Download Print this page

DCS WD-27-SS-OD Specifications page 2

Outdoor kitchen essentials
Hide thumbs Also See for WD-27-SS-OD:

Advertisement

BGB131
BGB132
BGB131-BI
Built-in Side Burner Dimensions
BGB131-BI Single Side Burner
BGB132-BI Double Side Burner
Professional Side Burner
Island Preparation
8
B
B
B
8
Note: the deck is
not required
Warming Drawer Dimensions
BGB132-BI
MODEL NUMBER
30" CART MOUNT
BUILT-IN
MODEL
A
B
SIDE BURNER(S)
BGB131-BI
12"
6" min.
SHIPPING WEIGHT
BGB132-BI
22-3/8"
6" min.
SHIPPING DIMENSIONS
Ordering Data: Please specify gas type (natural or propane) when ordering.
Gas Requirements:
Natural
• 1/2" NPT male with a 3/8" flare adapter
• Operational Pressure: 4" W.C.
• Supply Pressure: 6" to 9" W.C.
POWER
CORD
30" Cart Mount Side Burner Dimensions
BGB131 Single Side Burner
BGB132 Double Side Burner
NOTE: Cart Mount Side Burners are not designed for built-in applications.
BGB131

1 @ 17,000 Btu/hr
35.4
(LBS)
13.5 x 14.5 x 19
(HEIGHT X WIDTH X DEPTH)
Warming Drawer Island Preparation
1-1/2" min. to
bottom of
countertop
MODEL NUMBER
WD-27-SS-OD
DRAWER SPACE
1.6 CUBIC FEET
REMOVABLE SHELF/SERVING TRAY
TYPE 304 STAINLESS STEEL
BGB131-BI
BGB132
BGB132-BI



1 @ 17,000 Btu/hr
2 @ 17,000 Btu/hr
2 @ 17,000 Btu/hr
35.8
60.6
64.0
13.5 x 14.5 x 19
16 x 18 x 30
16 x 18 x 30
Propane
• 1/2" NPT male with a 3/8" flare adapter
• Operational Pressure: 10" W.C.
• Supply Pressure: 11" to 14" W.C.
A 120 Volt AC GFI
outlet should be
located below the
Warming Drawer
2 x 4's or similar
support
min. cabinet depth
Power Requirements:
• 120V 60Hz
• 3 wire

• 15 amp circuit

Summer 2008
43

Advertisement

loading

This manual is also suitable for: