Controlled Access BR5500 Service & Installation Manual

Waist high turnstile

Advertisement

Quick Links

BR5500 Waist High Turnstile
Service & Installation Manual
Note: Successful turnstile installation depends on reading this manual.
Please keep this service manual after installation. If an installation is done by a construction company
or outside installer, please pass this book along to the end user. This book is required for maintenance,
troubleshooting & repairs.
Service Manual: 0740 E Gen. 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BR5500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Controlled Access BR5500

  • Page 1 BR5500 Waist High Turnstile Service & Installation Manual Note: Successful turnstile installation depends on reading this manual. Please keep this service manual after installation. If an installation is done by a construction company or outside installer, please pass this book along to the end user. This book is required for maintenance, troubleshooting &...
  • Page 2: Important Electrical Information

    Canadian Electrical Code, CSA C22.1, Part I, Safety Standard for Electrical Installations The 6500 Series Control Head is suitable for indoor & outdoor use, within in an appropriate turnstile or gate model. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 3: Table Of Contents

    Electrical Introduction Wiring Diagram Wiring Legend Logic Controller Settings Testing Procedure Limit Switch & Limit Switch Cam Information Maintenance & Cleaning Troubleshooting Proper Turnstile Usage Warranty Appendix 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 4: Model Datasheet

    We’re the #1 Choice of Top Architects, Security Pros and Engineers Built in the USA For more than 30 years, Controlled Access has been the globally trusted name in pedestrian control equipment. Made in Ohio and shipped Standard powder coating color selections: worldwide, we are the first choice of leading architects, facility managers, Additional colors available and can be quoted upon request.
  • Page 5 • Cover is constructed with (16 gauge) 304 4008027 Warranty: stainless steel, No. 4 satin finish Controlled Access, Inc. is certified • Arm assembly constructed with 1 5/16" Units are warranted against defects in materials by Advantage International Registrar (33.4mm) diameter, (12 gauge) stainless steel...
  • Page 6: Concrete Anchor Information

    Anchor spacing and edge distance (anchor installation locations) are the responsibility of the engineer of record. Installing product in oversized holes is not recommended. Product will not set properly or achieve full designed load in oversized holes. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 7: Installation Instructions

    (reference hydraulic shock information later in this manual). Reinstall the front panel and lid on the cabinet then provide this manual to the end user or leave within the cabinet for future reference. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 8: Mechanical Overview

    100-240 VAC (single phase) receptacle. The power supply will automatically set itself to function on your local voltage and convert it to 24VDC. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 9: Internal Parts Breakdown

    BR5500 Waist High Turnstile Service & Installation Manual 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 10: Parts List

    Phone: (800)942-0829 Complete control heads are Fax: (800)942-0828 available upon request. Web: www.controlledaccess.com Contact us for pricing details. Email: sales@controlledaccess.com Control Head Castings Locking Bar Assemblies – I2 IB IC ID IE 0373 - Bottom Casting 0382 - Fail Open Assembly XD10 0740 - Logic Controller (XD10) $219.65...
  • Page 11: Control Head Con Gurations

    Note that the key override option makes conversion between fail lock and fail open very di cult to accomplish and also may not be available for some turnstile or gate models. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 12: Locking Bar Information

    Fail Open Fail Lock Fail Lock Fail Open Pivot Point Pivot Point Pivot Point Pivot Point Direction 1 Solenoid Direction 2 Solenoid 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 13 Make sure the solenoid spring is between the alignment tabs on the linkage or the assembly may bind when pivoting. Correct Alignment Incorrect Alignment Locking Bar Linkage Spring Alignment Tabs Solenoid Spring 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 14: Hydraulic Shock & Indexing

    Failure to turn the shock back out after threading it in all of the way will likely cause the part to wear out very quickly. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 15: Electrical Introduction

    Dir 2 Fail Open Dir 1 Green Light Dir 1 Red Light Dir 2 Green Light Dir 2 Red Light XD10 Logic Controller Control Board 0740 0789 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 16: Wiring Diagram

    6500 Series Control Head w/ XD10 Controller Standard Wiring Diagram Direction 1 Direction 2 Direction 1 Direction 2 Access Control Relay Access Control Relay Override Relay Override Relay N.O. N.O. N.O. N.O. Input Voltage: 100-240 VAC 1 Phase 1.1 - .6A Max 50/60 Hz 24V 2.5A Grounding Tab...
  • Page 17: Wiring Legend

    As a side note, indicator lights purchased from Controlled Access, Inc. can also be wired to glow yellow. If desired, this can be used instead of red with the unused white wire on the light’s cable to indicate to pedestrians they require credentials to enter. This is especially handy for multi-lane installations in which some directions are “no passage”...
  • Page 18: Logic Controller Settings

    PLC software version. number (if known), enter it as a value then press B to save. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 19: Testing Procedure

    If there are other issues with operation, check out the troubleshooting guide for additional diagnostic procedures or call Controlled Access, Inc. for assistance. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 20: Limit Switch & Limit Switch Cam Information

    Options and con gurations may alter the quantity or layout of the limit switches. Some examples of this would be electronically controlled one direction turnstiles, turnstiles with counters and turnstiles equipped with home position switches. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 21: Maintenance & Cleaning

    Please include contact information so we can call to discuss any issues your control head may have. Please note that any repairs that cost under $500.00 will require a credit card payment before being returned. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 22: Troubleshooting

    Disconnect access control from logic controller. Preform testing Access control device procedures on page 19. If the malfunction. turnstile works properly, contact manufacturer of access control device. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 23 Shim the unit from the oor if necessary. Turnstile seems to be binding Rotor is not plumb / turnstile mechanically. body is not level. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 24 Refer to page 18. Please contact us for any other Other problems. issues. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 25: Proper Turnstile Usage

    - Piggybacking : More than one user trying to squeeze through the turnstile on one rotation should be avoided. Large bags and carts should be brought through an alternate means of entrance. 0740E Gen 3. Controlled Access, Inc. (800) 942-0829 | (330) 273-6185 | Sales@controlledaccess.com...
  • Page 26: Warranty

    Warranty Information Seller warrants the goods against defective workmanship and materials provided that Buyer notify Seller within one (1) year after receipt by Buyer of the goods of any claim under this Warranty. The liability of Seller shall be limited to replacing or repairing defective goods returned by Buyer and delivered to the factory of the Seller, transportation charges prepaid.