instructions can result in death, serious injury, or equipment damage.
  • Page 8: Strain Relief

     Install this device upright with the cooling slots positioned at the top and bottom of the module. The connected cables should not be bent, constricted, in close proximity to high amperage, or exposed to extreme temperatures.  Verify that there is at least 5 cm (2 in) of space above and below the device.
  • Page 9  Qualified personnel are familiar with appropriate measures against these hazards in order to reduce the risk for themselves and others.  Qualified personnel receive training on a regular basis. National and international safety regulations   Verify that the electrical installation meets local or nationally applicable safety regulations.
  • Page 10 Device variant Requirements All variants All of the following requirements are complied with:  The supply voltage corresponds to the voltage specified on the type plate of the device.  The power supply complies with the requirements as per NEC Class 2. ...
  • Page 11 Avertissement - Risque d'explosion - Ne pas débrancher tant que le circuit est sous tension à moins que l'emplacement soit connu pour ne contenir aucune concentration de gaz inflammable. WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. Avertissement - Risque d'explosion - La substitution de tout composant peut rendre ce matériel incompatible pour une utilisation en classe I, division 2.
  • Page 12  Install the device according to EN 60664-1 in an environment not exceeding degree of pollution 2.  Install the device in a suitable enclosure providing a degree of protection of at least IP54 according to EN 60079-0, taking into account the ambient conditions under which the equipment will be used.
  • Page 13 Supplier's Declaration of Conformity 47 CFR § 2.1077 Compliance Information EAGLE40-4F U.S. Contact Information Belden – St. Louis 1 N. Brentwood Blvd. 15th Floor St. Louis, Missouri 63105, United States Phone: 314.854.8000 This device complies with part 15 of the FCC Rules. Operation is subject...
  • Page 14 Recycling note  The symbol of a crossed-out wheeled bin shown on the device indicates that the device MUST NOT be disposed of with household waste at the end of its service life. After its service life, the used device must be disposed of properly as electronic waste in accordance with the locally applicable disposal regulations.
  • Page 15: About This Manual

    About this manual The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device. The manual is available for download on the Internet: https:// www.doc.hirschmann.com Installation EAGLE40-4F Release 01 12/2024...
  • Page 16: Key

    The symbols used in this manual have the following meanings:  Listing Work step  Subheading  Installation EAGLE40-4F Release 01 12/2024...
  • Page 17: Description

    Description General device description The device is an Industrial Ethernet firewall designed for secure remote connectivity and Industrial Internet of Things (IIOT) applications. The device helps to enable secure and reliable device-to-device and device- to-cloud communications. The gateway includes a serial (RS-232/RS-422/ RS-485) port and multiple Ethernet ports, allowing for local connectivity to devices like PAC/PLCs, RTUs, DCS systems, smart instruments, electronic billboards, and communication towers.
  • Page 18 The Hirschmann network components help you ensure continuous communication across all levels of the company. Installation EAGLE40-4F Release 01 12/2024...
  • Page 19: Device Name And Product Code

    Device name and product code The device name corresponds to the product code. The product code is made up of characteristics with defined positions. The characteristic values stand for specific product properties. Item Product Character Description characteristic istic value 1 ... 7 Device EAGLE40 Security Router and Firewall (hyphen)
  • Page 20: Device Views

    Device views 1.3.1 Front view 10-pin terminal block for power supply LED display element USB interface Serial port (RJ45) 4 × Gigabit Ethernet ports (RJ45) for 10/100/1000 Mbit/s Twisted pair connections IP address label MAC address label Installation EAGLE40-4F Release 01 12/2024...
  • Page 21: Top View

    1.3.2 Top view 10-pin terminal block for power supply DIN rail clip 1.3.3 Bottom view microSD card interface Reset button DIN rail clip a. The Reset button has no functionality in the current release. Installation EAGLE40-4F Release 01 12/2024...
  • Page 22: Power Supply

    Power supply For the power supply of the device, a 10-pin, screwable terminal block is available. For further information: See “Wiring the power supply” on page 32. Ethernet ports You can connect end devices and other segments to the device ports using twisted pair cables.
  • Page 23: Pin Assignments

