Panasonic S-LINKV SL-VEU Instruction Manual

Flexible wire-saving system

Advertisement

Quick Links

INSTRUCTION
MANUAL
Flexible Wire-saving System S-LINKV
End Unit
SL-VEU
MJE-SLVEU No.0097-84V
Thank you very much for purchasing Panasonic
products. Read this Instruction Manual carefully and
thoroughly for the correct and optimum use of this
product. Kindly keep this manual in a convenient
place for quick reference.
Never use this product in a device for personnel
protection.
In case of using sensing devices for personnel
protection, use products which meet laws and
standards, such as OSHA, ANSI or IEC etc., for
personnel protection applicable in each region
or country.
Before handling this product, remove any elec-
trostatic charge that may be present on your
body. There is a danger of this product getting
damaged due to the electrostatic charge.
For the overall description of S-LINK V system,
refer to "S-LINK V User's Manual."
1
FUNCTIONAL DESCRIPTION
Designation
Function
1
Power indicator (Green) Lights up when power is ON.
Signal line connection
Lights up when signal wave-
2
indicator (Orange)
2
CONNECTION
Each system of the S-LINK V system needs at
least 1 end unit. If this product is not connected,
the system may not operate properly.
If the branch line length is equal to the main line
length, connect this product to the line having
fewer nodes (units).
Be sure to connect 1 end unit to the end of the
main line.
If the branch line length exceeds 80% of the maxi-
mum transmission distance, connect 1 end unit to
the end of the branch line, too.
Up to 2 end units can be connected for 1 system.
<If the branch line length is equal to the main line length>
Same length (Note 1)
SL-VEU
Connect the end unit to
the line having fewer
nodes.
<If the branch line length is 80% of the main line length or more>
Main line
SL-VEU
Max. transmission distance
Connect the
80% of the main line length or more
end unit to the
main line and
branch line,
respectively.
Notes: 1) Even if the cable lengths are the same, if both the main
and branch line lengths exceed 80% of the maximum
transmission distance, connect 2 end units.
2) The maximum transmission distance depends on the
cable conductor cross section and the number of nodes.
For details, refer to "S-LINK V User's Manual."
3) Wiring that exceeds the maximum transmission distance
or the total cable length cannot be done.
For details, refer to "S-LINK V User's Manual."
3
DIN RAIL MOUNTING HOLDER
MS-CH (ACCESSORY)
ing holder MS-CH (accessory).
How to mount MS-CH
<Mounting on a 35mm width DIN rail>
1. Fit the rear part of MS-CH on
a 35mm width DIN rail.
2. Press down the front part of
2
MS-CH
it to the DIN rail.
35mm width DIN rail
How to remove MS-CH
2
1. Push MS-CH forward.
2. Lift up the front part of MS-CH
to remove it.
Note: Take care that if the front part is lifted without pushing MS-CH
forward, the hook on the rear portion is likely to break.
<Mounting with screws>
M4 pan-head screws
• Use M4 pan-head screws.
Please
arrange
The tightening torque
separately.
should be 1.2N·m or less.
Note: M4 pan-head screw is not enclosed with MS-CH.
Please arrange separately.
How to mount SL-VEU
• Press down this product
on the MS-CH.
How to remove SL-VEU
1.
2. Tip the screwdriver in the direction of the arrow to
remove.
2
1
4
SPECIFICATIONS
Type
Item
Model No.
-
Supply voltage
24V DC±10% or less
Current consumption
10mA or less
-10 to +55°C
Ambient
(No dew condensation or icing allowed) (Note)
temperature
Storage: -20 to +70°C
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Enclosure: Polycarbonate
Material
DIN rail mounting holder: ABS
2
Cable
0.5mm
Weight
Approx. 45g (including MS-CH)
1
Accessory
MS-CH (DIN rail mounting holder): 1pc.
Note: If this product is stored in the control panel together with
the other units, the temperature may rise above the spec-
1
the other units.
In this case, install a cooling fan, etc. so that the ambient
5
CAUTIONS
This product has been developed / produced for
industrial use only.
MS-CH.
Panasonic Industry Co., Ltd.
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
https://industry.panasonic.com/
Please visit our website for inquiries and about our sales network.
Panasonic Industry Co., Ltd. 2024
April, 2024
End unit
SL-VEU
PRINTED IN JAPAN

Advertisement

loading
Need help?

Need help?

Do you have a question about the S-LINKV SL-VEU and is the answer not in the manual?

Questions and answers

Summary of Contents for Panasonic S-LINKV SL-VEU

  • Page 1 Power indicator (Green) Lights up when power is ON. Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH a 35mm width DIN rail. Thank you very much for purchasing Panasonic Signal line connection Lights up when signal wave- Enclosure: Polycarbonate 2.
  • Page 2 0.6m 45g MS-CH 35mm DIN MS-CH DIN S-LINK V MS-CH MS-CH OSHA ANSI MS-CH • M4 1.2N m S-LINK V S-LINK V SL-VEU MS-CH SL-VEU • MS-CH SL-VEU SL-VEU MS-CH S-LINK V S-LINK V https://industry.panasonic.com/ Panasonic Industry Co., Ltd. 2024...