Advertisement

Quick Links

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch;
do not use any phone in your
building.
Immediately call your gas
supplier from your neighbor's
phone. Follow the gas suppliers
instructions.
If you cannot reach your gas
supplier call the fire department.
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE.
Gas Fireplace
Insert
Models: A125
Homeowner's Installation
and Operating Manual
����
�������� �����
�����
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A132
C E RT I F I E D
10002964 2/08 Rev. 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A125 and is the answer not in the manual?

Questions and answers

Summary of Contents for Majestic A125

  • Page 1 Gas Fireplace SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND Insert USING APPLIANCE WARNING! Models: A125 IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED A132 EXACTLY, A FIRE OR EXPLO- SION MAY RESULT CAUSING PROPERTY DAMAGE, PER- SONAL INJURY OR LOSS OF LIFE.
  • Page 2: Table Of Contents

    Gas Fireplace Insert Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace insert. IMPORTANT - Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the manufacturers' warranty.
  • Page 3: Installation & Operating Instruction

    fireplace. 1. This appliance gives off high temperatures and should be located out of high traffic areas and away from furniture and A125 / A132 draperies. Certified To 2. Children and adults should be alerted to the hazards of the ANSI Z 21.88-2005 / CSA 2.33-2005...
  • Page 4: Fireplace & Trim Dimensions

    Gas Fireplace Insert Zero Clearance Kit Maintain 1” Clear- ance to ‘B’ Vent 4“ Air Inlet Channel Gas Inlet Knock-out A125 A132 R - Fireplace Opening Width 26³⁄₄” (680 mm) 26⁵⁄₈” (676 mm) Q - Fireplace Opening Height S - Depth of Insert 38¹⁄₂”...
  • Page 5: Locating Your Fireplace Insert

    Fig. 1 Locating unit with zero clearance kit. (305 mm) above floor level, no hearth is required. A) Flat on wall Cross corner A 3” diameter (for A125) or 4” diameter (for A132) Island *Room divider Class ‘B’ vent must be used when installing the fire-...
  • Page 6: Combustion Air

    Gas Fireplace Insert Combustion Air High Elevations It is very important that an adequate air supply is Input ratings are shown in BTU per hour and are available when the unit is being operated. Since most certified without deration for elevations up to homes of today are tightly sealed and insulated, addi- 4,500 feet (1,370m) above sea level.
  • Page 7: Gas Supply Pressures

    Gas Fireplace Insert When using copper or flex connector, use only Trim Top approved fittings. Always provide a union when using black iron pipe so the gas line can be easily Trim Left Side disconnected for burner or fan servicing. See gas Wiring specifications for pressure details and ratings.
  • Page 8: Venting Instructions

    fireplace. 3. To assure top performance, safety and efficiency, all inserts must be installed with an approved 4" diameter flue liner, with exception of A125, which 0 To 10' should be installed with an approved 3" liner,as per CSA-B.149 or National Fuel Code ANSI Z223/NFPA...
  • Page 9: Common Flue Installations

    Insert liner from top of chimney through the damper cigarette is drawn into the fireplace. If it is not, turn opening and attach to 3" flue collar (for A125); 4" flue the unit off and check for causes creating the lack of collar (for A132).
  • Page 10: Fan Kit Installation

    Gas Fireplace Insert Fan Removal Instructions Fan Kit Installation 115 Volt, 60 Hz. 56W 1. Turn off gas and electricity. 2. Remove the front glass. The fan kit includes the following: fan, temperature 3. Remove the logs. sensor, speed control and a 6 ft. cord. The following explains how to start and set the fan for automatic 4.
  • Page 11: Operating Instructions

    Ensure the log is securely in place. It will be necessary to clean the glass periodically. 6. A125: Place front left log (N13) onto locator. Ensure During start-up, condensation, which is normal, forms the log is securely in place.
  • Page 12: Large Lava Rock Placement

    Gas Fireplace Insert Front Right Log Figure 17 Right Rear Log Left Rear Log A125 Front Left Log LG479 Ember Material Front Right Log Figure 18 A132 Right Rear Log Left Rear Log Front Left Log ����� ���� ���� �����...
  • Page 13: Flame Characteristics

    After each lighting, vapor may condense and fog the glass; this moisture disap- pears within a few minutes of burning. SIT Pilot F584-703 Fig. 21 Correct pilot flame appearance. Figure 23 A125 F584-703 Honeywell & PSE pilot flames LG480 Figure 23 A132 �����...
  • Page 14: Lighting & Operating Instructions