    1.5.2 Pin assignments RJ45 10/100 Mbit/s 1000 Mbit/s MDI mode BI_DA+ TX− BI_DA− BI_DB+ — BI_DC+ — BI_DC− RX− BI_DB− — BI_DD+ — BI_DD− MDI-X mode BI_DB+ RX− BI_DB− BI_DA+ — BI_DD+ — BI_DD− TX− BI_DA− — BI_DC+ — BI_DC− Display elements After the supply voltage is set up, the software starts and initializes itself.
  • Page 24: Ethernet Ports

    Display Color Activity Meaning Virtual Private — None At least one of the following cases applies: Network  The VPN status display is switched off.  No VPN connection is active.  No active VPN connection is in the "up" status.
  • Page 25: Serial Port (Rs-232/Rs-422/Rs-485)

    1.6.3 Serial port (RS-232/RS-422/RS-485) These LEDs display port-related information. During the boot phase, they indicate the status of the boot process. The LEDs are directly located on the port. Display Color Activity Meaning Link status — none No console connection Green Flashes 1 time a period Device reboots with active console connection...
  • Page 26: Usb Interface

    Figure 2: Wiring diagram 1.7.2 USB interface Note: For information about the position on the device, see “Front view” on page 20 The USB socket has an interface for the local connection of an AutoConfiguration Adapter ACA22-USB (EEC). It is used for saving/loading the configuration data and diagnostic information, and for loading the software.
  • Page 27: Microsd Card Interface

    1.7.3 microSD card interface Note: For information about the position on the device, see “Bottom view” on page 21 This is an optional accessory. The microSD card interface is located on the bottom of the device. Any industrial microSD card (15 mm 12 mm ×...
  • Page 28: Reset Button

    Reset button For information about the position on the device, see “Bottom view” on page 21 Note: The Reset button has no functionality in the current release. You will find detailed information for performing a factory reset in the software manual “User Manual Configuration”...
  • Page 29: Installation

    Installation The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation. Perform the following work steps to install and configure the device:  Checking the package contents  Installing the device onto the DIN rail ...
  • Page 30: Inserting The Microsd Card

    Inserting the microSD card The microSD card interface uses a push/push latch mechanism to insert and remove the microSD card. Note: After inserting the microSD card, be careful NOT to eject or damage it when standing up the device. Note: To help prevent data loss, make sure the device is NOT powered when inserting or removing the microSD card.
  • Page 31: Grounding The Device

    Figure 3: Mounting on the DIN rail Grounding the device The device has a functional ground connection. The device is grounded via the 10-pin terminal block that is located at the top of the device.  Wire the 10-pin terminal block according to the following figure that shows the pin assignments for the functional ground connection: Figure 4: 10-pin terminal block Description...
  • Page 32: Wiring The Power Supply

    Description not connected not connected not connected Power Input 2 (12 V DC ... 24 V DC) − Power 2 ground Functional ground connection − Power 1 ground Power Input 1 (12 V DC ... 24 V DC) Table 6: Type and specification of the supply voltage, pin assignment on the device Wiring the power supply...
  • Page 33: Operating The Device

    Description not connected not connected not connected Power Input 2 (12 V DC ... 24 V DC) − Power 2 ground Functional ground connection − Power 1 ground Power Input 1 (12 V DC ... 24 V DC) Table 7: Type and specification of the supply voltage, pin assignment on the device ...
  • Page 34: Filling Out The Inscription Label

     Verify that power supply cables and data cables do not run parallel over longer distances. To reduce inductive coupling, verify that the power supply cables and data cables cross at a 90 ° angle.  Use shielded data cables for gigabit transmission via copper cables, for example SF/UTP cables according to ISO/IEC 11801.
  • Page 35: Making Basic Settings

    Making basic settings Note: 2 or more devices configured with the same IP address can cause unpredictable operation of your network. Install and maintain a process that assigns a unique IP address to every device in the network. The IP parameters must be entered when the device is installed for the first time.
  • Page 36 Note: If you lost your password, then use the System Monitor to reset the password. For further information see: https://hirschmann-support.belden.com/en/kb/required-password-change- new-procedure-for-first-time-login Installation EAGLE40-4F Release 01 12/2024...
  • Page 37: Monitoring The Ambient Air Temperature

