FP500-ADA-C (Coin Accepting) Waist High Swing Gate Service & Installation Manual Note: Successful turnstile installation depends on reading this manual. Please keep this service manual after installation. If an installation is done by a construction company or outside installer, please pass this book along to the end user. This book is required for maintenance, troubleshooting &...
Canadian Electrical Code, CSA C22.1, Part I, Safety Standard for Electrical Installations The 6500 Series Control Head is suitable for indoor & outdoor use, within in an appropriate turnstile or gate model. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
We’re the #1 Choice of Top Architects, Security Pros and Engineers For more than 30 years, Controlled Access has been the globally trusted name in pedestrian control equipment. Made in Ohio and shipped worldwide, we are the first choice of leading architects, facility managers, security consultants, and engineers.
Page 5
• Additional options available upon request CAN/ULC S319 & CSA C22.2#247 • Arm Length: 36" (914.4mm) 4008027 Controlled Access, Inc. is certified * Dimensions are subject to change without notice by Advantage International Registrar to be an ISO 9001:2015 company...
The larger front panel can be taken out by removing the two 10/32 Phillips screws that connect the front panel to the cabinet located at the upper inside of the cabinet. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
(reference hydraulic shock information later in this manual). Reinstall the front panel and lid on the cabinet then provide this manual to the end user or leave within the cabinet for future reference. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Anchor spacing and edge distance (anchor installation locations) are the responsibility of the engineer of record. Installing product in oversized holes is not recommended. Product will not set properly or achieve full designed load in oversized holes. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
100-240 VAC (single phase) receptacle. The power supply will automatically set itself to function on your local voltage and convert it to 24VDC. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Phone: (800)942-0829 Complete control heads are Fax: (800)942-0828 available upon request. Web: www.controlledaccess.com Contact us for pricing details. Email: sales@controlledaccess.com Control Head Castings Locking Bar Assemblies – I2 IB IC ID IE 0373 - Bottom Casting 0382 - Fail Open Assembly XD10 0740 - Logic Controller (XD10) $219.65...
Note that the key override option makes conversion between fail lock and fail open very di cult to accomplish and also may not be available for some turnstile or gate models. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Fail Open Fail Lock Fail Lock Fail Open Pivot Point Pivot Point Pivot Point Pivot Point Direction 1 Solenoid Direction 2 Solenoid 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Page 14
Make sure the solenoid spring is between the alignment tabs on the linkage or the assembly may bind when pivoting. Correct Alignment Incorrect Alignment Locking Bar Linkage Spring Alignment Tabs Solenoid Spring 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Failure to turn the shock back out after threading it in all of the way will likely cause the part to wear out very quickly. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Dir 2 Fail Open Dir 1 Green Light Dir 1 Red Light Dir 2 Green Light Dir 2 Red Light XD10 Logic Controller Control Board 0740 0789 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
6500 Series Control Head w/ XD10 Controller Standard Wiring Diagram Direction 1 Direction 2 Direction 1 Direction 2 Access Control Relay Access Control Relay Override Relay Override Relay N.O. N.O. N.O. N.O. Input Voltage: 100-240 VAC 1 Phase 1.1 - .6A Max 50/60 Hz 24V 2.5A Grounding Tab...
As a side note, indicator lights purchased from Controlled Access, Inc. can also be wired to glow yellow. If desired, this can be used instead of red with the unused white wire on the light’s cable to indicate to pedestrians they require credentials to enter. This is especially handy for multi-lane installations in which some directions are “no passage”...
PLC software version. number (if known), enter it as a value then press B to save. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
If there are other issues with operation, check out the troubleshooting guide for additional diagnostic procedures or call Controlled Access, Inc. for assistance. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Options and con gurations may alter the quantity or layout of the limit switches. Some examples of this would be electronically controlled one direction turnstiles, turnstiles with counters and turnstiles equipped with home position switches. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Please include contact information so we can call to discuss any issues your control head may have. Please note that any repairs that cost under $500.00 will require a credit card payment before being returned. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Illustrated above is the same dashed circle with a chain tensioner assembly adjusted to four 90 degree increments While the outer radius changes, the inner pivot point remains the same. Loose Chain Tensioned Chain 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Disconnect access control from logic controller. Preform testing Access control device procedures on page 20. If the malfunction. turnstile works properly, contact manufacturer of access control device. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Page 25
Shim the unit from the oor if necessary. Turnstile seems to be binding Rotor is not plumb / turnstile mechanically. body is not level. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Page 26
Refer to page 19. Please contact us for any other Other problems. issues. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
- Piggybacking : More than one user trying to squeeze through the turnstile on one rotation should be avoided. Large bags and carts should be brought through an alternate means of entrance. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Warranty Information Seller warrants the goods against defective workmanship and materials provided that Buyer notify Seller within one (1) year after receipt by Buyer of the goods of any claim under this Warranty. The liability of Seller shall be limited to replacing or repairing defective goods returned by Buyer and delivered to the factory of the Seller, transportation charges prepaid.
While we o er limited support on the coin acceptor, the manufacturer of the mechanism is a better source of assistance. Contact Microsystems Controls by calling (702) 643-1600. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
FP500-ADA-C Service & Installation Manual SP 115 www.microcoin.com 115mm face plate. Ultra-compact. Stylish and appealing design. Unique “Parallel Path” debris release. Conforms to industry standards. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Page 31
ISO9001 certified manufacturing plants and an international network of offices and market representation in Australia, Hong Kong, the United Kingdom, the USA. Printed 00.00 www.microcoin.com 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
To reset the credit to zero, simply open the SP housing by pressing the reject lever and then release, whilst in this mode. MicrosystemControls August 2007 SP-PB-OBP Instructions.doc Page 1 of 3 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Page 34
Finish Briefly press button x 1 to complete. “M” LED will go steady GREEN MicrosystemControls August 2007 SP-PB-OBP Instructions.doc Page 2 of 3 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
Page 35
SP will attempt to continue the OBP function from where the error occurred. If the problem persists, then escape the sequence. (see Escape above) MicrosystemControls August 2007 SP-PB-OBP Instructions.doc Page 3 of 3 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...