    Gas Fireplace Insert Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- instructions.
  • Page 15: Troubleshooting Gas Control (820 Millivolt Gas Valve)

    Gas Fireplace Insert Troubleshooting the Gas Control System SIT NOVA 820 Millivolt Valve NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. WARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION...
  • Page 16: Troubleshooting Gas Control (Honeywell)

    Gas Fireplace Insert Troubleshooting the Gas Control System Honeywell Millivolt Valve START CHECK Gas Supply On Supply Line Hooked Up Shutoff Valve Open Lockout Has Engaged. Wait 60 Seconds And Try Again. For Spark At Electrode While Pilot Lights With Depressing Piezo —...
  • Page 17: Maintenance

    Gas Fireplace Insert Maintenance Burner and Burner Compartment It is important to keep the burner and the burner In order to properly clean the burner and pilot assembly, compartment clean. At least once per year the logs and turn off the gas to the unit, remove the window frame lava rock/ember material should be removed and the panel and logs exposing the burner and pilot assembly.
  • Page 18: Replacement Parts

    9a/b ��� 11a/b 23a/b 22a/b CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. A125, A132 Gas Insert 2964 A125/132 parts Ref. Description 11/06 A125 A132 1.
  • Page 19 Gas Fireplace Insert A125, A132 Gas Insert Ref. Description A125 A132 9a. Orifice Pilot PSE - Nat. 10001822 10001822 9b. Orifice Pilot PSE - Prop. 10001823 10001823 10a. Pilot Assembly SIT Top Convertible - Nat. 10002389 10002389 10b. Pilot Assembly SIT Top Convertible - Prop.
  • Page 20: Optional Accessories

    Gas Fireplace Insert Optional Accessories Follow the instructions supplied with the Zero Clearance Ceramic Refractory Kit carefully for proper installation. Optional for A125 and A132 Remote Controls Model Description Optional remote control units are available to control RHE25CR Ceramic Firebox Liner different functions of the appliance.
  • Page 21: Trim Assembly

    38" W (673mm x 965mm). LP trim dimensions are for openings smaller than 29" H x 41" glass trim top W (736mm x 1040mm). 2/03 A2 HE25FP Trim For use with A125 Bottom Decorative HE25FP Flat face louvres with polished window Plate...
  • Page 22 Fasteners Package (Not Shown) 57916 KT207 Bay Front A3 HE25BTKP attach fan control box HEDV30/HEDV32 For use with A125 3/19/01 djt HE25BTKP Bay window kit with polished brass trim Do not remove existing glass with frame. Extension Knobs KT204a Trim Assembly Fig.
  • Page 23 Gas Fireplace Insert HE25BTKP Replacement Parts FP1270 Fig. 33 Bracket for HEBTKP. 0801 KT210a CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products Fig. 34 Hang the window grille or the steel frame onto the at any time, without notice.
  • Page 24: Frame Assembly

    Gas Fireplace Insert A4 Riser Kits 10/24 Screws For use with A125 Frame Top 1. Install the unit according to Homeowner’s Manual. 2. Install the trim according to Installation Instructions. 3. Remove the two (2) screws at the bottom of the trim.
  • Page 25 Gas Fireplace Insert 4. Install the trim top deflector and fasten it (will hold Frame Mounting the inner top piece). Use two (2) screws to assemble General Information them. 5. Install trim channels (left and right sides). Use two The Decorative Front Frame should be installed last (2) screws to assemble each piece.
  • Page 26 Gas Fireplace Insert RHESS, RHESL, RHESSD, RHESLD, RHESXL Trim Replacement Parts IMPORTANT: Only trim panel assemblies ap- proved by CFM Corporation can be used on these products. ALL repair parts will be available from your local dealer. When ordering, always give the following informa- tion: Model and serial number, part description with finish and part number.
  • Page 27 Gas Fireplace Insert A4 Riser Kits Trim Kit For use with A125 1. Install the unit according to Homeowner’s Manual. 2. Install the trim according to Installation Instructions. 3. Remove the two (2) screws at the bottom of the trim.
  • Page 28 Gas Fireplace Insert 10002964...
  • Page 29 Gas Fireplace Insert 10002964...
  • Page 30 Gas Fireplace Insert 10002964...
  • Page 31: Warranty

    LIMITED LIFETIME WARRANTY Gas Fireplace Insert PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) •...
  • Page 32 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com...

This manual is also suitable for:

A132A132rn

Table of Contents