    Monitoring the ambient air temperature Operate the device below the specified maximum ambient air temperature exclusively. See “Technical data” on page 40. The ambient air temperature is the temperature of the air at a distance of 5 cm (2 in) from the device. It depends on the installation conditions of the device, for example the distance from other devices or other objects, and the output of neighboring devices.
  • Page 38: Maintenance And Service

    Check regularly whether there is an updated version of the software that provides you with additional benefits. You find information and software downloads on the Belden product pages on the Internet: https://www.belden.com  Depending on the degree of pollution in the operating environment, check at regular intervals that the ventilation slots in the device are not obstructed.
  • Page 39: Disassembly

    Disassembly Removing the device  Disconnect the data cables.  Disable the supply voltage.  Disconnect the terminal block.  To remove the device from the DIN rail, press the device downwards and pull it out from under the DIN rail. Figure 6: Removal from the DIN rail Installation EAGLE40-4F Release 01 12/2024...
  • Page 40: Technical Data

    Technical data General technical data General technical data Dimensions See “Dimension drawings” on page 41. W × H × D Weight EAGLE40-4F 630 g (22.22 oz) Supply voltage Connection type 10-pin terminal block with screw lock for power supply Tightening 0.3 Nm (2.7 lb-in) torque Nominal voltage range...
  • Page 41: Dimension Drawings

    Dimension drawings 110,55 11,71 inch 0.30 4.35 0.46 45,4 1.79 53,11 2.09 Figure 7: Dimensions of the EAGLE40-4F Installation EAGLE40-4F Release 01 12/2024...
  • Page 42: Electromagnetic Compatibility (Emc)

    Electromagnetic compatibility (EMC) EMC interference emission Standard applications Radiated emission EN 61326-1 Class A FCC 47 CFR Part 15 Class A EMC interference immunity Standard applications Electrostatic discharge EN 61000-4-2 Contact discharge 4 kV EN 61000-4-2 Air discharge 8 kV Electromagnetic field EN 61000-4-3 80 MHz ...
  • Page 43: Network Range

    Network range 10/100/1000 Mbit/s twisted pair port Length of a twisted pair segment max. 100 m (328 ft) (for Cat5e cable) Table 8: Network range: 10/100/1000 Mbit/s twisted pair port Installation EAGLE40-4F Release 01 12/2024...
  • Page 44: Order Numbers

    Order numbers Device Order number EAGLE40-044T1TW9XHS9ANFXX.X.XX 942333001 No additional modules, firewall only EAGLE40-044T1TW9XHS9AUNXX.X.XX 942333002 Unified Protection Suite (All Enforcers: DNP3 + Modbus + OPC) Installation EAGLE40-4F Release 01 12/2024...
  • Page 45: Scope Of Delivery

    Scope of delivery Number Article 1 × Device 1 × Safety and general information sheet 1 × Explosion warning sheet 1 × Open source information sheet 1 × 10-pin terminal block for power supply 1 × DB9 M to RJ45 adapter cable 1 ×...
  • Page 46: 10 Accessories

    10 Accessories Note that products recommended as accessories may have different characteristics to those of the device, which may limit the application range of the overall system. For example, if you add an accessory with IP20 to a device with IP65, the IP of the overall system is reduced to IP20. Name Order number DB9 M to RJ45 adapter cable...
  • Page 47: 11 Underlying Technical Standards

    11 Underlying technical standards Designation ANSI/UL 121201 Nonincendive electrical equipment for use in class I and II, division 2 and class III, divisions 1 and 2 hazardous (classified) locations CSA C22.2 No. 213 Canadian National Standard(s) for Nonincendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations EN 60079-0 Explosive atmospheres –...
  • Page 48: Further Support

    For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You find the addresses of our partners on the Internet at https://www.belden.com. A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at https://hirschmann-support.belden.com.